• Title/Summary/Keyword: Distance window

Search Result 217, Processing Time 0.029 seconds

A plan for a renewal design of an inner shop at a department store (대형백화점의 B 브랜드 리뉴얼 계획안)

  • Kim, Hye-Ja
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.221-222
    • /
    • 2005
  • Nowadays, the consuming society, the quality of wideness is increasing as the economic life level increases. Modern's any of large department stores, playing a very important role in the middle of our consuming culture, is creating a new life culture and life patterns including producing a new consuming value, too. This is a plan for a renewal design of an inner shop at a department store for brand launching in Seoul, which was planed to escape from the brand's own cold color to show up the product's color using indirect illumination. It was also considered clients' path lines who may keep at a distance to come into an expensive brand's store by designing the whole area as a show room, so there a window display and a harmony with the products let the shop be well functionalized.

  • PDF

On-Line Estimation of Partial Discharge Location in Power Transformer

  • Yoon, Yong-Han;Kim, Jae-Chul;Chung, Chan-Soo;Kwak, Hee-Ro;Kweon, Dong-Jin
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.2
    • /
    • pp.45-51
    • /
    • 1996
  • This paper presents a neural network approach for on-line estimation of partial discharge(PD) location using advanced correlation technique in power transformer. Ultrasonic sensors detect ultrasonic signals generated by a PD and the proposed method calculates time difference between the ultrasonic signals at each sensor pair using the cross-correlation technique applied by moving average and the Hamming window. The neural network takes distance difference as inputs converted from time difference, and estimates the PD location. Case studies showed that the proposed method using advanced correlation technique and a neural network estimated the PD location better than conventional methods.

  • PDF

Image Restoration of Remote Sensing High Resolution Imagery Using Point-Jacobian Iterative MAP Estimation (Point-Jacobian 반복 MAP 추정을 이용한 고해상도 영상복원)

  • Lee, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.6
    • /
    • pp.817-827
    • /
    • 2014
  • In the satellite remote sensing, the operational environment of the satellite sensor causes image degradation during the image acquisition. The degradation results in noise and blurring which badly affect identification and extraction of useful information in image data. This study proposes a maximum a posteriori (MAP) estimation using Point-Jacobian iteration to restore a degraded image. The proposed method assumes a Gaussian additive noise and Markov random field of spatial continuity. The proposed method employs a neighbor window of spoke type which is composed of 8 line windows at the 8 directions, and a boundary adjacency measure of Mahalanobis square distance between center and neighbor pixels. For the evaluation of the proposed method, a pixel-wise classification was used for simulation data using various patterns similar to the structure exhibited in high resolution imagery and an unsupervised segmentation for the remotely-sensed image data of 1 mspatial resolution observed over the north area of Anyang in Korean peninsula. The experimental results imply that it can improve analytical accuracy in the application of remote sensing high resolution imagery.

3-D Object Tracking using 3-D Information and Optical Correlator in the Stereo Vision System (스테레오 비젼 시스템에서 3차원정보와 광 상관기를 이용한 3차원 물체추적 방법)

  • 서춘원;이승현;김은수
    • Journal of Broadcast Engineering
    • /
    • v.7 no.3
    • /
    • pp.248-261
    • /
    • 2002
  • In this paper, we proposed a new 3-dimensional(3-D) object-tracking algorithm that can control a stereo camera using a variable window mask supported by which uses ,B-D information and an optical BPEJTC. Hence, three-dimensional information characteristics of a stereo vision system, distance information from the stereo camera to the tracking object. can be easily acquired through the elements of a stereo vision system. and with this information, we can extract an area of the tracking object by varying window masks. This extractive area of the tracking object is used as the next updated reference image. furthermore, by carrying out an optical BPEJTC between a reference image and a stereo input image the coordinates of the tracking objects location can be acquired, and with this value a 3-D object tracking can be accomplished through manipulation of the convergence angie and a pan/tilt of a stereo camera. From the experimental results, the proposed algorithm was found to be able to the execute 3-D object tracking by extracting the area of the target object from an input image that is independent of the background noise in the stereo input image. Moreover a possible implementation of a 3-D tele-working or an adaptive 3-D object tracker, using the proposed algorithm is suggested.

ABSOLUTE DIMENSIONS OF CONTACT BINARY STARS IN BAADE WINDOW (바데의 창 영역에서 발견된 접촉형 쌍성의 절대량)

  • 강영운
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.217-266
    • /
    • 1999
  • The light curves of the representative 6 contact binary stars observed by OGLE Project of searching for dark matter in our Galaxy have been analyzed by the method of the Wilson and Devinney Differential Correction to find photometric solutions. The orbital inclinations of these Devinney Differential Correction to find photometric solutions. The orbital inclinations of these binaries are in the range of $52^{circ}-69^{\circ}$ which is lower than that of the solar neighborhood binaries. The Roche lobe filling factor of these binaries are distributed in large range of 0.12 - 0.90. Since absence of spectroscopic observations for these binaries we have found masses of the 6 binary systems based on the intersection between Kepler locus and locus derived from Vandenberg isochrones in the mass - luminosity plane. Then absolute dimensions and distances have been found by combining the masses and the photometric solutions. The distances of the 6 binary systems are distributed in the range of 1 kpc- 6 kpc. This distance range is the limiting range where the contact binaries which have period shorter than a day are visible. Most contact binaries discovered in the Baade window do not belong to the Galactic bulge.

  • PDF

Distance and Probability-based Real Time Transmission Scheme for V2V Protocol using Dynamic CW allocation (V2V 프로토콜에서 실시간 전송을 위한 동적 CW 할당 기법)

  • Kim, Soo-Ro;Kim, Dong-Seong;Lee, Ho-Kyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.80-87
    • /
    • 2013
  • This paper proposes a CW (Contention window) allocation scheme for real-time data transmission of emergency data on VANET (Vehicle to vehicle Ad hoc Network, V2V) protocol. The proposed scheme reduces the probability of packet collisions on V2V protocol and provides bandwidth efficiency with short delay of emergency sporadic data. In the case of high density traffic, the proposed scheme provides a decrease of recollision probability using dynamic CW adjustments. For the performance analysis, a throughput, end-to-end delays, and network loads were investigated on highway traffic. Simulation results show the performance enhancements in terms of the throughput, end-to-end delays, and network loads.

Steel Plate Thickness Gauge by means of Gamma-Ray Backscattering (감마선 빽스켓터링을 이용한 철판 두께 측정에 관하여)

  • 김덕진;김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.1
    • /
    • pp.18-23
    • /
    • 1966
  • An experimental study of a steel plate thickness gauge by means of the measurements of backscatered gamma-rays has been carried out. The difference between this and other methods is that this method does not include any shilding matterials in the detecting probe, because the primary radiations and the backscattered radiations are detected simultaneously by an NaI (TI) scintillating crystal, and the activity of the Co-60 source used is low enough. In this thickness gauge, the thickness of the steel plates can be read directly on the counting ratemeter scale. The optimum conditions in the source-to-detector distance, window width of the analyzer, energy and strength of the gamma-ray source were found experimentally. The results have shown that the accuracy of the gauge was about $\pm$3% in the range of 3 to 8mm thickness. This gauge can be used to detect the pits or corrosions on the inner walls of the steel pipes.

  • PDF

Slective Buffering Macro Handover Which Applies The F-SNOOP in Hierarchical structure (계층 구조에서 F-SNOOP을 적용한 선택적 버퍼링 매크로 핸드오버)

  • Ahn Chi-Hyun;Kim Dong-Hyun;Kim Hyoung-Chul;Ryou Hwang-Bin;Lee Dae-Young;Jun Kye-Suk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.5B
    • /
    • pp.413-420
    • /
    • 2006
  • HMIPv6 is designed to reduce the signaling load to external network and improve handover speed of MN by including Mobility Anchor Point(MAP) in local handover. However in this case of macro handover, it's just used pervious MIPv6 handover algorithm. So, it occurs packet loss and transmission delay problem. In this paper, we propose the mechanism applying the HMIPv6 for Fast Handover to choose suitable to the condition buffering handover. The condition for the selection is result distance measurement between MN and CN, between MN and NAR. Furthermore, using F-SNOOP protocol, it is possible to improve wireless network performance. Wireless network has high Bit Error Rate(BER) characteristic because of path loss, fading, noise and interference. TCP regards such errors as congestion and starts congestion control. This congestion control makes packet transmission rate low. However, F-SNOOP improves TCP performance based on SNOOP and Freeze TCP that use Zero Window Advertisement(ZWA) message when handoff occurs in wireless network.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Development of a Microwave Level Meter Using YIG-VCO for Industrial Process (YIG-VCO를 사용한 산업용 마이크로파 거리계의 개발)

  • 김정목;임종수;전중창;김태수;안광호;이승학
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2000
  • In this paper, we have designed a microwave level meter based on the FM-CW radar theory using a YIG-tuned oscillator (YTO). YTO has an excellent frequency linearity, so a linearizer circuit is not necessary for the level meter. It is shown that interference signals reflected from nearby obstacles can be removed by using a digital band-pass filter. An FIR band-pass filter is designed using the Kaiser window. The distance measurement has been performed in the outdoor test field. The measurement data have been obtained for the range of 1~40m with 1m step, and the results show that the standard deviation of the measured data is 2.33 cm. The level meter manufactured in this study can be applied usefully in the industrial facilities which are not accessible easily, for example, to measure the level of molten metal in the iron and steel company.

  • PDF