• Title/Summary/Keyword: Distance measuring system

Search Result 446, Processing Time 0.035 seconds

Design Concept of e-Learning System based on Cybernetics

  • Matsumoto, Tsutomu;Ohtsuka, Hirofumi;Shimada, Yasuyuki;Kawaji, Shigeyasu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2424-2429
    • /
    • 2003
  • The importance of e-Learning, which supports to study anywhere and anytime, has been pointed out for improving education. There have been various research papers on e-Learning system for educations. Most of literatures have focused on guiding the student or measuring understanding their level etc. Design method of e-Learning system has not been discussed based on structure and analysis of the class. In this paper, scheme of the class is proposed by analyzing and structuring class, then design method of e-Learning system is discussed based on it.

  • PDF

Development of an Internal Measurement System for the Footwear using Laser Sensor (레이저 센서를 이용한 신발 내측 측정장치 개발)

  • 이지용;김민주;이승수;박재덕;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.281-284
    • /
    • 2004
  • This paper presents studies on the development of an internal measurement system for the footwear using laser sensor. The measurement system gains to the height of the profile at internal footwear. It accomplishes the 3-axises control which uses ball screws, L-M guides and stepping motors. It is used a laser sensor at the measurement of the distance, and Labview is used for the control and the measurement. We can get the profile through reverse engineering for the LAST. The data of profile is fixed a heigh of the LAST. Then, we try to verify as compare the profile with one which is collected by Internal measurement system..

  • PDF

Snow-Falling Measurement System monitoring the Height of Snow using the Photo Coupler (포토카플러를 이용한 눈(snow)높이 감지 강설 계측시스템)

  • 최만용;박해원;박정학;김원태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.517-520
    • /
    • 2003
  • The snow-fatting measurement system including the snow sensor applying the photo-coupler is investigated in this study and using this snow sensor the height of snow fallen is measured. To measure the snow depth, five photo sensors are arranged with 5 mm distance. The snow-falling measurement system, which is measuring the motor revolution controlled with stepping motor, is mounted above the snow surface. From this work, it is feasible to measure quantitatively the snow on real time. Its software implements a proven method to achieve valid measurements also under difficult conditions as future study. In cases where the snow sensor is applieded to the prediction of snow in the meteorological observation system and the snow removing system, it is recommend the GRS-Option in order to improve the quality of snow measurements for better compensation.

  • PDF

A Study of Development of a Remote Monitoring Data Acquisition System using TCP/IP Protocol (TCP/IP Protocol을 이용한 원격 감시용 계측 시스템 개발에 관한 연구)

  • 문경록;이주열;김재문
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.173-176
    • /
    • 2002
  • DAS(Data Acquisition System) as a ground support equipment has played a critical role in proving the status of ready-to-fire of a rocket system before launch. But it is hard to implement and place a real-time measuring system in a control room at a long distance from the vehicle. In this paper DAS is introduced by being located at the LEC(Launch Equipment Container)[1], 50 meters away from the rocket and connected to remote monitoring system via fiber optics with TCP/IP protocol by means of client/server algorithm. Therefore real-time data acquisition and storage are guaranteed and a convenient and useful MMI (Man-Machine Interface) can be developed.

  • PDF

A RADAR SYSTEM TO DETECT SOIL SURFACE UNDER PLANT/VEGETATION

  • Shin, B.;R.B.Dodd;Han, Y.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.363-372
    • /
    • 1993
  • For more accurate height/depth control of the agricultural implements , the soil surface as a reference position should be measured as accurate as possible. A new measurement system using microwave was developed to detect the true soil surface even under plant and/or vegetation. Two-frequency continuous-wave radar was used as the measurement system. It could estimate the distance to the target by measuring the phase difference between two different frequencies continuous-waves which reflected on the target surface. The system performance was evaluated on the barely field where the average height of barley was 91.5 cm. The experimental results showed that the system performance was not affected by the existence of barely. The maximum measurement errors were 8.91 com and 8.44cm for two different experimental plots.

  • PDF

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.

A Study on the Strain Measurement of Structure object by Electronic Process and Laser Interferometry (전자처리 및 Laser간섭에 의한 구조물의 Strain 측정에 관한 연구)

  • Jung, W.K.;Kim, K.S.;Yang, S.P.;Jung, H.C.;Kim, J.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.40-49
    • /
    • 1995
  • This paper presents the performance and problems in analysis method and testing system of Electronic Speckle Pattern Interferometry (ESPI) method, in measuring two - dimensional in-plane displacement. The anyalysis result of measurement by ESPE is quite comparable to that tof measurement by strain gauge method. This implies that the method of ESPE is a very effective tool in non-contact two-dimensional in-plane strain analysis. But there is a controversal point, measurment error. This error is discussed to be affected not by ESPE method itself, but by its analysis scheme of the interference fringe, where the first-order interpolation has been applied to the points of strain measured. In this case, it is turned out that the more errors would be occurred in the large interval of fringe. And so this paper describes a computer method for drawing when the height is available only for some arbitrary collection of points. The method is based on a distance-weighted, last- squares approximation technique with the weight varying with the distance of the data points.

  • PDF

Data Envelopment Analysis for Container Terminals Considering an Undesirable Output - Focus on Busan Port & Kwangyang Port (유해산출물을 고려한 국내 컨테이너 터미널 효율성 분석)

  • Shin, Chang-Hoon;Jeong, Dong-Hun
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.195-201
    • /
    • 2013
  • Recently according to increase of enlarged scale ports in conformity with increase in over size vessels and container handling service, pollutants generated from ports are increasing. In advanced countries, reduction in carbon dioxide emission assigned to them has been implemented according to the Climate Change Convention and Kyoto Protocol from 2008 to 2012 in order to lessen carbon dioxide emission. Henceforth increase in discussion on the measure of constructing Green Port and low-carbon port is expected in our nation's field of port as well, it is considered that the effort in reduction with regard to undesirable output which causes environmental problem of analysis target during measuring effectiveness. Therefore, in this study, effectiveness was estimated through directional technology distance function considering undesirable output differently from effectiveness analysis of existing container terminal, and then performed comparative analysis with the result analyzed with BCC output-oriented model. As the result of analysis, in 2007 DMU3 and DMU5, and in 2010 DMU2 and DMU4 appeared to be efficient terminals in BCC output oriented model, and in directional technology distance function model, DMU1, DMU3 in 2007, DMU3, DMU5 in 2008, DMU7 in 2009, and DMU2, DMU5 in 2010 appeared to be efficient terminals.

Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline (60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구)

  • Hong, Seung Cheol;Choi, Seong Ho;Kim, Yoon Shin;Park, Jae Young
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.4
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

Design and Development of Sprinkler Control System Utilizing Mobile with IoT

  • Kang, Tae-Sun;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.212-217
    • /
    • 2020
  • We studied on the design of a sprinkler control system that communicates with the administrator's mobile through a wireless communication network and a sprinkler unit that sprays water on the vegetation area. This sprinkler control system consists of a communication module that receives an operation signal for the operation of the sprinkler unit from the administrator's mobile, and a control module that controls the sprinkler unit according to the operation signal received through the communication module. It is also designed to control sprinkler units by measuring temperature, humidity, light intensities, vibration and field images in the vegetation area in real time through sensors and camera for each of them and comparing them with established limit criteria. The sprinkler allows the administrator to control the sprinkler more easily because the administrator operates the sprinkler through the mobile from a distance, and emergency situations occur and can respond quickly.