• Title/Summary/Keyword: Distance measuring system

Search Result 447, Processing Time 0.026 seconds

The Implementation of Remote Health Monitoring System using a Mobile Platform (모바일 플랫폼을 이용한 원격 건강 감시 시스템 구현)

  • Ryu, Geun Taek;Kim, Chang Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.379-385
    • /
    • 2012
  • This paper suggests U-healthcare system for individual health management realizing the gateway, client, and Java-based network server by using the vital signal measuring system and android-based mobile platform. This study realized the vital signal measuring system based on the technology to measure the ECG, oxygen saturation, blood pressure, and respiration, etc. And all the information of measurement was transmitted to the mobile gateway using the 3-bite transmission protocol consisting of headers and data. The data transmitted to the mobile gateway was used to examine the mobile client's personal health indexes through the network server. This paper realized and tested the android-based gateway, client, and the broadcasting network server and verified their validity with simulations and actual humans. As a result, the U-healthcare system suggested was proved to be effective in managing each individual's health from short distance and long distance. And it could examine each individual's health conditions in real-time and was found to be advantageous in that it could secure the guardian's mobility.

Measuring Inner or Outer Position of Ship Passenger and Detection of Dangerous Situations based LoRa WAN Communication (LoRa WAN 통신 기반의 선박 내/외부 승선자 측위 및 위험상황 감지 시스템)

  • Park, Seok Hyun;Park, Moon Su
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.2
    • /
    • pp.282-292
    • /
    • 2020
  • In order to minimize casualties from marine vessel accidents that occur frequently at home and abroad, it is important to ensure the safety of the passengers aboard the vessel in the event of an accident. There is an EPIRB system as a system for disaster preparedness in the marine situation currently on the market, but there is a problem that the price is very expensive. In order to overcome the cost problem, which is a disadvantage of previous system, LoRaWAN-based communication is used. LoRaWAN communication-based vessel positioning and risk detection system based on LoRaWAN communication transmits measurement data of each module using two Beacon and GPS modules to stably perform position measurement for both indoor and outdoor situations. The rider danger situation detection system can detect the safety status of the rider using the 3-axis acceleration sensor, collect data from the rider positioning system and the rider safety status detection system, and send to server using LoRa communication. When conducting communication experiments in the long-distance maritime situation and actual communication experiments using the implemented system, it was found that the two experiments showed over 90% communication success rate on average.

Estimate for Ensuring sight Distance of Curve Section from Consideration of the Environmental Impact Assessment based on the 3D GIS (3차원 GIS기법으로 환경영향을 고려한 곡선부 시거 안정성 분석)

  • Choi Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.4
    • /
    • pp.700-705
    • /
    • 2006
  • The latest system of GIS has been changing from 2 dimension to 3 dimension. According to the rapid growth of the fields linked to 3D GIS, 3D GIS has variously affected the public field, the national defense field. and the industrial field. This study estimated sight distance safety of curve section considering the environmental impact based on 3D GIS. Sight distance is calculated from the relation between road which keeps the three-dimension character and driver gaze, so it needs to consider both plane and vertical for the accurate measuring. This study made analysis of the sight distance through considering the environmental impact with driving simulation of design speed 80km/h and running speed 60-120km/h.

Luminance Correction Algorithm Based on Measuring Angle for the Portable Luminance Measurement System (휴대용 휘도측정시스템의 측정각도기반 휘도보정알고리즘)

  • Sun, Eun-Hey;Kim, Dongyeon;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.4
    • /
    • pp.321-326
    • /
    • 2016
  • In this paper, we propose a luminance correction algorithm based on measuring position for potable luminance measurement system. Measurement position and angle have an affect on the luminance value. We improve the position-based luminance measurement system using luminance correction algorithm based on the measuring angle. We analyze change of luminance value according to the measurement distance and angle from camera and light source. The certified point-luminance meter is used to evaluate a scene luminance measuring method using the image information of camera. Also, we derive an expression equation for evaluating luminance value from determined position. The performances of the proposed system are verified by using comparative experiments with the point-luminance meter using experimental signboard.

Flatness Control System of the Hot Strip by Using Tension Profile between Stands (스탠드간 장력프로파일을 이용한 열연판 평탄도 제어시스템)

  • 홍완기;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.27-36
    • /
    • 1999
  • To have high flatness quality of hot rolled strip in the hot strip finishing mill train, a new inter-stand tension profile measuring device of segmented looper roll type(coined as Flatness Sensing Inter-stand Looper, FlatSIL) and a new flatness control system have been developed in this study. The device measures the strip tension profile across the strip width and informs the strip wave pattern to new flatness control system where work roll bending mode to relieve the strip wave is determined. The existing automatic shape control system which uses laser type shape-meter installed at the outlet of the last finishing mill stand strip tension between down coiler and last finishig mill since the latent wave concealed by the strip tension between down coiler and last finishing mill stand cannot be measured by the laser distance-meter. Thus the existing shape control system is not able to control the flatness through the full strip length. The new flatness control system, however, works for full strip length during strip rolling as far as the tension profile measuring device and work roll bender are on. With the new flatness control system, work roll bender is automatically controller to minimize the latent wave of the running strip and the flatness quality as well as strip travelling stability has been noticeably improved from strip head through body to tail.

  • PDF

The development of indoor location measurement System using Zigbee and GPS (Zigbee와 GPS를 이용한 실내 위치 인식 시스템 개발)

  • Ryu, Jeong-Tak;Kim, In-Kyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • This paper proposes a new indoor location recognition system using a ZigBee network and a global positioning system(GPS). The proposed location recognition system applies GPS values that are mainly used for outdoor location recognition, to indoor location recognition; hence the techniques conventionally separated for the indoor and outdoor location recognition are integrated into one location recognition technique. The proposed system recognizes a location using the distance between nodes. Although the distance between nodes can be calculated by measuring the strength of the received ZigBee signals, generally the measured distance is not accurate and has high error rates since the strength of the ZigBee signals is different depending on the distance. In order to reduce the error rate, we have subdivided the output power of the received ZigBee signals into five levels. When a moving node generates a signal, each fixed node transmits the received signal strength and its own GPS information to other nodes, so the moving node can find its own accurate location in terms of the received signals.

The Phase Difference Measurement Module Development for Amplitude Modulated Range Measurement System (진폭 변조 거리 측정 시스템을 위한 정밀 위상차 측정부 개발)

  • Noh, Hyoung-Woo;Park, Jeong-Ho;Kang, Il-Heung;Choi, Mun-Gak;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.182-190
    • /
    • 2011
  • A amplitude modulation(AM) range measuring system utilizes the phase difference of the modulated envelope of the reflected signal to measure the distance. It is known that the AM system has a problem in accuracy due to antenna leakage signals and spurious reflection signals, but an AM range measurement system using an active reflector, which shifts the frequency bands, has been proposed in order to minimize the measurement errors due to spurious signals. In this paper, a new phase measurement module for the AM range measurement system, which enables to measure long distance with good accuracy, is proposed. The modulation frequency is alternatively selected between 8 and 1 MHz, and the measured distance range with this module is up to 150 m within 2 cm accuracy. A JK flip-flop circuit is used for higher phase accuracy, and an XOR circuit is used to cover long distance.

Evaluation of Errors Due to Earth Mutual Resistance in Measuring Ground Impedance of Vertically-driven Ground Electrode (수직 접지전극의 접지임피던스 측정에서 도전유도에 의한 오차 평가)

  • Choi, Jong-Hyuk;Choi, Young-Chul;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1778-1783
    • /
    • 2009
  • Ground impedance for the large grounding system is measured according to the IEEE Standard 81.2 which is based on the revised fall-of-potential method of installing auxiliary electrode at a right angle. When the auxiliary electrodes are located at an angle of $90^{\circ}$, the ground impedance inevitably includes the error due to earth mutual resistance. In this paper, in order to accurately measure the ground impedance of vertically-driven ground electrodes, error rates due to earth mutual resistance are evaluated by ground resistance and ground impedance measuring devices and compared with calculated values. As a result, the measured results are in good agreement with the computed results considering soil layer with different resistivity. The error rates due to earth mutual resistance decrease with increasing the length of ground electrode in the case that the ratio of the distance between the ground rod to be measured and the auxiliary electrodes to the length of ground electrode(D/L) is same. The ground impedance should be measured at the minimum distance between the auxiliary electrodes that will have an estimated measurement accuracy due to earth mutual resistance.

Noncontact 3-dimensional measurement using He-Ne laser and CCD camera (He-Ne 레이저와 CCD 카메라를 이용한 비접촉 3차원 측정)

  • Kim, Bong-chae;Jeon, Byung-cheol;Kim, Jae-do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1862-1870
    • /
    • 1997
  • A fast and precise technique to measure 3-dimensional coordinates of an object is proposed. It is essential to take the 3-dimensional measurements of the object in design and inspection. Using this developed system a surface model of a complex shape can be constructed. 3-dimensional world coordinates are projected onto a camera plane by the perspective transformation, which plays an important role in this measurement system. According to the shape of the object two measuring methods are proposed. One is rotation of an object and the other is translation of measuring unit. Measuring speed depending on image processing time is obtained as 200 points per second. Measurement resolution i sexperimented by two parameters among others; the angle between the laser beam plane and the camera, and the distance between the camera and the object. As a result of these experiments, it was found that measurement resolution ranges from 0.3mm to 1.0mm. This constructed surface model could be used in manufacturing tools such as rapid prototyping machine.

Improved kinematic mount design for bar type reference mirror for profilometric measurement large optical surface

  • Jung, Kil-Jae;Yang, Ho-Soon;Rhee, Hyug-Gyo;Jyun, Byoung-Hyug;Lee, Yun-Woo;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.25.3-25.3
    • /
    • 2010
  • Our previous study used a bar-type reference mirror to measure the relative distance to the target surface. The target measurement accuracy was required to $1{\mu}m$ PV for aspheric optical surface up to 1m in diameter. Earlier system suffers from the reference surface deformation when the measuring part moves. In order to reduce the deformation, measuring part and the reference part separated from each order in the new design. This system utilizes a kinematic support assembly using invar flexure to minimize the reference surface deformation under gravity and vibration. The surface deformation requirement of reference mirror is defined as of $0.2{\mu}m$ under gravity and 40Hz vibration. The finite element results, shows reference mirror deformation of $0.164{\mu}m$. The first resonance mode was computed to analysis 46.05Hz for reference part and 43.44Hz for measuring part. Thesis satisfies the frequency requirement.

  • PDF