• 제목/요약/키워드: Distance Relaying Algorithm

검색결과 56건 처리시간 0.029초

765kV 비연가 송전선로에서 단상지락고장 시어 거리개전 알고리즘 (A New Distance Relaying Algorithm for Phase-to-Ground Fault in 765kV Untransposed Transmission Lines)

  • 안용진;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.452-454
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-ground fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for Phase-to-ground fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

765kV 비연가 송전선로에서 상간단락고장 시어 거리계전 알고리즘 (A New Distance Relaying Algorithm for Phase-to-Phase Short Fault in 765kV Untransposed Transmission Lines)

  • 안용진;강상회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.455-457
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-phase short fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-phase short fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kv untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

주파수 특성을 고려한 송전선 보호용 적분근사거리계전 알고리즘의 최적 적분 계수 결정 (Optimal Solution of integral Coefficients in Distance Relaying Algorithm for T/L Protection considering Frequency Characteristics)

  • 조경래;홍준희;정병태;조정현;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.42-44
    • /
    • 1994
  • This paper presents the method of estimating integral coefficients of new distance relaying algorithm for transmission line protection. The proposed method is based on the differential equation calculates impedance value by approximation of integral term of integro-differential equation which relate voltage with current. As a result, we can determine the integral coefficients in least square error sense in frequency domain and we take into consideration the analog filter characteristics and frequency domain characteristics of the system to be protected. The simulation results showed that these coefficients can be successfully used to obtain impedance value in distance relay.

  • PDF

진행파 기법을 이용한 새로운 초고속 거리계전 방식 (A New Ultra High Speed Distance Relaying Method Using Travelling Wave Technique)

  • 강상희;박종근
    • 대한전기학회논문지
    • /
    • 제40권12호
    • /
    • pp.1203-1210
    • /
    • 1991
  • This paper proposes a new distance relaying method based on fault initiated travelling waves for transmission line protection. The characteristics of this method are ultra high speed and excellent sensitivity. Travelling wave technique which is one of the distance relaying methods uses the discrete cross correlation function for discrimination between internal and external fault is remarkably reduced in case of a close up fault and an inception angle near or equal to zero fault. To cope with this problem, a new fast algorithm which uses backward wave summation method with fixed window is presented. The proposed method has been tested by numerical simulations using the EMTP.

  • PDF

반사계수 추정에 의한 초고속 거리계전 알고리즘 (Using Distance Relaying Algorithm Using Reflection Coefficients Estimation)

  • 정병태;조경래;홍준희;정해성;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.36-38
    • /
    • 1994
  • A novel UHS relaying algorithm using reflection coefficients estimation is proposed. Based on a travelling ware approach the algorithm can determine the fault location in a travelling time of the protected lone. The discrimation of the reflected wave from others is possible observing the difference of two coefficients. The algorithm is tested using results determined by EMTP.

  • PDF

DC-Offset 제거 기능을 향상시킨 거리계전 알고리즘 (A Distance Relaying Algorithm Using an Improved Technique for Removing DC-offset)

  • 노재근;강상희;남순열;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.118-120
    • /
    • 2001
  • This paper presents a distance relaying algorithm based on the Discrete Fourier Transform(DFT) for elimination of DC-Offset. When the DFT is applied to current signal. the real and imaginary parts of fundamental component consist of fundamental component itself and DC-Offset. The DC-Offset is calculated by four consecutive values of the imaginary components, so that the fundamental component can be accurately estimated. Performance evaluation is presented for A-phase ground faults on 154kV 80km overhead transmission line. The proposed algorithm is inspected by software simulation and hardware simulation.

  • PDF

Multi-Agent 송전계통 보호시스템에서의 새로운 거리계전 알고리즘 (A Novel Distance Relaying Algorithm in a Multi-Agent Protection System of transmission line)

  • 문현경;진보건;현승호;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.217-219
    • /
    • 2003
  • This paper presents a distance relaying algorithm for a transmission line protection with MAS. First, the voltage and fault current of the opposite side are represented as a function of those of the measuring end using source voltages of both ends. These voltages are assumed to be obtained from the transformers protecting agents, periodically in normal state. Then, the fault location expression, independent of fault resistance, is derived with voltage and current in only one end of faulted line used. The suggested algorithm is applied to a simple system with two power sources to show its effectiveness.

  • PDF

민감도지수를 기반한 적응형 거리계전방식 (Adaptive Distance Relaying Based on Sensitivity Factors)

  • 원한천;임성일;이승재;최면송;임성정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.60-61
    • /
    • 2006
  • An unwanted trip of backup distance relays often lead to a blackout. This paper presents investigation report on involvement of backup distance relays in the past blackouts and sensitivity-factor based algorithm to make a distinction between a fault and overload caused by line tripping. A preliminary idea to prevent deterioration of the situation due to unwanted trip of distance relays by utilizing the proposed algorithm is presented.

  • PDF

산술퓨리에변환 필터에 의한 디지털 거리계전알고리즘에 관한 연구 (A Study on the Digital Distance Relaying Algorithm based on Arithmetic Fourier Transform Filter)

  • 박규현;이기원;박철원;김철환;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.471-475
    • /
    • 1995
  • This paper deals with the aliasing problem minimized by using an analog low-pass prefilter have a sampling frequency of 18000 Hz is designed and describes to extract their fundamental frequency components by AFT filter. And them distance relaying algorithm based AFT filter is computational simple, good frequency response and fast convergence in calculation of system apparant impedance. We performed off-line simulation using data from EMTP.

  • PDF

전류 페이저를 이용한 송전선로 고장점 추정 알고리즘 (Estimation of Fault Location on Transmission Lines using Current Phasor)

  • 여상민;김철환
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2095-2100
    • /
    • 2009
  • Since most of the Extra High Voltage (EHV) transmission lines are untransposed and multi-circuits, errors are occurred inevitably because of the unbalanced impedances of the lines and so on. Therefore, a distance relaying algorithm applicable to the untransposed multi-circuits transmission lines needs to be developed. The proposed algorithm of fault location estimation in the paper uses the fundamental phasor to reduce the effects of the harmonics. This algorithm also analyzes the second-order difference of the phasor to calculate the traveling times of waves generated by faults. The traveling time of the waves generated by faults is derived from the second-order difference of the phasor. Finally, the distance from the relaying point to the faults is estimated using the traveling times. To analyze the performance of the algorithm, a power system with the EHV untransposed double-circuit transmission lines are modeled and simulated under various fault conditions such as several fault types, fault locations, fault inception angles and fault resistances. The results of the simulations show that the proposed algorithm has the capability to estimate the fault locations quickly and accurately.