• 제목/요약/키워드: Distance Instrument

검색결과 165건 처리시간 0.026초

Operating Voltage of Optical Instruments based on Polymer-dispersed Liquid Crystal for Inspecting Transparent Electrodes

  • Yeo, Sunggu;Oh, Yonghwan;Lee, Ji-Hoon
    • Current Optics and Photonics
    • /
    • 제1권1호
    • /
    • pp.45-50
    • /
    • 2017
  • Optical instruments based on polymer-dispersed liquid crystal (PDLC) have been used to inspect transparent electrodes. Generally the operating voltage of an inspection instrument using PDLC is very high, over 300 V, reducing its lifetime and reliability. The operating-voltage issue becomes more serious in the inspection of touch-screen panel (TSP) electrodes, due to the bezel structure protruding over the electrodes. We have theoretically calculated the parameters affecting the operating voltage as a function of the distance between the TSP and the PDLC, the thickness, and the dielectric constant of the sublayers when the inspection module was away from the TSP electrodes. We have experimentally verified the results, and have proposed a way to reduce the operating voltage by substituting a plastic substrate film with a hard coating layer of smaller thickness and higher dielectric constant.

엘리트 육상선수와 태권도 선수의 등속성 운동능력에 관한 비교 연구 (Isokinetic Strength Capacity Between Elite Athletes and Taekwondo Player)

  • 김현미;이소윤
    • 한국산학기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.2691-2697
    • /
    • 2011
  • 본 논문은 대학교 육상단거리 선수와 태권도 선수의 근력, 근 파워를 비교하기 위하여 등속성 근력검사기기를 이용하여 기초체력, 슬관절의 근력($60^{\circ}$/sec), 근 파워($180^{\circ}$/sec)를 분석하여 육상 단거리 선수와 태권도 선수의 근기능 특성을 밝히고자 하는데 목적으로 수행되었다. 기초체력은 육상 단거리 선수가 태권도 선수에 비해 높게 나타났으며, 기초체력 중 좌악력과 순발력에서 통계적으로 높게 나타났다. 슬관절의 근력은 육상 단거리 선수가 태권도 선수에 비해 높게 나타났으나, 근 파워에서는 태권도 선수가 육상 단거리 선수에 비해 통계적으로 차이가 높게 나타났다. 이와 같은 결론을 종합해 볼 때, 육상 단거리 선수와 태권도 선수는 근력뿐만이 아니라 순발력을 필요로 하고 있으며, 등속성 근 기능의 측정에서는 태권도 선수는 체중조절을 요구하는 경기의 특성 때문인지 평균파워와 체중당 평균파워에서만 통계적으로 높게 나타났다. 그러므로 차후 연구에서는 각각의 운동 종목별 근 기능을 분석을 하는 것이 필요한 실정이며, 태권도 선수와 유사한 특성을 가진 투기종목에서도 근 기능을 분석하는 연구가 필요 할 것으로 사료된다.

적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정 (Distance Measurement of Small Moving Object using Infrared Stereo Camera)

  • 오준호;이상화;이부환;박종일
    • 전자공학회논문지SC
    • /
    • 제49권3호
    • /
    • pp.53-61
    • /
    • 2012
  • 본 논문에서는 스테레오 적외선 카메라를 이용하여 소형 및 고온으로 날아가는 이동체의 거리를 실시간으로 측정하는 시스템을 제안한다. 이동체와 주변 환경의 온도 차이를 측정하고 고속으로 이동하는 소형 이동체의 거리를 자동으로 측정하기 위하여 적외선 스테레오 카메라 시스템을 구축하였다. 우선 적외선 카메라를 이용하여 취득한 고온의 이동체 영상으로부터 주변의 온도분포와 이동체간의 온도차를 이용하여 이동체영역을 검출하고, 이동체의 움직임 정보와 적외선 카메라 영상의 밝기정보를 결합하여 이동체를 추적한다. 좌우 적외선 카메라 영상에 대하여 각각 추출된 이동체 영역을 중심으로 스테레오 정합을 수행하여 시차정보를 추정하고, 카메라 파라미터와 시차정보를 이용하여 실시간으로 이동하는 이동체의 거리를 추정한다. 본 논문에서 제안하는 적외선 스테레오 카메라 시스템을 검증하기 위하여 고온의 이동체를 촬영할 때, 3차원 궤적(x,y,z) 측정기를 함께 가동하여 이동체가 이동하는 거리를 측정하여 이를 기준 거리(ground truth)로 설정하였다. 3차례의 비디오 데이터로부터 실험한 결과, 적외선 스테레오 카메라를 이용한 고온/소형 이동체의 거리오차 측정 결과는 평균적으로 9.68%로 추정되었다. 스테레오 적외선 카메라의 타이밍 문제(jitter)를 고려하면, 실제로 추정 오차는 줄어들 것으로 판단되기 때문에, 향후 적외선 카메라를 이용하는 다양한 이동체의 거리 및 위치를 측정하는데 응용할 수 있을 것으로 기대된다.

지형측량을 위한 무 프리즘 토털스테이션 정확도 평가 (Accuracy Evaluation of Non-prism Total Station for Topographic Surveying)

  • 서동주
    • 한국측량학회지
    • /
    • 제24권5호
    • /
    • pp.433-441
    • /
    • 2006
  • 최근 전자기술의 발달로 대상물에 접촉하지 않고, 장비에서 발사된 레이저가 측정대상물에 직접 반사되어 거리를 측정 가능하게 하였다. 더욱이 3차원위치를 결정할 수 있는 무 프리즘 토털스테이션이 등장하여 도로, 공항, 항만 등의 토목분야 뿐 아니라 구조물변위, 계측 등의 건축분야에 그 활용이 증대되고 있다. 따라서 본 연구에서는 무 프리즘 토털스테이션의 정확도를 평가하기 위하여 관측거리에 따른 재료 및 반사각도별로 관측하여 정확도를 분석하였고, 그 활용성을 위하여 지형측량에 적용하였다. 연구한 결과는 무 프리즘 토털스테이션은 반사각도가 $90^{\circ}$일 때는 재료와 상관없이 매우 양호한 값으로 분석되었다, 점차적으로 반사각도가 예각으로 증가할 때 RMSE는 높아지는 양상이 보였다. 그리고 관측거리에 따른 재료 및 반사각도별로 회귀분석 한 결과, 관측거리와 반사각도는 상관성이 있는 것으로 판단되며, 재료와는 상관성이 없는 것으로 분석되었다. 일반적인 지형측량에 있어서 무프리즘 토털스테이션을 적절히 활용한다면, 교통의 흐름이 많은 곳의 도로, 경사각이 높은 암벽의 절리면, 기타 위험지역에서 측량자의 안전과 신속한 측량작업을 제공할 것으로 판단된다.

블랙박스 영상 분석을 통한 차량 충돌 속도 연산 알고리즘에 대한 융복합 연구 (An Estimating Algorithm of Vehicle Collision Speed Through Images of Blackbox)

  • 고광호
    • 디지털융복합연구
    • /
    • 제16권9호
    • /
    • pp.173-178
    • /
    • 2018
  • 에어백이 작동되는 중고속 추돌 사고의 경우 에어백 작동 전후의 차량 데이터가 차량의 EDM(Event Driven Memory)에 저장되어 그 추돌 속도를 쉽게 알 수 있다. 하지만 에어백이 작동하지 않는 저속영역에서 추돌하는 경우 그 속도를 산정하기가 어렵다. 또한 저속이라 하더라도 추돌속도에 따라 운전자의 부상 정도가 크게 영향을 받기 때문에 그 속도의 산정이 중요하다. 본 연구에서는 블랙박스에 저장된 영상 이미지를 분석하여 저속영역의 추돌속도를 연산하는 알고리즘을 제안하였다. 전기모터로 와이어로프를 이용하여 차량을 견인하는 방식으로 저속의 후방추돌 상황을 정확하게 재현하면서 다양한 차종과 속도에 대해 실험을 수행하였다. 이 때 블랙박스의 영상 이미지에서 두 차량의 거리가 좁아지는 비율과 전방 차량의 번호판 길이가 증가하는 비율이 동일함을 이용하여 추돌속도를 정밀하게 계산할 수 있다. 즉, 미리 측정된 초기거리와 블랙박스의 영상에서의 번호판의 길이를 초기조건으로 설정하여 본 연구의 계산 알고리즘을 적용하면 저속 추돌 속도를 정확하게 산정할 수 있다. 직선 추돌사고에는 본 연구의 결과가 그대로 적용되지만 각도를 두고 추돌하는 경우에는 별도의 고려가 필요하다.

Impaired Voluntary Wheel Running Behavior in the Unilateral 6-Hydroxydopamine Rat Model of Parkinson's Disease

  • Pan, Qi;Zhang, Wangming;Wang, Jinyan;Luo, Fei;Chang, Jingyu;Xu, Ruxiang
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권2호
    • /
    • pp.82-87
    • /
    • 2015
  • Objective : The aim of this study was to investigate voluntary wheel running behavior in the unilateral 6-hydroxydopamine (6-OHDA) rat model. Methods : Male Sprague-Dawley rats were assigned to 2 groups : 6-OHDA group (n=17) and control group (n=8). The unilateral 6-OHDA rat model was induced by injection of 6-OHDA into unilateral medial forebrain bundle using a stereotaxic instrument. Voluntary wheel running activity was assessed per day in successfully lesioned rats (n=10) and control rats. Each behavioral test lasted an hour. The following parameters were investigated during behavioral tests : the number of running bouts, the distance moved in the wheel, average peak speed in running bouts and average duration from the running start to the peak speed. Results : The number of running bouts and the distance moved in the wheel were significantly decreased in successfully lesioned rats compared with control rats. In addition, average peak speed in running bouts was decreased, and average duration from the running start to the peak speed was increased in lesioned animals, which might indicate motor deficits in these rats. These behavioral changes were still observed 42 days after lesion. Conclusion : Voluntary wheel running behavior is impaired in the unilateral 6-OHDA rat model and may represent a useful tool to quantify motor deficits in this model.

광신호의 공간 해상도 향상을 위한 초 분해능 알고리즘 연구 (A Study on Super Resolution Algorithm to Improve Spatial Resolution of Optical Signals)

  • 이병진;유봉국;김경석
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.71-77
    • /
    • 2018
  • 현재 설치된 광섬유의 문제를 모니터링 하는데 가장 널리 사용되는 방법은 Optical Time Domain Reflectometer(OTDR)이다. OTDR는 FTTx 네트워크를 테스트하기 위해 설계된 계측기이며, 전송 손실 및 접속 손실과 같은 광섬유의 물리적 특성을 평가한다. OTDR을 이용하여 광로상의 문제점을 정확히 파악하기 위해서는 Spatial resolution을 높이는 것이 중요하다. 펄스폭이 두 반사체 사이의 거리 두 배보다 작을 때는 두 반사체에서 반사되는 신호는 상호간에 겹침 없이 반사되므로 반사되는 신호의 구분이 가능하지만 펄스폭이 두 반사체 사이의 거리 두 배보다 클 때에는 두 반사 펄스가 겹쳐져 반사되는 신호가 구분되지 못한다. 이와 같은 한계를 극복하기 위해서 본 논문에서는 초 분해능 알고리즘을 적용하여 Spatial resolution 향상 방법을 제안하였으며, 시뮬레이션 결과, 초 분해능 알고리즘 적용 시에 분해능이 향상 되어 이벤트 구간을 더 정밀하게 분석할 수 있었다.

얼굴스캐너를 활용한 안면형상 영상진단기의 기초 연구 (Basic Study on the Image Instrument of the Facial-form by the 3D-facial Scanner)

  • 김경철;이정원;김훈;신순식;이해웅;이용태;지규용;김종원
    • 동의생리병리학회지
    • /
    • 제22권2호
    • /
    • pp.497-501
    • /
    • 2008
  • 3D facial scanner for an accurate analysis is measured precisely a distance in straight, a distance in curved line, an angle in 3D data, the area of surface. We can easy acquire 3D data by the method of 0.8sec in each scan with easy handling, simple merge to whole face, harmless and fast process. In the HyungSang medicine, the inspection of the facial shape includes the Dam(gall bladder) - Bang Kwang(urinary bladder) body, the Jung${\cdot}$Gi${\cdot}$Shin${\cdot}$Hyul, the six merdian types etc. And we will collect the evidence based date verifing in the HyungSang clinical medicine. As we will analyze the facial whole form and the size${\cdot}$length${\cdot}$angle of the facial part, put the facial form's standardization on a solid foundation.

유비쿼터스 환경의 원격교육을 위한 저작도구의 개발 (The Development of Authoring Tool for Distance Education of Ubiquitous Environment)

  • 김치수;임재현
    • 정보교육학회논문지
    • /
    • 제8권3호
    • /
    • pp.365-372
    • /
    • 2004
  • 본 논문은 자체 에디터가 포함된 벡터 기반의 원격교육시스템(FVU)을 개발함으로써 컨텐츠 제작의 편의성을 높이고, 보다 효율적으로 원격교육 매체를 제작할 수 있는 저작도구를 만들고자 하였다. 본 논문에서는 UML을 이용하여 저작도구를 설계하였으며 FVU라 명명하였다. FVU의 VUEditor에서는 강의에 필요한 첫 화면을 구성할 수 있으며, 이렇게 제작된 강의안은 Vector변환을 통해서 VUAuthor로 익스포트(Export)함으로써 파일 사이즈를 감소시키며, 낮은 대역폭을 형성하게 한다. 또한 교수자는 VUEditor에서 이미지 삽입, 도형 그리기, 텍스트 입력, 지우기 등의 작업을 할 수 있으며, VUAuthor에서 교재 제작 과정 중 잘못 그려진 선, 도형 등을 수정할 수도 있도록 설계되었다. 이러한 설계는 결과적으로 이미지 툴이나 파워포인트와 같은 응용 프로그램이 없어도 강의에 필요한 첫화면을 VUEditor 자체적으로 구성할 수 있도록 하였으며, 교수자의 컨텐츠 제작에 편의성을 향상시켰으며, 결과 파일의 크기가 작아지므로 유비쿼터스 무선 환경에서의 원격교육에 적합하도록 네트워크 트래픽의 문제를 다소 해결하였다.

  • PDF

두경부 위치에 따른 하악운동 및 측두하악관절음의 변화 (Changes of Mandibular Movement and TMJ Sound on Head and Neck Posture)

  • 나홍찬;최종훈;김종열
    • Journal of Oral Medicine and Pain
    • /
    • 제22권1호
    • /
    • pp.95-109
    • /
    • 1997
  • The purpose of this research is to investigate the influence on mandibular movements and TMJ sounds with changes of head and neck posture. For the research, twenty patients who had complained of TMJ sounds without any other symptoms of cranio-mandibular disorders, were selected as subjects for measurements of TMJ sounds, and radiographs on transcranial view of TMJ were taken on ten of the subjects. From NHP, UHP, DHP and FHP, aspects of mandibular movement and TMJ sound were investigated from each posture. Aspects of mandibular movement and TMJ sound were observed by measuring total vibration energy(Integral), peak amplitude, maximum amound of mouth opening, and TMJ sound-emitting point using Sonopak for windows (version 1.33) and Bio-EGN(Bioresearch Inc. WI. U.S.A.). Head and neck movement-measuring instrument, CROM(perfomance attainment Inc. U.S.A.) was to maintain even head posture. Degrees of inclination of UHP and DHP were determined at 30' and distance of FHP was 4cm. The results obtained were as follows. 1. Total vibration energy and peak amplitude of TMJ sounds were decreased more on UHP and on UHP and increased more on DHP and FHP than that on NHP. 2. At the maximum mouth opening, distance of TMJ sound-emitting point were decreased more on UHP and increased more on DHP and FHP than that on NHP. 3. The amounts of the maximum mouth opening were increased more on UHP and decreased more on DHP and FHP than that on NHP. 4. For the changes of the head posture with mouth opening observed in radiograph, condylar head was positioned more lower-anteriorly on UHP, and more upper-posteriorly on DHP and FHP than that on NHP. From the results obtained as above, considering positive influence of the change of head and neck posture, avoiding down-head and forward-head posture, and recommending upper- head posture can prevent the progress of temporomandibular disorder and lead to successful treatment for the patients with temporomandibular joint sounds.

  • PDF