• Title/Summary/Keyword: Distal femoral fracture

Search Result 20, Processing Time 0.023 seconds

A Hip 14 Years after a Non-surgiclly-treated Pipkin Type-II Fracture of the Femoral Head - A Case Report - (핍킨 2형 대퇴골두골절의 보존적 치료 14년 후 결과 - 증례보고 -)

  • Lee, Young-Kyun;Ha, Yong-Chan;Koo, Kyung-Hoi
    • Journal of Trauma and Injury
    • /
    • v.25 no.1
    • /
    • pp.25-27
    • /
    • 2012
  • A 30-year-old, male truck driver had a traffic accident and visited a hospital due to left hip pain. The patient's femoral head was fractured, and he was treated conservatively. For 14 years afterwards, he walked without a limp, had no pain, and drove his truck. He was involved in another traffic accident and experienced a comminuted fracture of the left distal femur 14 years after the initial injury. Although he was symptom-free, while being treated by open reduction and internal fixation for the distal femur fracture, he was concerned about the status of his left femoral head. Pelvis radiographs and reconstructed CT images were done, and they showed a spur change around the femoral head which had a dense sclerotic band within and revealed a slight depression of subchondral bone of the medial portion of the femoral head. The diagnosis was a Pipkin type-II fracture of the femoral head.

Surgical Treatment of Ipsilateral Multi-Level Femoral Fracture Treated Using Antegrade Intramedullary Nail

  • Kim, Beom-Soo;Cho, Jae-Woo;Yeo, Do-Hyun;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2018
  • Ipsilateral fractures of proximal femur with shaft and condylar region are very rare. Current concept of management is based on fixation of each fracture as independent entity using separate fixation modalities for proximal and distal parts of femur. However, we considered that antegrade femoral nailing with cephalomedullary screw fixation is a good option for ipsilateral multi-level femoral fractures. Here, we present an experience of satisfactory treatment for ipsilateral femoral neck fracture, subtrochanteric fracture, comminuted shaft fracture with supracondylar fracture following road traffic accident.

Stress Analysis of Plate Augumentation for Distal Femur Fracture (대퇴부 원위부 골절에 관한 금속판 보강술의 응력 해석)

  • 김지숙;범현규;양영수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.816-819
    • /
    • 1997
  • The operation of femoral non-union after IM(Intramedullary) nailing in distally femoral fractures is considered. Augmentive plate fixation is the management of femoral non-union after IM nailing. The purpose of this study is to compare the bending, torsional stiffness and stress distribution of the two operations by the FEM(Finite Element Method). Augmentive plate fixation is better than IM nail fixation. These results conclude that plate augmentation is a useful method for the unstable femoral non-union after interlocking IM nailing.

  • PDF

Pseudoaneurysm Originating from the Lateral Femoral Circumflex Artery after Retrograde Intramedullary Nailing of a Distal Femur Shaft Fracture (원위 대퇴골 골절에서 역행성 골수 정 시행 후 발생한 외측 대퇴 회선 동맥 기원의 가성동맥류)

  • Yu, Jeongseok;Lee, Beom-Seok;Kim, Han-Bit
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.535-539
    • /
    • 2021
  • Vascular complications following a femoral fracture are rare but can result in serious issues. Several case studies have reported pseudoaneurysms occurring after direct trauma or the insertion of a proximal femoral nail in the case of a proximal femoral fracture. The authors encountered an 85-year-old patient treated with retrograde intramedullary nail fixation for a distal femur fracture and suffered a decrease in the hemoglobin level, swelling, and pain on the 9th day after surgery. The authors initially attributed the temporary hematoma and pain to ordinary postoperative processes. On the 16th day after surgery, a pseudoaneurysm originating from the descending branch of the lateral femoral convolutional artery was diagnosed and treated by percutaneous vascular embolization. After the procedure, the hemoglobin level increased, and the swelling and pain decreased.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF

Clinical and Radiological Outcome of Distal Femoral Fracture in Elderly Patient Group (원위 대퇴골 골절에 대한 고령 환자군의 치료 결과 비교 -임상적, 방사선학적 비교-)

  • Park, Hee-Gon;Kim, Yeon-Jun;Jang, Ho-Seong
    • Journal of Trauma and Injury
    • /
    • v.26 no.4
    • /
    • pp.286-290
    • /
    • 2013
  • Purpose: To report the postoperative Clinical and Radiological outcomes following distal femoral fractures in elderly patients compared with young patients. Methods: From March, 1996 to March, 2012, 83 patients who received surgical treatment for fractures of the distal femur were enrolled in this retrospective study. Ages more than 65 was named group A. Group A was 49 cases and mean age is 72.5 year(65~91year). Group B was 49 cases and mean age is 45.7 year(16~61 year). Surgical methods are retrograde IM nail, locking compression plate, cannulated screw and postoperative rehabilitation is no difference between two groups. Clinical results were evaluated using Neer scores, radiographic results and the presence of clinical complications. Results: The mean union period was 18.4(12-40) weeks in group A and 17(10-24) weeks in group B. Neer functional scores are no significant statistical difference between two groups. There are 5 cases metal breakage in group A and 1case in group B. There are 3 cases nonunion in group A and 1 case in group B. Conclusion: In the case of fractures of the distal femur in elderly patients, locking plate using minimally invasive percutaneous periosteal osteosynthesis (MIPPO) technique may be one of the most effective methods and preoperative bone stock evaluation in important.

Effects of Electrical Stimulation on Femoral Fracture Healing in a Dog Model (전기자극이 개의 대퇴골절 치유에 미치는 영향)

  • 박경철;이주명;윤영민;강태영;김희석;이경갑;강윤호;정종태
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.328-333
    • /
    • 2003
  • This study was performed to investigate the effects of electrical stimulation on femoral fracture healing in dogs. Eight healthy dogs from 4 to 5 $\beta^3$ were used in this experiment. In the treatment group, anode and cathode were connected to proximal and distal site apart from the fracture line by 2 cm and electrical stimulation was applied to the fracture site for l5minutes by 2 V, 25 Hz and for a month. The control group was connected to electrostimulator as the treatment group, but no electrical stimulation was applied. Various parameters were evaluated including radiograph and serum levels of total-ALP(TALP), bone-ALP(BALP) and osteocalcin. The radiography revealed more rapid callus formation in the treatment group than in the control by about a week. The total-ALP levels of the treatment group were higher than those of the control group from the 2nd to the 24th day(p< 0.05). The bone-ALP levels of the treatment group were significantly higher than those of the control from the 2nd to the 24th day(p< 0.05). The bone-ALP/ total-ALP ratios of the treatment group were higher than those of control throughout this experiment but there were no significance. There were no significance in the osteocalcin levels between two groups. In conclusion, the electrical stimulation on femoral fracture site was effective for bone healing in dogs.

The Stress Concentration Caused by Pin-hole in Femur after Computer-navigated Total Knee Arthroplasty: A Finite Element Analysis (컴퓨터 네비게이션을 이용한 슬관절 전치환술에서 핀 홀에 의한 응력 집중: 유한요소해석)

  • Park, Hyung-Kyun;Kim, Yoon-Hyuk;Park, Won-Man;Kim, Kyung-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.451-456
    • /
    • 2008
  • Total knee arthroplasty(TKA) using computer-assisted navigation has been increased in order to improve the accuracy of femoral and tibial components implantation. Recently, a few clinical studies have reported on the femoral stress fracture after TKA using computer-assisted navigation. The purpose of this study is to investigate the stress concentration around the femoral pin-hole for different pin-hole diameter, the modes of pin penetration by finite element analysis to understand the effects of pin-hole parameters on femoral stress fracture risk. A three-dimensional finite element model of a male femur was reconstructed from 1 mm thick computed tomography(CT) images. The bone was rigidly fixed to a 25 mm above the distal end and 1500 N of axial compressive force and 12 Nm of axial torsion were applied at the femoral head. For all cases, transcortical pin penetration mode showed the highest stress fracture risk and unicortical pin penetration mode showed the lowest stress concentration. Pin-hole diameter increased the stress concentration, but pin number did not increase the stress dramatically. The results of this study provided a biomechanical guideline for pin-hole fracture risk of the computer navigated TKA.

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

Delayed Post-traumatic Coarctation of Distal Abdominal Aorta - A Case Report - (수직추락후 발생한 복부대동맥 협착 1례 보)

  • Park, Guk-Yang;Lee, Hong-Seop;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.199-201
    • /
    • 1987
  • We have recently experienced a rare case of abdominal aortic injury caused by deceleration force during fall in upright position. The patient was 43-year-old brick-layer fell from 12 meter height and sustained compression fracture of the spine and both legs. The aortic injury was unnoticed at that time. About 2 years later, marked stenosis of the distal abdominal aorta was found together with clinical manifestations of ischemia of both legs. Aorto-femoral bypass on both sides has completely relieved the symptoms, Similar type of abdominal aortic injuries could not be found in the literatures.

  • PDF