• Title/Summary/Keyword: Distal attachment

Search Result 52, Processing Time 0.025 seconds

A Photoelastic Stress Analysis of Bilateral Distal Extension Removable Partial Denture with Attachment Retainers (정밀 부착형 유지장치에 따른 양측성 유리단 국소의치의 광탄성 응력분석)

  • Cho, Hye-Won;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.97-112
    • /
    • 1985
  • The purpose of this study was to evaluate the stress patterns developed in supporting structures by removable partial denture with attachment retainers. The attachments tested were Dalbo(miniature) attachment, resilient Ceka attachment, rigid Ceka attachment, precision and sleeve attachment, and R.P.I. clasp as a contrast. 3-dimensional photoelastic stress analysis was used to record the isochromatic and isoclinic fringe patterns and to calculate principal stress components at measuring points. The results showed that: 1. The maximum compressive stress on residual ridge was produced under the loading point with Dalbo and resilient Ceka attachment, distal to the loading point with rigid Ceka and precision and sleeve attachment, and mesial to the loading point with R.P.I. clasp. 2. The Dalbo attachment produced the most stress on residual ridge, and the least stress on abutment teeth. and resilient Ceka attachment showed favorable stress distribution. 3. Rigid Ceka attachment produced higher compressive stress on buccal. alveolar crest, and precision and sleeve attachment produced higher compressive stress on distal alvelolar crest and mesial surface of the root apex in abutment teeth. 4. R.P.I. clasp produced higher compressive stress on mesial alveolar crest.

  • PDF

A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE FORCE DISTRIBUTION BY DISTAL EXTENSION PARTIAL DENTURES EMPLOYING ATTACHMENTS (Attachment를 이용한 후방연장 국소의치에 의한 압력분산에 관한 3차원 유한요소분석)

  • Shin, Sang-Wan;Ahn, Won-Jun;Jung, Yeon-Jin;Lee, Young-Soo;Shim, Kwang-Sup;Yoo, Kwang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.878-887
    • /
    • 1998
  • Although attachments have been utilized for a retainer of removable prostheses during several decades, there is little information on the force distribution by the attachments. This study was undertaken to evaluate the stress patterns developed by partial dentures employing rigid attachments on the supporting structures. Four types of the mandibular removable partial dentures were designed depending upon the position of the rigid attachment and the existency of lingual bracing. Under 100N of vertical and 25N of lateral loads on the 1st and 2nd lower molar of partial denture, stress distribution patterns and displacement were analysed with three dimensional finite element method by ANSYS version 5.3. 1. The highest stresses were concentrated on the distal alveolar crest of posterior abutment and the second stresses on the apical region of posterior abutment in the models. 2. The greatest displacement were shown on the distal alveolar crest of posterior abutment and the second displacement on the distal alveolar crest of anterior abutment in the models. 3. There was little difference between the models with intraoral attachment and those with extracoronal attachment. 4. There was little difference between the models with and without the lingual bracing.

  • PDF

THE THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PARTIALLY EDENTULOUS IMPLANT PROSTHESIS WITH VARYING TYPES OF NON-RIGID CONNECTION (부분 무치악 임플랜트 보철 수복시 자연치와의 비고정성 연결형태에 따른 3차원 유한요소법적 연구)

  • Lee, Seon-A;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.101-124
    • /
    • 1996
  • In this study, we designed the finite element models of mandible with varying their connecting types between the prosthesis on implant fixture and 2nd premolar, which were free-standing case(Mf), precision attachment case(Mp), semiprecision attachment case(Ms) and telescopic case(Mt). The basic model of the designed finite element models, which contained a canine and the 1st & 2nd premolar, was implanted in the edentulous site of the 1st & 2nd molar by two implant fixtures. We applied the load in all models by two ways. A vertical load of 200N was applied at each central fossa of 2nd premolar and 1st implant. A tilting load of 20N with inclination of $45^{\circ}$ to lingual side was applied to buccal cusp tips of each 2nd premolar and 1st implant. And then we analyzed three-dimensional finite element models, making a comparative study of principal stress and displacement in four cases respectively. Three-dimensional finite element analysis was performed for the stress distribution and the displacement using commercial software(IDEAS program) for SUN-SPARC workstation. The results were as follows : 1 Under vertical load or tilting load, maximum displacement appeared at the 2nd premolar. Semiprecision case showed the largest maximum displacement, and maximum displacement reduced in the order of precision attachment, free-standing and telescopic case. 2. Under vertical load. the pattern of displacement of the 1st implant appeared mesio-inclined because of the 2nd implant splinted together. But displacement pattern of the 2nd premolar varied according to their connection type with prosthesis. The 2nd premolar showed a little mesio-inclined vertical displacement in case of free-standing and disto-inclined vertical displacement due to attachment in case of precision and semiprecision attachment. In telescopic case, the largest mesio-inclined vertical displacement has been shown, so, the 1st premolar leaned mesial side. 3. Under tilting load, The pattern of displacement was similar in all four cases which appeared displaced to lingual side. But, the maximum displacement of 2nd premolar appeared larger than that of the first implant. Therefore, there was large discrepancy in displacement between natural tooth and implant during tilting load. 4. Under vertical load, the maximum compressive stress appeared at the 1st implant's neck. Semiprecision attachment case showed the largest maximum compressive stress, and the maximum compressive stress reduced in the order of precision attachment, telescopic and free-standing case. 5 Under vertical load, the maximum tensile stress appeared at the 2nd implant's distal neck. Semiprecision attachment case showed the largest maximum tensile stress, and the maximum tensile stress reduced in the order of precision attachment, telescopic and free-standing case. 6. Under vertical load or tilting load, principal stress appeared little between natural tooth & implant in free-standing case, but large principal stress was distributed at upper crown and distal contact site of the 2nd premolar in telescopic case. Principal stress appeared large at keyway & around keyway of distal contact site of the 2nd premolar in precision and semiprecision attachment case, appearing more broad and homogeneous in precision attachment case than in semiprecision attachment case.

  • PDF

A THREE DIMEMSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTING BONE TISSUE ACCORDING TO DESIGN OF ATTACHMENTS USED FOR MANDIBULAR OVERDENTURE USING TWO OSSEOINTEGRATED IMPLANSTS (두개의 골유착성 임프란트를 이용한 하악 OVERDENTURE에서 ATTACHMENT 설계에 따른 임프란트 지지조직의 삼차원적 광탄성 응력분석)

  • Shin, Kyoo-Hag;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.31-69
    • /
    • 1996
  • The purpose of this investigation was to analyze stress distribution in implant supporting tissue according to different types of attachments such as combination bar attachment, Hader bar attachment, O-Ring attachment and Dal-Ro attachment that are used in mandibular overdenture by using two osseointegrated implants, to study the influence that POM IMC used in bar type attachment has in implant supporting tissue and compare the preceding analyses to find out an effective stress distribution method. Three dimensional photoelastic method was used to obtain the following results. (A) Analysis of stress distribution according to attachment type 1. Under vertical load condition, compressive stress was seen at implant supporting area of working side on all the photoelastic models but in Hader bar attachment tensional stress was seen at distal upper area of implant supporting area. Relatively Hader bar and O-Ring attachment showed even stress distribution pattern. 2. Under vertical load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models. 3. Under $25^{\circ}$ lateral load condition, general compressive stress was seen at working side implant supporting area in most of the models, especially at distal upper supporting area higher compressive stress concentration was seen in combination bar attachment and tensional stress concentration, in Hader bar attachment. 4. Under $25^{\circ}$ lateral load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models, except O-Ring model which showed compressive stress only. (B) Influence of POM IMC to stress distribution in bar type attachment 5. Under vertical load condition, better stress distribution pattern was seen at working side of combination bar and Hader bar attachment model using POM IMC. 6. Under vertical load condition, stress value was increased at nonworking side of combination bar attachment model using POM IMC and tendency of increasing compression was seen at nonworking side of Hader bar attachment model using POM IMC. 7. Under $25^{\circ}$ lateral load condition, better stress distribution pattern was seen at working side of combination bar attachment model using POM IMC but tendency of increasing stress was seen on working side of Hader bar attachment model using POM IMC. 8. Under $25^{\circ}$ lateral load condition, stress reduction was seen at nonworking side of combination bar attachment model using POM IMC but tendency of increasing stress was seen at nonworking side of Hader bar attachment model using POM IMC.

  • PDF

Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

  • Kim, Min-Jeong;Hong, Sung-Ok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.85-93
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS. Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional finite element analysis. RESULTS. In all experimental models, the highest stress was concentrated on the most distal implant and implant supporting bone on loaded side. The stress at the most distal implant-supporting bone was concentrated on the cortical bone. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant and implant supporting bone on loaded side. CONCLUSION. It could be suggested that when making maxillary implant retained overdenture, using Hader bar instead of milled bar and full palatal coverage rather than partial palatal coverage are more beneficial in distributing the stress that is applied on implant supporting bone.

THE EFFECTS OF TOOTH MOBILITY AND DESIGN OF DIRECT RETAINER ON THE STRESS OF SUPPORTING TISSUES IN UNILATERAL DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (편측후방연장 국소의치에서 지대치 동요도와 직접유지장치의 설계가 지지조직의 응력에 미치는 영향)

  • Jong, Young-Wan;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.59-72
    • /
    • 2000
  • This study was performed to investigate the effects of tooth mobility and design of the direct retainer on the stress of supporting tissues in distal extension removable partial denture. Tooth mobility was simulated and four different types of direct retainer such as Alters clasp, I-bar clasp, wrought wire clasp, and Dalbo attachment were designed and stress on the support-ing tissues were measured and analyzed with straingauge method. The following conclusions were drawn from this study. 1. The stress revealed at the lingual side of alveolar bone of the abutment tooth in edentulous area was the largest. 2. The stress at the lingual side of alveolar bone of the abutment tooth in edentulous area was increased according to the increase of tooth mobility in I-bar clasp and Dalbo attachment. 3. The stress at the residual ridge crest was the great in Dalbo attachment on mobility 0, in I-bar clasp on mobility 1, and in wrought wire clasp on mobility 2. 4. There was little changes of stress according to the increase of tooth mobility at buccal and lingual side of the residual ridge crest and around the abutment teeth in dentulous area.

  • PDF

A PHOTOELASTIC STUDY ON THE STRESS ANALYSIS UNDER MADIBULAR DISTAL-EXTENSION REMOVABLE PARTIAL DENTURE WITH DIFFERENT DESIGN OF THE MAJOR CONNECTOR (주 연결장치의 설계변화에 따른 하악 유리단 국소의치의 광탄성 응력 분석에 관한 연구)

  • Lee, Kyw-Chil;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.177-194
    • /
    • 1991
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a distal extension removable partial dentures with three kinds of mandibular major connectors, that is, lingual bar, linguoplate, and swing-lock attachment. A photoelastic model was made of the epoxy resin(PC-1) and hardener(PCH-1) and coated with plastic cement-1 (PC-1) at the lingual surface of the epoxy model and set with three kinds of chrome-cobalt removable partial dentures. A bilateral vertical load of 15kg to the middle portion of the metal bar crossing both the first molars of the right and the left, and a unilateral vertical load of 12.5kg to the right first molar were applied with the use of specially designed loading device and the reflective circular polariscope was used to analyze the photoelastic model under each condition. The following results were obtained : 1. When the bilateral vertical load was applied, the magnitude and distribution of the stress concentration of the edentulous area and the terminal abutment or adjacent teeth was in the order of lingual bar, linguoplate, swing-lock attachment. 2. When the unilateral vertical load was applied, the magnitude and distribution of the stress concentration of the edentulous area and the terminal abutment or adjacent teeth was in the order of lingual bar, linguoplate, swing-lock attachment. 3. When the unilateral vertical load was applied, the magnitude and distribution of the stress concentration of the termial abutment or adjacent teeth on the non-loaded side showed the least stress distribution in case of swing-lock attachment. 4. When the bilateral vertical load and the unilateral vertical load were applied the swing-lock attachment showed the mildest uniform stress distribution on the edentulous area and the alveolar bone around the abutment teeth.

  • PDF

Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application (유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교)

  • Jun, In-Sik;Kim, Bu-Sub;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF