• Title/Summary/Keyword: Dissolved gas analysis

Search Result 115, Processing Time 0.023 seconds

A Fault Diagnostic Expert System for Silicone Oil-filled Transformer Using Dissolved Gas Analysis (유중가스분석법을 이용한 실리콘 유입변압기 고장진단 전문가 시스템)

  • Moon, Jong-Fil;Kim, Jae-Chul;Choi, Joon-Ho;Jun, Young-Jae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.374-376
    • /
    • 2001
  • In this paper, we developed the fault diagnostic expert system of silicone-immersed transformer using dissolved gas analysis. The knowledge base module consists of the knowledge using the rule: if Then . The inference engine uses the fuzzy rule for the management of uncertainty of the boundary and rule and derivate the Belief and Plausibility of the normality and fault using Dempster-Shafer theory. The expert system is connected to the database and it can manages the history of gas-data of the transformer.

  • PDF

Development of Management Software for Transformers Based on Artificial Intelligent Analysis Technology of Dissolved Gases in Oil (지능형 유중가스 분석기술 기반 유입식 변압기 전산관리 프로그램 개발)

  • Sun Jong-Ho;Han Sang-Bo;Kang Dong-Sik;Kim Kwang-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.578-584
    • /
    • 2005
  • This paper describes development of management software for transformers based on artificial intelligent analysis technology of dissolved gases in oil. Fault interpretation using the artificial intelligent analysis is performed by the artificial neural network and a rule based on the analysis of dissolved gases. The used gases are acetylene($C_{2}H_{2}$), hydrogen($H_2$), ethylene($C_{2}H_{4}$), methane($CH_4$), ethane($C_{2}H_{6}$), carbon monoxide(CO) and carbon dioxide($CO_2$). This software is mainly composed of gases input, fault's causes, expected fault's phenomena in detail, the decision on maintenance as well as report and gas trend windows. It is indicated that this is very powerful software for the efficient management of oil-immersed transformers using data analysis of gas components.

The Thermal Aging Characteristics of Cellulose Paper using Analysis for CO, $CO_2$ Gas and Furan Compounds (CO, $CO_2$ 가스와 Furan 함유량의 분석을 통한 셀룰로오스 절연지의 열 열화특성)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.499-504
    • /
    • 2009
  • The analysis for furan compound has provided a complementary technique to dissolved gas analysis(DGA) for monitoring transformers when total concentration of CO and $CO_2$ dissolved in oil only has been evaluated the aging of insulating paper. But, the analysis of furanic compounds by high performance liquid chromatography(HPLC) has been important more than DGA recently. Because it has been known that furanic components in transformer oil have come only from the decomposition of insulating paper. Therefore we have manufactured accelerating aging cell which was aged during 60 hours at 100, 150, 180 and $200^{\circ}C$, respectively, for investigating the characteristics of cellulose paper by thermal using analysis for CO, $CO_2$ and furan compound.

Characterisrics of Dissolved Gas Distribution in Oil with Thermal and Electrical Degradation in Oil Imersed Paper Insulation (유침 절연에서 전기적 및 열적 열화에 따른 유중가스분포특성)

  • Sun, Jong-Ho;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.136-144
    • /
    • 2004
  • Dissolved gas in oil analysis has been used for fault diagnosis of oil immersed insulation. In this paper to improve the reliability in deciding the degradation causes of the oil immersed insulation, we carried out electrical and thermal degradations for the insulations, and analyzed the characteristics of dissolved gases distribution on each situation. As a result more reliable faults discrimination is possible if we use the interrelation of factors like key gases and gas compositions of hydrocarbon gases and ratios of CO/$CO_2$.

Transformation of dissolved organic matter in a constructed wetland: A molecular-level composition analysis using pyrolysis-gas chromatography mass spectrometry

  • Park, Jongkwan;Choi, Mijin;Cho, Jaeweon;Chon, Kyongmi
    • Environmental Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.390-396
    • /
    • 2018
  • This study investigated the transformation of dissolved organic matter (DOM) in a free-water surface flow constructed wetland. Pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) coupled with preparative high-performance liquid chromatography (prep-HPLC) was used to analyze the compositions of biopolymers (polysaccharides, amino sugars, proteins, polyhydroxy aromatics, lipids and lignin) in DOM according to the molecular size at three sampling points of the water flow: inflow, midflow, and outflow. The prep-HPLC results verified the decomposition of DOM through the decrease in the number of peaks from three to one in the chromatograms of the sampling points. The Py-GC/MS results for the degradable peaks indicated that biopolymers relating to polysaccharides and proteins gradually biodegraded with the water flow. On the other hand, the recalcitrant organic fraction (the remaining peak) in the outflow showed a relatively high concentration of aromatic compounds. Therefore, the ecological processes in the constructed wetland caused DOM to become more aromatic and homogeneous. This indicated that the constructed wetland can be an effective buffer area for releasing biochemically stable DOM, which has less influence on biological water quality indicators, e.g., biochemical oxygen demand, into an aquatic ecosystem.

Studies on Simultaneous Analysis of Organophosphorus Pesticide Residues in Crops by Gas-Liquid Chromatography (I) Extraction and Cleanup (기체-액체 크로마토그래피에 의한 농작물 중 유기인제 잔류 농약의 동시 분석에 관한 연구 (제 1 보). 용매추출 및 방해성분의 분리 제거)

  • Taek-Jae Kim;Yun-Woo Eo;Young Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.465-474
    • /
    • 1986
  • The solvent extraction and cleanup processes for the simultaneous gas-liquid chromatographic determination of 11 kinds of organophosphorous pesticide residues in crops were investigated. The extracts dissolved with acetone were partitioned with petroleum ether after adding saturated NaCl solution. Evaporated the partitioning solvent, the residue was dissolved in methylene chloride and eluted through mixed adsorbent (1 : 2 : 4 of activated carbon, magnesia and diatomaceous earth) with methylene chloride as an eluent. The pesticides recovered were 82∼105% and the impurities were effectively removed.

  • PDF

Analysis of Furanic Compounds Dissolved in Transformer Oil (변압기에 용존된 Furan계 물질 분석)

  • Kim, Jae-Hoon;Lee, Byung-Sung;Lee, Sei-Hyun;Koo, Kyung-Wan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1909-1911
    • /
    • 2005
  • The electrical and chemical characteristics in transformer insulations are changed due to thermal stress. In the chemical property, as the Kraft paper ages, the cellulose polymer chains breakdown into shorter lengths with a corresponding decrease in both tensile strength and degree of polymerization(DP). Furthermore, cellulous chains breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furan products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. In this paper the accelerated aging process of oil--paper samples have been investigated at a temperature up to $140^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. For analysis we used high performance liquid chromatography(HPLC) in accordance with IEC 61198 method.

  • PDF

A Hybrid Type Based Expert System for Fault Diagnosis in Transformers (변압기 고장 진단을 위한 하이브리드형 전문가 시스템)

  • Jeon, Young-Jae;Yoon, Yong-Han;Kim, Jae-Chul;Choi, Do-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.143-145
    • /
    • 1996
  • This paper presents the hybrid type based expert system for fault diagnosis in transformers. The proposed system uses the novel fault diagnostic technique based on dissolved gas analysis(DGA) in oil-immersed transformers. The uncertainty of key gas analysis, norm threshold, and gas ratio boundaries are managed by using a fuzzy set. Also, the uncertainty of the fault diagnostic rules are handled by using fuzzy measures. Finally, kohnen's feature map performs fault classification in transformers. To verify the effectiveness of the proposed diagnosis technique, the hybrid type based expert system for fault diagnosis has been tested by using KEPCO's transformer gas records.

  • PDF

Novel Apparatus for Seawater Desalination and Its Application (신개념 해수담수 플랜트 적용을 위한 장치개발 및 적용기술)

  • Lee, Ju Dong;Kang, Kyung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.407-412
    • /
    • 2014
  • A new apparatus for seawater desalination, based on the principle of gas hydrates, is suggested. The equipment continuously produces and pelletizes gas hydrates by a squeezing operation in a dual cylinder unit, which is able to extract pure hydrate pellets from the seawater-containing reactor. Desalination efficiency for each dissolved ion from seawater samples was tested by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and ion chromatography (IC) analysis. This study demonstrates that the suggested method and the stated apparatus may solve the difficulty of separating hydrate crystals from concentrated brine solutions, and therefore may be applied to improve the efficiency of existing desalination processes.

A study on Cause of Errors of Dissolved Gases Analysis in Transformer (변압기 유중 가스 진단 오차 원인에 대한 연구)

  • Cho, Sung-Min;Lee, Yang-Jin;Kim, Young-Sung;Kim, Jae-Chul;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.141-143
    • /
    • 2006
  • Dissolved gas analysis (DGA) is widely used to detect incipient faults in oil-filled electrical equipment. KEPCO make a rule of DGA in 1985. They have been diagnosing power transformer using their DGA criteria. In this paper, we analysis the result of DGA data about transformer in the substation. We try to find out what is cause of an error in DGA diagnosis considering accuracy in extracting gases from mineral oil in transformer. The carbon-monoxide was primary reason of warning in DGA data. We specially consider that aging is a cause of generating of carbon-monoxide in power transformer.

  • PDF