• Title/Summary/Keyword: Dissolved air flotation (DAF)

Search Result 80, Processing Time 0.022 seconds

Effect of Application of Streamline and Mobility Function on Bubble-Floc Collision Efficiency for Trajectory Analysis of DAF Process (DAF공정의 궤적분석에서 유선과 운동함수의 적용이 기포와 플록의 충돌효율에 미치는 영향)

  • Kim, Seong-Jin;Kwak, Dong-Heui;Lim, Young-Hwan
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.676-684
    • /
    • 2004
  • Many researchers have been carrying on study to figure out the exact collision efficiency between bubble and floc. Collision efficiency can has generally been quantified by using trajectory analysis which uses the hydrodynamic, the electrostatic and van der waals forces. Two types of method are considered to induce the hydrodynamic force in the trajectory analysis. One is to use stream function and the other is to use mobility function. There was some difference between stream and mobility function depending upon modelling factors and conditions in trajectory analysis.

Evaluation of Flotation Efficiency and Particle Separation Characteristics of Carbon Dioxide Bubbles using Collision Efficiency Model (단일포집자충돌(SCC) 모델을 이용한 이산화탄소기포의 입자분리특성과 부상효율 평가)

  • Lee, Jun-Young;Kim, Seong-Jin;Yoo, Young-Hoon;Chung, Paul-Gene;Kwon, Young-Ho;Park, Yang-Kyun;Kwak, Dong-Heui
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.129-136
    • /
    • 2012
  • In this century, scientists realized that carbon dioxide gas in the atmosphere cause a greenhouse effect which affects the planet's temperature. Therefore lots of attempts have carried out to decrease the discharge of carbon dioxide gas in the field. The dissolved carbon dioxide flotation (DCF) process was developed as an alternative of DAF process to decrease the discharge and reuse of carbon dioxide as well as to save energy consumption. To investigate the particle separation characteristics and the flotation efficiency of carbon dioxide, SCC model was employed in the DCF process which has been applied extensively for the evaluation and simulation in the DAF process. The simulation results by the SCC model revealed the predicted curve of flotation efficiency became decreased gradually over the optimal pressure range of saturator about 1.6 atm in accordance with the experiment results of the DCF pilot plant and the size distribution and the bubble volume concentration of $CO_{2}$ bubbles depending on the operation pressure of saturator. The findings through the simulation results led to the conclusion that there was no significant difference between $CO_{2}$ bubbles and air bubbles, affecting on the practical flotation efficiency, in terms of the initial collision and attachment efficiency.

Performance Evaluation of Ball Media Filter in DABF applied to SWRO pretreatment process (SWRO 전처리 공정에 적용된 DABF 내 Ball Media Filter 성능 평가)

  • Choi, Seokho;Lee, Junghyun;Park, Sungju;Lee, Younggeun;Roh, Hyungkeun;Kim, Yongbeom
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.567-573
    • /
    • 2019
  • DABF(Dissolve Air Flotation with Ball Filter) is developed as the DAF with the addition of a fiber ball at the lower part of the DAF. The DABF with a capacity of 4,500 ㎥/h was constructed at Gijang SWRO plant in Busan. Since the ball filter has high filtration rate, the loading rate of DABF was designed from 20 to 42 ㎥/h/㎡. When one DABF basin is in the back washing mode, the loading rate of other two DABF basins is increased to 42 ㎥/h/㎡. Turbidity at the BF outlet in DABF is <2 NTU at turbidity of 5-10 NTU at the BF inlet. If there is no algae bloom and turbidity is low in raw seawater, only BF in DABF is operated and meets <2 NTU at the BF outlet. Even if BF is operated at high hydraulic loading rates, no significant differential pressure increases and reduction in the turbidity removal rate is minimal in a day. Thus, DABF is the pre-treatment technology that provides stable water quality even with BF onlyoperation without DAF operation. Compared with the DAF, DABF requires additional facilities such as valves, piping, and drainage systems for backwashing the BF. But in terms of footprint and operating costs, DABF has more advantages than DAF. With DABF application, the load of the downstream filtration equipment is decreased so that the capacity of the filtration equipment can be reduced. Also, if the downstream filtration equipment is to be maintained the same regardless of DABF, the operating cost of DABF is less than DAF.

Measuring Zetapotential of Microbubbles in DAF (용존공기부상법(容存空氣浮上法)(DAF)에서 미세기포(微細氣泡)의 제타전위측정(電位測定))

  • Dock Ko, Seok;Han, Moo Young;Park, Chung Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.53-58
    • /
    • 1998
  • Dissolved Air flotation (DAF) has become increasingly important in the field of drinking water treatment, however, the research to investigate the mechanism of collision between bubble and particle has been limited. The electrostatic repulsion forces between them are critical to collide with each other. Zetapotential of bubble and particle show their electrostatic condition. In this research, a setup to measure the zetapotential of rising microbubble is made using electrophoresis method and measured ZP of bubble in our Lab. The results show the effect of pH on zetapotential of bubble. The findings from this research are compared with other results. It will he helpful to understand and explain the mechanism of collisions between bubble and particle on different conditions of bubble charge in DAF process.

  • PDF

Release of Oxygen from a Nano-sized Water Droplet Observed using Molecular Dynamics

  • Lee, Chang-Han;Ambrosia, Matthew Stanley
    • Journal of Environmental Science International
    • /
    • v.25 no.7
    • /
    • pp.927-935
    • /
    • 2016
  • Dissolved oxygen is necessary for many biological processes as well as many industrial practices. Dissolved oxygen released from water in dissolved air flotation (DAF) systems can be have many different applications. However, DAF systems are very costly to operate. To develop more efficient DAF systems, a deeper understanding of the process of oxygen being released from water is required. In this study, molecular dynamics (MD) simulations were used to simulate 100 oxygen molecules surrounded by 31002 water molecules at temperatures ranging from $0^{\circ}C$ to $100^{\circ}C$. Simulations were carried out for 10 ns, during which, in most cases, all the oxygen molecules were released from the water droplet. With MD simulations, visualization of the molecules escaping the water droplet was possible, which aided the understanding of the interactions between molecules at the nano-scale. The results showed that as the oxygen molecules moved near the edge of the water droplet that the oxygen molecules hesitated before escaping the water droplet or returned to the interior of the water droplet. This was because of the attractive forces between the water and oxygen molecules. Moreover, after most of the oxygen molecules were released from the droplet, some were found to return to the droplet's edge or even the interior of the droplet. It was also confirmed that oxygen molecules were released at a faster rate at higher temperatures.

A Study on the Ozoflotation Process for Drinking Water Treatment (Ozoflotation 공정의 정수처리 적용에 관한 연구)

  • Kang, Tae Hee;Oh, Byung Soo;Lee, Hoon;Byun, Kyu Sik;Kwon, Soon Buhm;Sohn, Byeong Yong;Ahn, Hyo Won;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.528-534
    • /
    • 2005
  • Ozone, a powerful oxidant, is widely used to remove microorganisms, pesticides, taste and odor compounds effectively. Dissolved air flotation (OAF) has been known as an economical process for treating algae and low turbid water quality. An ozoflotation system, combining ozone and OAF processes, has a merit which can operate the ozonation and flotation process simultaneously in a single compartment. This study investigated the application of the ozoflotation process for advanced water treatment by carrying out the pilot-plant experiment. During the test, ozone microbubbles were generated through a OAF pump and many kinds of parameters were evaluated under several conditions, such as raw water flow rate and ozone dose. As a result of the test, the optimum operating conditions of ozoflotation were decided to be 1.2 mg/L ozone dose and about 34 minute Hydraulic retention time (HRT). Finally, it could be demonstrated that the ozoflotation system can effectively improve the drinking water quality.

Effect of Chemical Conditioning on Flotation and Thickening Efficiencies of Sewage Sludge (화학적인 개량이 하수슬러지의 부상농축효율에 미치는 영향)

  • Lee, Chang-Han;Ahn, Kab-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.743-748
    • /
    • 2009
  • Chemical sludge conditioning is widely used to improve the dewatering efficiency. It is treated with commonly used conditioners, and then thickened and dewatered with a mechanical device. This paper aims to examine the flotation and thickening efficiencies of sewage sludge for conditioning conditions, such as unaerobic storage time, kinds of coagulant and dosages, and flotation conditions, such as sludge concentration and A/S ratio, using an dissolved air flotation apparatus. Experimental results showed that the specific surface area and specific resistance to filtration (SRF) were significantly increased and the flotation and thickening efficiencies were decreased with anaerobic storage time. However, the flotation and thickening efficiencies faintly decreased in sewage sludges conditioned as $Al_2(SO_4)_3$, $Fe_2(SO_4)_3$, and PSO-M. Flotation and thickening efficiencies in conditioned sewage sludge could be sustained up to 96% at A/S ratio of 0.01 mL/mg or over.

A Study on Solid-liquid Separation of Swine Wastewater Using Coagulation and Dissolved Air Flotation (응집침전 및 부상분리에 의한 돈사폐수의 고액분리에 관한 연구)

  • Kim, Jong-Oh;Jeong, Seong-Uk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • In this study, the solid-liquid separation characteristics of swine wastewater were investigated for the coagulation and dissolved air flotation (DAF). Coagulation characteristics were studied using jar-tester with the different coagulants and dosage amounts. DAF characteristics were also investigated in terms of the different flotation conditions with the raw swine wastewater, pH adjustment only, and adding coagulants. When the raw swine wastewater was coagulated with the only inorganic coagulants, the proper inorganic coagulants were founded as $FeCl_3$ > PAC > Alum orderly, and the optimal coagulant dosages were founded as $1,000mg/{\ell}$, $1,500mg/{\ell}$, $1,500mg/{\ell}$, respectively. As the raw swine wastewater was treated with the polymer coagulants, the only cationic polymer coagulant showed an effective coagulation and the optimal dosage of cationic coagulant was founded as $200mg/{\ell}$. When the different dosages of cationic polymer was added to each $500mg/{\ell}$ of the inorganic coagulants, the proper inorganic coagulants were founded as $FeCl_3$ > Alum > PAC orderly, and optimal cationic polymer dosages was founded as $25mg/{\ell}$, $25mg/{\ell}$, and $100mg/{\ell}$, respectively. Resulting from the raw swine wastewater experiments using DAF without coagulation, the proper operation conditions of DAF were set to 400% of recycling ratio, 4 atm in air dissolving tank, and under pH 3. But the raw swine wastewater was difficult to successfully operate DAF without pre-coagulation. While the DAF separation after pre-coagulation using inorganic coagulants was not accomplished due to the low intensity of the floc, DAF after pre-coagulation using both the inorganic and cationic polymer coagulants was accomplished very well. Optimal dosage of cationic polymer coagulant in case of $500mg/{\ell}$ Alum dosage was founded as $500mg/{\ell}$.

  • PDF

Sludge Thickening using Electro-Flotation in Water Treatment Plant (전해부상에 의한 상수 슬러지 농축효율)

  • Lee, Jun;Han, Mooyoung;Dockko, Seok;Park, Yonghyo;Kim, Tschungil;Kim, Mikyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Gravity thickening process has been widely used in WTP sludge thickening at domestic water treatment plant. The operation method of the process is very simple, however, the process requires long detention time about 24~48 hours for sludge thickening, uses polymer, and low total solids of thickened sludge to increase sludge thickening efficiency. To solve there problems, we studied about flotation process, especially, electro-flotation (EF) process in WTP sludge thickening. Electro-flotation process is simpler than dissolved-air-flotation(DAF) process because EF needs only electrode and current to generate micro-bubbles and the operation is easy. This study was performed at two batch columns to compare interface height, total solids, effluent turbidity between an electro-flotation thickening and a gravity thickening. According to the result, an electro-flotation thickening was that interface height was decreasing, total solids had high concentration, and effluent turbidity was low in comparison with a gravity thickening. Also, it will make the high efficiency of following process, such as a dehydrating process and digestive process. because of high total solids and low moisture content in the sludge.

A Study on the Separation of Activated Sludge by Dissolved Air Flotation (가압부상법(加壓浮上法)에 의한 활성(活性)슬러지 혼합액(混合液)의 고액분리(固液分離)에 관한 연구(研究))

  • Yang, Sang Hyun;Ra, Deog Gwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.21-29
    • /
    • 1985
  • An effective technique of sludge separation is required for concentrated activated sludge process. The dissolved-air flotation (DAF) has been shown to be efficient process for sludge separation. The factors affecting DAF process for activated sludge separation are type and concentration of sludge, air/solid ratio, ratio of pressurized water flow, pressure, sludge detention time, temperature, sludge and hydraulic loading rate, recycle flow rate of sludge and type and quantity of chemical aid. In order to study the optimal operation condition for sludge separation, the influence factors such as type and concentration of sludge, ratio of pressurized water flow and pressure are investigated by the batch and continuous reactor experiments of DAF and sedimentation test. By the experimental investigation, the results are as follows; 1. For the bulking and concentrated sludge, DAF is more effective than sedimentation for the sludge separation. 2. In DAF, the critical ratio of pressurized water flow exist. The critical value varies with the pressure in the tank. That is, according to the pressure changes from 3 to $5kg/cm^2$, the critical value varies from 0.25 to 0.67 accordingly. 3. Pressure affects the ratio of pressurized water flow, but it does not show any influence upon the DAF efficiency directly. 4. Continuous experimental results was not better than those of batch.

  • PDF