• Title/Summary/Keyword: Displacement Calibration

Search Result 120, Processing Time 0.028 seconds

Evaluation of Robot Calibration Performance based on a Three Dimensional Small Displacement Measuring Sensor (3차원 미소변위센서 기반 로봇 캘리브레이션 성능 검토)

  • Nguyen, Hoai-Nhan;Kang, Hee-Jun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.12
    • /
    • pp.1267-1271
    • /
    • 2014
  • There have been many autonomous robot calibration methods which form closed loop structures through the various attached sensors and mechanical fixtures. Single point calibration among them has been used for on-site calibration due to its convenience of implementation. The robot can reach a single point with infinitely many configurations so that single point calibration algorithm can be set up and easily implemented relative to the other methods. However, it is not still easy to drive the robots' sharp edge to its corresponding edge of the fixture. This is error-prone process. In this paper, we propose a 3 dimensional small displacement measuring sensor and a robot calibration algorithm based on this sensor. This method relieves the difficulty of matching two edges in the single point calibration and improves the resulting robot accuracy. Simulated study is carried out on a Hyundai HA06 robot to show the effectiveness of the proposed method over the single point calibration. And also, the resulting robot accuracy is compared with that from 3D laser tracker based calibration to show the dependency of robot accuracy on range of the workspace where the measurement data are collected.

Laser pose calibration of ViSP for precise 6-DOF structural displacement monitoring

  • Shin, Jae-Uk;Jeon, Haemin;Choi, Suyoung;Kim, Youngjae;Myung, Hyun
    • Smart Structures and Systems
    • /
    • v.18 no.4
    • /
    • pp.801-818
    • /
    • 2016
  • To estimate structural displacement, a visually servoed paired structured light system (ViSP) was proposed in previous studies. The ViSP is composed of two sides facing each other, each with one or two laser pointers, a 2-DOF manipulator, a camera, and a screen. By calculating the positions of the laser beams projected onto the screens and rotation angles of the manipulators, relative 6-DOF displacement between two sides can be estimated. Although the performance of the system has been verified through various simulations and experimental tests, it has a limitation that the accuracy of the displacement measurement depends on the alignment of the laser pointers. In deriving the kinematic equation of the ViSP, the laser pointers were assumed to be installed perfectly normal to the same side screen. In reality, however, this is very difficult to achieve due to installation errors. In other words, the pose of laser pointers should be calibrated carefully before measuring the displacement. To calibrate the initial pose of the laser pointers, a specially designed jig device is made and employed. Experimental tests have been performed to validate the performance of the proposed calibration method and the results show that the estimated displacement with the initial pose calibration increases the accuracy of the 6-DOF displacement estimation.

Automatic and precise calibration of 4-channel cylindrical capacitive displacement sensor (4채널 원통형 정전용량 변위센서의 자동ㆍ정밀 검보정)

  • 김종혁;김일해;박만진;장동영;한동철;백영종
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.387-393
    • /
    • 2004
  • General purpose of cylindrical capacitive displacement sensor(CCS) is measuring run-out motion and deflection of rotor. If CCS has narrow sensing range, its sensitivity coefficients must be calibrated precisely. And x, y component of CCS output can be coupled. In this research, CCS calibration procedure is automated with automatic calibration program and PC-controlled stage. And, coupled-terms of CCS signals were removed and the errors between measured position and mapped CCS signal were reduced obviously by sensitivity matrix that linearly.

  • PDF

A Study on Calibrations of health monitoring system installed in Railway bridge (철도교 상시계측시스템의 센서교정방안 연구)

  • Lee Hyun Suk;Lee Jun Suk;Choi Il Yoon;Yim Myoung Jae
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.483-488
    • /
    • 2003
  • Calibration and gauge factor readjustment process made for the health monitoring system installed in the railway bridges is reviewed and some findings are explained in this study: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in details. Based on the regression results, new gauge factors are obtained from regression equation and another verification is made by performing another calibration again with new factors. From the second calibration, it was found that the suggested regression curves and their factors are appropriate and much better results are expected. Future work will be concentrated on the long-term analysis of the measurement data and on the database structures so that the assessment of the structure such as damage detection and remaining life estimation is possible.

  • PDF

A Study of Micro Displacement Measurement of Micro System using the Laser Interferometer (레이저 간섭계를 이용한 마이크로 시스템의 미소변위 측정에 관한 연구)

  • Choi, Kyung-Hyun;Kim, Chang-Jong;Cho, Su-Jeong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.2
    • /
    • pp.22-26
    • /
    • 2006
  • This paper addresses the development of a laser interferometer to measure micro displacement for a micro system. The laser interferometer is able to measure micro displacement during a few micro seconds with non-contact. In order to employ the interferometer, the displacement calibration experiment should be required. For the experiment, a laser probe installed on the optical table with optical devices and a micro stage. The velocity decoding board is also added to calculate doppler shift frequency directly. The output signal is processed by LabView. Finally experiments are found out the relation between displacement and output signal.

  • PDF

Calibration of Health Monitoring System installed in the Railway Bridges (철도교 상시계측시스템의 교정 및 교정상수 설정에 관한 연구)

  • 박준오;이준석;최일윤;민경주
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.148-157
    • /
    • 2002
  • A health monitoring system becomes a useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. The health monitoring system not only gives the direct measurement data of the railway bridges but also provides the basic data on the maintenance of the structures. Therefore, periodic calibrations of the health monitoring system will be a necessary step toward precise and accurate assessment of the railway bridges. In this study, the calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges is reviewed and some findings are explained in detail: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in full length. Based on the regression results, it was found that the gauge factors need to be readjusted according to the regression equation but, since the deviation or shift is not serious so far, long-term observation on each sensor is also recommended. Future work will be concentrated on the long-term analysis of each sensor and on the database creation so that the assessment of the structures is possible.

Primary vibration calibration by laser interferometry (레이저 간섭계를 이용한 진동 가속도계의 절대교정)

  • 이두희;이용봉;전병수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1356-1360
    • /
    • 2001
  • A number of calibration methods are described in ISO 16063 (revision of ISO 5347) and they may be used for special purposes. However, the use of a laser interferometer is recommended for primary calibration. This paper introduces the primary vibration calibration by measuring displacement amplitude and frequency using laser interferometry.

  • PDF

Application of Compensation Method of Motion Analysis Error Using Displacement Dependency between Anatomical Landmarks and Skin Markers Due to Soft Tissue Artifact (연조직 변형에 의한 해부학적 지표와 피부마커의 변위 상관성을 이용한 동작분석 오차 보정 방법의 적용)

  • Ryu, Taebeum
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.4
    • /
    • pp.24-32
    • /
    • 2012
  • Of many approaches to reduce motion analysis errors, the compensation method of anatomical landmarks estimates the position of anatomical landmarks during motion. The method models the position of anatomical landmarks with joint angle or skin marker displacement using the data of the so-called dynamic calibration in which anatomical landmark positions are calibrated in ad hoc motions. Then the anatomical landmark positions are calibrated in target motions using the model. This study applies the compensation methods with joint angle and skin marker displacement to three lower extremity motions (walking, sit-to-stand/stand-to-sit, and step up/down) in ten healthy males and compares their performance. To compare the performance of the methods, two sets of kinematic variables were calculated using different two marker clusters, and the difference was obtained. Results showed that the compensation method with skin marker displacement had less differences by 30~60% compared to without compensation. And, it had significantly less difference in some kinematic variables (7 of 18) by 25~40% compared to the compensation method with joint angle. This study supports that compensation with skin marker displacement reduced the motion analysis STA errors more reliably than with joint angle in lower extremity motion analysis.

Autonomous Calibration of a 2D Laser Displacement Sensor by Matching a Single Point on a Flat Structure (평면 구조물의 단일점 일치를 이용한 2차원 레이저 거리감지센서의 자동 캘리브레이션)

  • Joung, Ji Hoon;Kang, Tae-Sun;Shin, Hyeon-Ho;Kim, SooJong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.218-222
    • /
    • 2014
  • In this paper, we introduce an autonomous calibration method for a 2D laser displacement sensor (e.g. laser vision sensor and laser range finder) by matching a single point on a flat structure. Many arc welding robots install a 2D laser displacement sensor to expand their application by recognizing their environment (e.g. base metal and seam). In such systems, sensing data should be transformed to the robot's coordinates, and the geometric relation (i.e. rotation and translation) between the robot's coordinates and sensor coordinates should be known for the transformation. Calibration means the inference process of geometric relation between the sensor and robot. Generally, the matching of more than 3 points is required to infer the geometric relation. However, we introduce a novel method to calibrate using only 1 point matching and use a specific flat structure (i.e. circular hole) which enables us to find the geometric relation with a single point matching. We make the rotation component of the calibration results as a constant to use only a single point by moving a robot to a specific pose. The flat structure can be installed easily in a manufacturing site, because the structure does not have a volume (i.e. almost 2D structure). The calibration process is fully autonomous and does not need any manual operation. A robot which installed the sensor moves to the specific pose by sensing features of the circular hole such as length of chord and center position of the chord. We show the precision of the proposed method by performing repetitive experiments in various situations. Furthermore, we applied the result of the proposed method to sensor based seam tracking with a robot, and report the difference of the robot's TCP (Tool Center Point) trajectory. This experiment shows that the proposed method ensures precision.

New Calibration Methods for improving the Accuracy of AFM (원자간력 현미경의 자율교정법)

  • Kweon, Hyun-Kyu;Go, Young-Chae
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.48-52
    • /
    • 2001
  • In this paper presents an accurate AFM used that is free from the Z-directional distortion of a servo actuator is described. Two mathematical correction methods by the in-situ self-calibrationare employed in this AFM. One is the method by the integration, and the other is the method by inverse function of the calibration curve. The in situ self-calibration method by the integration, the derivative of the calibration curve function of the PZT actuator is calculated from the profile measurement data sets which are obtained by repeating measurements after a small Z-directional shift. Input displacement at each sampling point is approximately estimated first by using a straight calibration line. The derivative is integrated with reference to the approximate input to obtain the approximate calibration curve. Then the approximation of the input value of each sampling point is improved using the obtained calibration curve. Next the integral of the derivative is improved using the newly estimated input values. As a result of repeating these improving process, the calibration curve converges to the correct one, and the distortion of the AFM image can be corrected. In the in situ self-calibration through evaluating the inverse function of the calibration curve, the profile measurement data sets were used during the data processing technique. Principles and experimental results of the two methods are presented.

  • PDF