• Title/Summary/Keyword: Disinfection treatment

Search Result 372, Processing Time 0.026 seconds

Applying the Disinfecting Effects of Vinegar to Raw Vegetables in Foodservice Operations: A Focused Microbiological Quality Evaluation (급식소에서 이용되는 채소류의 식초수 소독의 적용을 위한 연구 - 미생물적 품질 평가를 중심으로 -)

  • Kim, Hyun-Jung;Kim, Heh-Young;Ko, Sung-Hee
    • Korean journal of food and cookery science
    • /
    • v.23 no.4 s.100
    • /
    • pp.567-578
    • /
    • 2007
  • This study was designed to provide basic data for the application and practical use of vinegar disinfection for raw vegetable preparation in foodservice operations. The test materials were washed and disinfected by three different methods(tap water washing, chlorine water disinfection, vinegar disinfection) and stored at $3^{\circ}C$ and $10^{\circ}C$ for 7 days. Then, their microbiological qualities were compared. Total plate counts increased over the course of the storage period, and all samples, except in the case of tap water washing, remained under the permitted limit until the 7th day of storage. In particular, vinegar disinfection showed the lowest increase in total plate counts(2.35${\sim}$4.03 log CFU/g). While the total plate counts of chlorine and vinegar disinfection were within the 6.00 limit of microbiological safety, the tap water washing treatment passed the permitted limit. The psychrotrophic counts increased steadily over the course of the storage period, and increased least at $3^{\circ}C$, however, the tap water washing showed the most drastic increase, while vinegar disinfection yielded the smallest increase.

Disinfection, Sterilization and Aseptic Technique for Thread Embedding Acupuncture (안전한 매선요법 시술을 위한 멸균, 소독 및 무균법)

  • Yun, Young-Hee;Son, Jae-Woong;Ko, Seong-Gyu;Choi, In-Hwa
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.1
    • /
    • pp.103-112
    • /
    • 2016
  • Objective : Thread embedding acupuncture has become popular as a minimally invasive treatment for facial wrinkles and laxity. However, there is little published clinical practice guidelines about disinfection, sterilization and aseptic technique for thread embedding acupuncture. This study is to introducing a specific guidelines about disinfection, sterilization and aseptic technique for thread embedding acupuncture.Method : We reviewed internal regulations and guidelines about hospital infection, and Traditional Korean medicine doctors, nurses, and director of central supply room discussed in depth and established a regulation of disinfection, sterilization and aseptic technique for thread embedding acupuncture.Result : The regulation of disinfection, sterilization and aseptic technique for thread embedding acupuncture consisted of ① management of supplies, ② guidelines of disinfection, sterilization, and reuse, ③ aseptic technique for thread embedding acupuncture.Conclusion : Microbial management is an essential element of medical care and quality. Traditional Korean medicine doctors will care for disinfection, sterilization, and this should not neglect to comply with the procedures and guidelines in the medical field as well as to understand the aseptic techniques.

Behavior of Organic Matter, Chlorine Residual and Disinfection By-Products (DBPs) Formation during UV Treatment of Wastewater Treatment Plant Effluents (하수처리장 방류수의 UV 처리시 유기물질, 잔류염소 및 소독부산물 생성 거동)

  • Han, Jihee;Sohn, Jinsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.61-72
    • /
    • 2014
  • Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.

The pollutants removal and disinfection of secondary effluent from sewage treatment plant in loop reactor using silver nanoparticles coated on activated carbon (은나노 활성탄을 이용한 Loop Reactor에서 하수 2차 처리수 중의 오염물질 제거 및 소독 효과)

  • Seon, Yong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.361-367
    • /
    • 2016
  • Pollutants removal and disinfection effect of secondary effluent from final settling tank of sewage treatment plant of W city were investigated in Loop Reactor using ordinary granular activated carbon(GAC) and GAC coated with silver nanoparticles. The results showed that the removal efficiency of $COD_{Mn}$, T-N and T-P using GAC with silver nanoparticles were higher than using the ordinary GAC. The removal efficiency of T-P using GAC with silver nanoparticles is 45.4% and that of T-P using ordinary GAC is 30.9% in the same case of the input amount of 20 g/L of GAC. The total califorms is reduced according to increasing input amount of GAC with silver nanoparticles and ordinary GAC. The disinfection efficiency of total coliforms in case of GAC with silver nanoparticles is much higher than that in case of ordinary GAC. For all experiments using the silver nanoparticles, the total coliforms is under 26 cfu/mL and this shows very excellent disinfection effect.

Application of Paraformaldehyde (Neo-PPS) Fumigation to the Disinfection of the Silkworm Larvae, Bombyx mori L., for the Control of Silkworm Diseases (II). Chemical Damage of Neo-PPS to the Silkworm Larvae (Paraformaldehyde(Neo-PPS)$\circledR$훈증에 의한 잠체소독에 관한 연구 II. 약해에 관한 시험)

  • 김근영;이재창
    • Journal of Sericultural and Entomological Science
    • /
    • v.24 no.1
    • /
    • pp.25-27
    • /
    • 1982
  • The use of fumigation of Neo-PPS was tested for the larval disinfection and at the same time for easy handling and effective chemicals for larval disinfection. The results obtained are as follows: 1. There was no decrease of cocoon yield in spring season due to chemical damage by application of Neo-PPS fumigation to the disinfection of the silkworm except 2,4 and 6 hours' treatment everyday and 6 hours'/ twice/instar treatment as compared with the control. 2. There was no significance in pupal percent between treatments and control in spring season except 6 hours' treatment everyday. 3. No chemical damage seemed to give rise to percentage of cocoon shell in all treatments.

  • PDF

Analysis of Disinfection Performance of UV LEDs for a Phytoplankton (식물성 플랑크톤에 대한 UV LED의 살균성능 분석)

  • Kil, Gyung-Suk;Choi, Sung-Kuk;Park, Dae-Won;Kim, Sung-Wook;Cheon, Sang-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.959-964
    • /
    • 2009
  • This paper dealt with the disinfection performance by Ultra-Violet Light Emitting Diode (UV LED) for a phytoplankton as a basic study for the development of a low-energy consumption ballast water treatment system. UV LEDs having peak wavelength of 255nm, 265nm and 280nm were used in the experiment. UV LED modules with driving circuit were fabricated, and optical and electrical characteristics of them were analyzed. The disinfection performance for phytoplankton depending on the UV wavelength was evaluated by comparing the number of phytoplankton before and after the UV treatments. The experimental result showed that the highest disinfection wavelength for the phytoplankton was 265nm.

Assessment of Hot Water Treatment and Lime Sulfur Mixture on Germination and Disinfection Efficacy of Organic Wheat Seeds (온탕침지법과 석회유황합제 처리가 유기농 밀 종자의 발아와 소독효과 미치는 영향 평가)

  • Min-Jeong Kim;One-Sung Park;Chang-Ki Shim;Jae-Hyeong Lee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.4
    • /
    • pp.371-382
    • /
    • 2023
  • This study aimed to estimate optimal treatment for enhancing the germination rate and disinfections effect of organic wheat varieties, Jokyung, Geumgang, Saegumgang, and Baekgang using hot water treatment and lime sulfur mixture. Before disinfection, the germination rates of the seeds averaged 86.3±2.5% to 87.5±2.9%, while the infection levels caused by fungi and bacteria were observed to be 22.5±2.9% to 38.3±2.5% and 18.8±4.8% to 23.8±2.5%, respectively. The germination rates of four wheat varieties under hot water treatments were either the same or higher compared to untreated seeds. As the temperature and treatment time of hot water treatment increased, the contamination levels of fungi and bacteria decreased. The optimal hot water treatment for the seeds was observed at 55℃ for 10 minutes, resulting in germination rates averaging 90.0±0.0% to 97.5±2.9%, which were either the same or higher than untreated seeds. The disinfection effectiveness against fungi and bacteria was high, averaging 83.3~93.5% and 100%, respectively. Additionally, an investigation was conducted on the germination rates and microbial disinfection efficacy of 0.2% and 0.4% lime-sulfur mixture with varying treatment times, 3 to10 minutes for each wheat variety. As the treatment time elapsed, no significant differences in germination rates were observed among four wheat varieties. However, the germination rates were higher compared to the untreated group (86.3~87.5%), and the optimal treatment time was found to be 7 minutes or 10 minutes, resulting in an average reduction of 90.0~96.0% in contamination levels of fungi and bacteria. Therefore, the germination rates and disinfection effects varied depending on the treatment conditions of hot water treatment and lime-sulfur mixture applied for the disinfection of the four varieties of organic wheat seeds. However, it is considered that treating the seeds with hot water treatment at 55℃ for 10 minutes or with 0.2% or 0.4% lime-sulfur compound for 10 minutes enhances germination rates and reduces the contamination rate of fungi and bacteria compared to untreated seeds. Thus, these environmentally friendly seed disinfection technologies are likely to be highly useful in agricultural fields.

Electrochemical Disinfection for Ballast Water Treatment (발라스트수 처리를 위한 전기화학적 살균처리)

  • Seo, Won-Hak;Jeon, Sun-Ae;Kim, Ji-Hyun;Lee, Tae-Ho;Sang, Byoung-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1162-1167
    • /
    • 2006
  • The discharge of ballast water from the marine vessel without proper treatment causes the ecological disruption. Therefore, International Marine Organization(IMO) has the plan to force the proper treatment of ballast water before its discharge to open sea. To satisfy the IMO's criteria, several processes such as filtration, UV irradiation, and ozonation etc., were introduced. Since the disinfection of ballast water should be conducted within very short hydrolic retention time, electrochemical treatment can be a promissing process. The DSA(dimensional stable anode) electrode for the electrochemical treatment was prepared by thermal deposition method. The disinfection rate of microorganisms increased with the increasing current density and reaction time under low pH condition. The morphology of sterilized microorganisms was shown by SEM and Microscopy.

Disinfection effects of heat- and cold-treatment and UV-irradiation on campylobacter jejuni (고온 및 저온처리와 자외선조사에 의한 campylobacterjejuni의 살균효과)

  • 김치경;임선희;윤만석;오학식;조민기
    • Korean Journal of Microbiology
    • /
    • v.27 no.3
    • /
    • pp.291-296
    • /
    • 1989
  • Campylobacter jejuni was studied for its disinfection by heat-and cold-treatment and UV-irradiation. When C. jejuni was treated by heat, no viable cell was found after 10 min treatment at $55^{\circ}C$, whereas small fraction of cell population was survived after 60 min treatment at $45^{\circ}C$ and $50^{\circ}C$. When they were treated by cold temperature for 30 days, no cell was survived at -$23^{\circ}C$ but about 4 log of the cells were survived at both temperature of $4^{\circ}C$ and -$40^{\circ}C$. When the organisms were UV-irradiated, thier survival rates were proportionally varied to the distance of irradiation. The scanning electron microscopic studies of C. jejuni cells treated by the disinfecting agents revealed that shapes of thecells were deformed from spiral rod into spherical form. The heat-treated cells showed rough and damaged surface on the scanning electron micrographs. In the heat-treated cells, some proteins of high molecular weight appeared to become accumulated in the electrophoretic analysis. The DNAs extracted from the cells treated with the physical agents showed some differences in agarose gel electrophoresis, comparing those of normal cells.

  • PDF

Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System (소독부산물 최소화를 위한 운영조건 연구)

  • Shin, Hyung-Soon;Choi, Phil-Kweon;Kim, Jong-Su;Choi, Ill-Woo;Kim, Sang-Hoon;Kim, Tae-Hyun;Lee, Kyung-Hee;Lee, Soo-Moon;Jang, Eun-Ah;Jung, Yeon-Hoon;Kim, Jung-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.