• Title/Summary/Keyword: Disinfection treatment

Search Result 372, Processing Time 0.028 seconds

Pythium myriotyrum에 의한 생강뿌리썩음병의 포장내 발병진전에 미치는 토양소독, 살균제 시용, 좁은 이랑재배 효과

  • 김충희;양성석;한기돈
    • Korean Journal Plant Pathology
    • /
    • v.14 no.3
    • /
    • pp.253-259
    • /
    • 1998
  • Effects of soil disinfection, fungicide application, and narrow ridge cultivation on ginger rhizome rot development were examined in two naturally-infested fields at Seosan, Choongnam province. Soil disinfection treatments were assigned to main plots, and fungicide and ridge treatments to sub-plots in a split plot design with three replications. The rhizome rot started in late July, and progressed rapidly until late September with the peak incidence in mid-august to early September. Soil disinfection by dazomet application showed the most prominent inhibition effects in both fields, where the disease was reduced by the treatment from 17.5% to 4.8% in one field, and from 51.0% to 2.2% in the other field. Three to five applications of fungicide metalaxyl-copper during the growing season inhibited the disease by 89.7% in one field, but less effectively in the other field. Narrow ridge cultivation reduced the disease effectively by 78.1% and 63.9%, compared to the unridged control plots in each field, respectively. Germination rate of seed-rhizomes and growth of ginger plants were similar between treatments, except when the plots received improper aeration after applying dazomet, and then the germination rate was significantly reduced. The greatest yields were obtained in the disinfected plots, regardless of rhizome rot incidence, except one control plot with very little disease. Ginger yield was negatively correlated with disease severity. However, the yield of ridge plots averaged 58∼59% compared to those of the unridged plots, due mainly to the half planting rate of the ridge plots. In spatial progress, the disease in the disinfected plots started from a single focus of the inoculum, and spread into the adjacent areas only, whereas in the untreated plots, the disease started from many foci that were distributed over the plot, and rapidly progressed to make an epidemic during the season. The soil density of P. myriotylum in the disinfected plots was not changed or, if not, increased slightly during the season. However, in the untreated plots it increased rapidly to reach the density 3 to 5 times greater by the end of the season.

  • PDF

A Study of Treatment Efficiency of Reflectors for CSOs Disinfection by Pulsed UV (Pulsed UV를 이용한 CSOs 소독시 반사체에 따른 처리효율 연구)

  • Han, Jonghun;Hur, Jiyong;Kim, Kangwook;Lee, Junyoung;Park, Wonseok;Lee, Jongyeol;Her, Namguk
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.36-40
    • /
    • 2015
  • This study examined the disinfection in combined sewer overflows (CSOs) by pulsed ultraviolet (PUV). The reflectors (stainless steel. mirror, aluminium foil, aluminium (1050), aluminium (6061), aluminium (5052), and aluminium mirror) of PUV irradiation was performed in a 90 L stainless reactor at a constant temperature of $20^{\circ}C$ and an applied power of 4000 W. The reflection efficiency of reflectors were showed 1.00 (aluminium mirror) ~ 1.48 (aluminium foil) does. The case of a rough surface analysis using SEM showed high reflectance, was the case of a smooth surface and a low reflectivity. Pseudo first-order rate constant calculated results, has a higher reflectivity values were more than twice as high compared to the low reflectivity. Affected Total coliforms disinfection time, depending on the type of reflector is considered.

Effect of Chlorination on Disinfection Byproducts Production and Release of Microcystins from Bloom-forming Algae (녹조현상 원인조류들의 염소처리에 의한 소독부산물 생성 및 microcystins 유출)

  • Park, Hae-Kyung;Seo, Yong-Chan;Cho, Il-Hyung;Park, Byung-Hwang
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.513-520
    • /
    • 2006
  • The effect of chlorination on disinfection byproducts (DBPs) production from bloom-forming freshwater algae including 7 strains of cyanobacteria and 6 strains of diatoms was investigated. The release and degradation of hepatotoxin (microcystins) by the chlorination on Microcystis under differential condition of the chlorination time and dose were also investigated. The disinfection byproducts formation potentials (DBPFP) of cyanobacterial species and diatoms were ranged from 0.017 to $0.070{\mu}mol\;DBPs/mg$ C and from 0.129 to $0.708{\mu}mol\;DBPs/mg$ C respectively. Among three major groups of DBPs, haloacetonitrils (HANs) was major product in most test strains except Aphanizomenon sp. and Oscillatoria sp. Haloacetic acids (HAAs) was less than 5 % of total DBPs. Chloroform and dichloroacetonitril (DCAN) were dominant compounds in trihalomethanes (THMs) and HANs respectively. After 4 hours chlorination of toxic Microcystis aeruginosa under the dose range of 0.5 to $10mg\;Cl_2/L$, the concentration of intracellular microcystins decreased, but dissolved dissolved microcystins concentration increased with the treatment of more than $3mg\;Cl_2/L$. However the total amount of microcystins was almost constant even at $10mg\;Cl_2/L$ of chlorination. To conclude, our results indicate that the chlorination causes algal cell lysis and release of intracellular microcystins in the intact form to surrounding waters.

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF

The Characteristics of Disinfection by-products Occurrence and Speciation in D Water Treatment Processes (D 정수처리장에서 소독부산물 발생 및 종분포 특성)

  • Kim, Sung-Joon;Kim, Jong-Min;Jeon, Yong-Tae;Park, Jong-Eun;Won, Chan-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.406-412
    • /
    • 2010
  • Concentrations and speciations of Trihalomethanes (THMs) and Haloacetic acids ($HAA_5$) that can be formed during chlorine disinfection by-product (DBPs) in full-scale drinking water treatment plants were investigated. Jeon-ju D water treatment plant that adopted conventional water treatment processes was chosen for investigation. SUVA values according to water treatment process changes were observed from 1.3 to 2.1. The process average concentrations of THMs was 7.4 ppb, 9.0 ppb and 14.7 ppb respectively, while the average concentrations of $HAA_5$ by each process which are precipitation water, filterater water, treated water, were 15.5 ppb, 14.9 ppb and 25.8 ppb respectively. DBPs concentrations was lower in the winter than summer. The major species of THMs was chloroform and the second highest was bromodichloromethane (BDCM) and the third highest was dibromochloromethane (DBCM). In case of $HAA_5$, the rate of trichloroacetic acid (TCAA) was detected. The species disribution of THMs is related to the change of SUVA and species disribution of $HAA_5$ is related to the concentrations of bromine and injection position of chlorine and injection quantity.

Characteristics of Disinfection and Removal of 2-MIB Using Pulse UV Lamp (펄스 UV 램프를 이용한 미생물 소독 및 2-MIB 제거 특성)

  • Ahn, Young-Seog;Yang, Dong-Jin;Chae, Seon-Ha;Lim, Jae-Lim;Lee, Kyung-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.69-75
    • /
    • 2009
  • The characteristics of disinfection and organic removal were investigated with pulse UV lamp in this study. The intensity and emission wavelength of pulse UV Lamp were compared with low pressure UV lamp. The emission spectrum range of pulse UV lamp was between 200 and 400 nm while the emission spectrum of low pressure UV lamp was only single wavelength of 254nm. 3 Log inactivation rate of B. subtilis spore by pulse UV and low pressure UV irradiation was determined as $44.71mJ/cm^2$ and $57.7mJ/cm^2$, respectively. This results implied that wide range of emission spectrum is more effective compared to single wavelength emission at 254nm. 500ng/L of initial 2-MIB concentration was investigated on the removal efficiency by UV only and $UV/H_2O_2$ process. The removal efficiency of UV only process achieved approximately 80% at $8,600mJ/cm^2$ dose. 2-MIB removal rate of $UV/H_2O_2$ (5 mg/L $H_2O_2$) process was 25 times increased compared to UV only process. DOC removal efficiency for the water treatment plant effluent was examined. The removal efficiency of DOC by UV and $UV/H_2O_2$ was no more than 20%. Removal efficiency of THMFP(Trihalomethane Formation Potential), one of the chlorination disinfection by-products, is determined on the UV irradiation and $UV/H_2O_2$ process. Maximum removal efficiency of THMFP was approximately 23%. This result indicates that more stable chemical structures of NOM(Natural Organic Matter) than low molecule compounds such as 2-MIB, hydrogen peroxide and other pollutants affect low removal efficiency for UV photolysis. Consequently, pulse UV lamp is more efficient compared to low pressure lamp in terms of disinfection due to it's broad wavelength emission of UV. Additional effect of pulse UV is to take place the reactions of both direct photolysis to remove micro organics and disinfection simultaneously. It is also expected that hydrogen peroxide enable to enhance the oxidation efficiency on the pulse UV irradiation due to formation of OH radical.

Clinical evaluation of full mouth disinfection therapy (Full mouth disinfection therapy의 단기간 임상 효과 연구)

  • Cho, Ik-Hyun;Jung, Ui-Won;Cha, Jeong-Heon;Kim, Joong-Su;Lee, Dae-Sil;Kim, Chang-Seong;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.597-608
    • /
    • 2005
  • The aim of this study is to determine whether full-mouth disinfection therapy(FMT) in our clinical setting would show better improvement of clinical parameters than partial mouth disinfection therapy(PMT) in chronic periodontitis and aggressive periodontitis patients. Among 12 patients, 6 were treated FMT and other 6 were treated PMT. Clinical parameters were calculated 3 months and 6 months after initial therapy. 1. There were no statistically significant differences between FMT and PMT in the reduction rate of bleeding on probing after 3 months, 6 months 2. Initial probing depth was 4-6mm, the mean probing depth after 3 months was 2.2mm vs 2.5mm(FMT vs PMT), after 6 months was 2.4mm vs 2.8mm. This was significantly lower in the FMT groups. 3. Initial probing depth was ${\geqq}$ 7mm, the reduction rate of mean probing depth during first 3 months was 4.8mm vs 4.1mm(FMT vs PMT), and 3 to 6 months was 0.5mm vs 0.3mm. This was significantly larger in the FMT groups. 4. Initial probing depth was 4-6mm, the mean clinical attachment level after 3 months was 2.3mm vs 2.7mm(FMT vs PMT), after 6 months was 2.7mm vs 3.0mm. This was significantly lower in the FMT groups. 5. Initial probing depth was ${\geqq}$ 7mm, the reduction rate of mean probing depth during first 3 months was 4.0mm vs 3.0mm(FMT vs PMT), and 3 to 6 months was 0mm vs -0.1mm. This was significantly larger in the FMT groups. Although the results provided us with succeccful clinical improvement in aggressive periodontitis, further research is needed to prove its additional benefit in the treatment of chronic periodontitis

Development of an UV Distribution Model for the Design of a Submerged UV Disinfection Reactor and Its Application (침지형 자외선 살균조 설계를 위한 자외선 분포 모델의 개발 및 적용)

  • Park, Changyeun;Kim, Sunghong;Choi, Younggyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.505-512
    • /
    • 2021
  • A 3D model was developed to calculate the UV intensity of a submerged-type UV disinfection reactor. Numerical experiments were conducted by inputting the design factors of an open channel-type disinfection reactor and a pipe-type disinfection reactor that were installed in an actual sewage treatment plant. The following data were obtained: The average UV intensity of the installed open channel-type reactor and pipe-type reactor was 7.87 mW/cm2 and 13.09 mW/cm2, respectively; the UV dose reflecting the UV irradiation time and taking into account attenuation effects such as mixing imbalance, lamp aging, temperature, and fouling, was expected to be 21.1 mJ/cm2 and 24.8 mJ/cm2, respectively, and these values are 5 % and 24 % higher than the target UV dose of 20 mJ/cm2, respectively. By using the UV3D model, the optimal lamp position, which maximizes the average UV intensity without changing the size of the disinfection reactor or lamp output power, can be found. In this case, by only adjusting the lamp position, the average UV intensity can be increased by 0.9 % for the open channel-type and 0.5 % for the pipe-type, respectively. A better average UV intensity can be obtained by model simulation. By adjusting the horizontal and vertical ratio of the open channel-type reactor and by moving the lamp position, the average UV intensity can be increased by 7.4 % more than the present case.

A study on infection control practices by dental hygienists (치과위생사의 감염관리 실태 조사연구)

  • Nam, Sang-Mi
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.137-148
    • /
    • 2011
  • Objectives : The objectives of this study were to investigate the infection control practices of practicing dental hygienists. Methods : This research was based on self-filling survey which 149 dental hygienists in dental clinic and dental hospital on October 2009. For the data analysis, an SPSS WIN 11.5 program was used and its signification level was 0.05. The following shows the results of this study. Results : 1. There was significant difference in there practice about sterilization and disinfection of dental instrument depending upon the respondent' career(p<0.05). 2. There was significant difference to were gloves and a apron according to type of service(p<0.05). 3. There was significant difference in the time to change the gown according to experience of education factors infection control(p<0.05). Conclusions : The majority of dental hygienists surveyed reported altering infection control practices and treatment techniques. While there has been an improvement in compliance with recommended infection control guidelines. Even though there is a need for continuing infection control education for dental hygienists.

Case study on Remodeling Clearwell Hydraulic Structure using Transient CFD Simulation Technique (Transient CFD 모사기법을 이용한 정수지 최적설계 사례연구)

  • Kim, Seon-Jin;Kim, Seong-Su;Park, No-Suk;Cha, Min-Whan;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.425-432
    • /
    • 2010
  • From the results of tracer test for the existing clearwell in Y water treatment plant, $T_{10}$ and T10/T were calculated as 150 min and 0.24, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by $T_{10}$ and $T_{10}$/T, and disinfection performance. In this study, using transient CFD(Computational Fluid Dynamics) simulation technique, tracer tests on dynamic condition for the suggested schemes were simulated. From the results of simulation, it was revealed that 8~6 baffles are necessary to guarantee the disinfection ability in the existing clearwell. Also, installing orifice baffle in the vicinity of inlet could increase plug flow fraction within clearwell.