• Title/Summary/Keyword: Disinfection rate

Search Result 164, Processing Time 0.025 seconds

A Study on Escherichia Coli Disinfection by the Electrochemical Method for Small Sewerage System (소규모 오수처리를 위한 전기화학적 방법에 의한 대장균 소독에 관한 연구)

  • Park, Young-Seek;Jeong, No-Sung;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.441-447
    • /
    • 2007
  • This study was carried out to investigate the effect of electrochemical (EC) disinfection of artificial wastewater contaminated by Escherichia coli culture. Circulated batch type electrochemical disinfection system using three plates electrodes was used. Also, the several factors (pH, ORP, DO, temperature, current, conductivity) were measured in order to investigate the fundamental design factor in the EC disinfection system. It was demonstrated that the EC process was highly effective for wastewater disinfection. At the constant voltage, the disinfection efficiency was increased according to time. The disinfection efficiency and current increased as the increase of voltage. The variation of conductivity was a little related to the variation of CFU (colony forming units). The differences in disinfection efficiency according to the ice pack and the variation of electrodes were not occurred. The EC disinfection efficiency and current increased according to the increase of circulating flow rate.

Disinfection Characteristics of Waterborne Pathogenic Protozoa Giardia lamblia

  • Kim, Kyongjoo;Wooksun Hong;Lee, Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.2
    • /
    • pp.95-99
    • /
    • 2001
  • Giardia lamblia is a parasitic protozoa which is transmitted in the form of a cyst through untreated water and also treated drinking water. Since its presence in water has led to frequent outbreaks of giardiasis and death in many countries, the removal and disinfection of this protozoan cyst from the water supply are of great concern for public health. This study examined the disinfection characteristics of G. lamblia cysts isolated from a Korean patient with giardiasis. When using sodium hypochlorite including 5 or 10 ppm chlorine, the killing rate was initially rapid, however, the disinfection slowed down and a 3log reduction could not be achieved even after 2h. The disinfection effectiveness was also reduced at a lower temperature, thereby implying that the risk o a giardiasis outbreak will be higher in the winter season. A CT (concentration$.$time) curve was constructed based on the results with sodium hypochlorite for use in designing and predicting disinfection performance. The organic chlorination disinfectant SDIS (sodium dichloroisocyanurate) produced a lower pH and a much higher residual effect than sodium hypochlorite. The disinfection of cysts by SDIC continued steadily throughout 2h of contact, although the initial killing rate was lower than that with sodium hypochlorite.

  • PDF

Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier (초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구)

  • Kim, Seunga;Kim, Jihyun;Lee, Minjoo;Kim, Jayun;Jung, Woosik;Park, Joonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.227-235
    • /
    • 2021
  • This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

The Evaluation of Effectiveness of Belt-type Hand Sanitizers in Clinical Nurses: Focusing on the performance of hand disinfection and the satisfaction (벨트형 손소독제 활용의 효과 평가: 임상간호사의 손소독 수행 정도와 만족도를 중심으로)

  • Cho, Yoonju;Lee, Insook
    • Journal of Digital Convergence
    • /
    • v.18 no.3
    • /
    • pp.275-285
    • /
    • 2020
  • The aims of this study was to examine the effect on the hand disinfection performance, the performance rate, and the satisfaction with the use of the belt-type hand sanitizers in clinical nurses. The study is a one group pre-post test quasi-experimental design. Effectiveness of using the belt-type hand sanitizers was measured with a self-reporting questionnaire. As a result, the performance of hand disinfection and the performance rate were significantly higher after using the belt-type hand sanitizers, and also, the satisfaction with the use of the belt-type hand sanitizers was significantly high. The belt-type hand sanitizer is effective method to improve both hand disinfection performance and its performance rate. Therefore, if the belt-type hand sanitizer is used in clinical practice, it may contribute to the improving the hand disinfection performance and its performance rate.

Effect of UV disinfection following mechanical filtration for influent seawater on decrease in disease outbreak of juvenile olive flounder (Paralichthys olivaceus) (유입수의 기계적 여과 후 자외선 살균에 의한 넙치 치어의 질병 저감 사례 연구)

  • Kang, Bong-Jo;Jang, Yeoung Hwan;Jhon, Bong Kun;Park, Byum Hee;Shin, Dong Hyuk
    • Journal of fish pathology
    • /
    • v.28 no.3
    • /
    • pp.125-131
    • /
    • 2015
  • This study was performed to determine the disinfection efficacy of influent seawater by application of mechanical filtration and UV disinfection system (MFUVDS) in decreasing disease outbreak of juvenile olive flounder (Paralichthys olivaceus). Bacterial disinfection rate of influent seawater following the MFUVDS application was 99.27%. Mortalities of the juvenile reared for 4 months were 20~30% lower than those of the control (25.8%~34.9%).

Kinetic analysis of E. coli disinfection using UV-LED (LED 광원 UV에 의한 대장균(E. coli) 소독의 속도론 해석)

  • Kim, Kyeong-Rae;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.489-496
    • /
    • 2021
  • Water disinfection using UV-LED(Light emitting diode) has many advantages, such as smaller footprint and power consumption as well as relatively longer lifespan than those of conventional mercury-UV lamps. Moreover, UV-LED disinfection is considered an environmentally benign process due to its mercury-free nature. In this study, disinfection using an LED module emitting 275nm UV was carried out. 384 UV-LEDs were put into a cylinder tube with a capacity of 1.7 liters. The UV intensity of the UV-LED module was controlled from 1.7 to 8.4 mW/cm2. The disinfection efficiency for the model microorganism solutions(E. coli ) was monitored. As the UV intensity(I) and contact time(t) varied, inactivation of the microorganisms from 2 to 4-log-removals(i.e., 99 to 99.99% of disinfection efficiency) was achieved. Disinfection using UV-LED was followed to 1st order reaction and the reaction rate constant, k was determined. In addition, the relationship between UV intensity(I) and contact time(t) in order to obtain 99.99% of disinfection efficiency was modeled: I1.2·t= 460, which indicates that the product of UV intensity and contact time requiring 4-log-removals is always constant.

E. coli Disinfection Using a Multi Plasma Reactor (멀티 플라즈마 반응기를 이용한 E. coli 소독)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.2
    • /
    • pp.187-195
    • /
    • 2013
  • Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and $UV_{254}$ absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, $UV_{254}$ absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

Inactivation of Seawater Zooplankton Aretemia sp. using Physical and Chemical Processes (물리·화학적 공정을 이용한 해수 동물성 플랑크톤 Aretemia sp.의 소독)

  • Zheng, Cheng;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.24 no.9
    • /
    • pp.1181-1188
    • /
    • 2015
  • In this study, we discussed about the application of the single physical and chemical treatment processes and the physical-chemical complex treatment processes on the inactivation of Artemia sp. in order to satisfy the USCG Phase II (United States Coast Guard). The results showed that initial disinfection rate of ultrasonic process in single batch process is higher than that of electrolysis. However, the inactivation rate showed slower than electrolysis. The inactivation rate of Artemia sp. on the single continuous treatment process ranked in the following order: homogenizer > electrolysis > ultrasonic process. Inactivation rate of Artemia sp. in continuous homogenizer-electrolysis complex process was reached at 100% immediately. A synergistic effect of ultrasonic-electrolytic complex process was found to be a small. The order of processes in a complex process did not affect the disinfection performance.

Disinfection of Water by Ultrasonic Irradiation (초음파 검사에 의한 수중의 살균처리)

  • 손종렬;유병성
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The industrial techniques of ultrasound have been used in the various fields, such as cleaning, medical surgery, emulsification, cell disruption etc. Especially the application of cell disruption was interested in the field of disinfection process in water by ultrasonic irradiation. It has been recognized that the ultrasounds are irradiated in aqueous solution, cavitation bubbles are generated and shock waves of high temperature and pressure are emitted as the bubbles are developed and finally broken, which function as a energy source to promote reaction efficiencies of various kinds of chemical reactions such as disinfection reaction in water. Therefore, this study was performed to apply the ultrasound for the disinfection method of infected drinking raw water and to discuss the limiting factors such as pH, sample volume and reaction temperature influenced on the removal efficiency of E. coli from experimental analysis of the results obtained in bench-scale plant. For the experiments to measure the influence of reaction parameters in the ultrasonic disinfection process, escalated reactivity of aqueous solutions was excellent when pH in aqueous solution was low, and sample volume was small. On the contrary, the reactivity of disinfection became elevated when reaction temperature was high. It was found that the rate constant of disinfection reaction was applied by Chick's law, reaction kinetics of Chick's law was irreversible and pseudo-first order at all the tested conditions.As a conclusion it appeared that the technology using ultrasonic irradiation can be applied to the treatment of disinfection in infected water which are difficult to be treated by conventional methods.

  • PDF

A Comparison of Single Disinfection Process for Inactivation of E. coli (E. coli 불활성화를 위한 단일 소독 공정의 비교)

  • Kim, Dong-Seog;Song, Seung-Koo;Park, Young-Seek
    • KSBB Journal
    • /
    • v.25 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • This study was carried out to evaluate the performance of three kinds of single process (electrolysis, UV and ultrasonic process) for the purpose of disinfection of Escherichia coli in water. Among the five kinds of electrode material, disinfection performance of Ir electrode was higher than that of the other electrodes. The order of disinfection performance for E. coli in single process lies in: electrolysis > UV $\gg$ ultrasonic process. Performance of the three single processes was increased with the increase of the electric power. Disinfection efficiency of the three processes was increased with the decrease of the pH. Disinfection of the UV process were decreased by the increase of NaCl dosage and air flow rate. However, ultrasonic process was not affected above two parameters. OH radical was not produced in UV and ultrasonic process. E. coli disinfection of the electrolysis process was well agreed with RNO degradation tendency, except pH.