• Title/Summary/Keyword: Disinfection facility

Search Result 28, Processing Time 0.029 seconds

Physical and Biological Performance Evaluation of Disinfection Systems for Transportation Vehicles against AI Virus

  • Chung, Hansung;Choi, Kwanghoon;Kim, Sungkwan;Kim, Sukwon;Lee, Kyungwoo;Choe, Nonghoon
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.7
    • /
    • pp.956-966
    • /
    • 2021
  • To prevent the outbreak of infectious diseases that inflict huge economic and social losses, domestic livestock farms and related facilities have introduced automatic and semiautomatic disinfectant solution-spraying systems for vehicles. However, the facility standards and specifications vary by manufacturer, and no scientific performance evaluation has been conducted. The puropose of this study is to develop physical and biological evaluation methods. Physical and biological appraisals were conducted using two types of disinfection facilities (tunnel- and U-type) and two types of vehicles (passenger car, truck). Water-sensitive paper was used to evaluate the physical performance values for the disinfection facilities. In addition, to assess their biological performance, carriers containing low-pathogenic avian influenza virus were attached to vehicles, and the viral reduction was measured after the vehicles moved through the facility. The tunnel-type had rates of coverage in the range of 70-90% for the passenger car and 60-90% for the truck. At least 4-log virus reduction after spraying for 1-5 min was shown for both vehicles. For the U-type facility evaluation, the coverage rates were in the range of 60-90% for the passenger car and at least 90% for the truck. More than 4-log viral reduction was estimated within a spraying time of 5 min. To reduce viruses on the surface of vehicles by at least 4 log within a short period, the disinfectant solution should cover at least 71% of the pathogens. In conclusion, we were able to assess the physical and biological performance criteria for disinfection facilities aboard transportation vehicles.

Characteristics of Disinfection Performance in Water Treatment Plants with Introducing Treatment Technigue Requirement (정수 처리기술 기준 도입을 앞둔 전국 정수장의 소독능 관리 현황 및 특색)

  • Yeom, Cheolmin;Cho, Soonhaing;Jung, Haewoong;Yoon, Jeyong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.327-336
    • /
    • 2002
  • Disinfection process in water treatment plants (WTPs) is one of the most important step in order to inactivate waterborne disease. However, what is the necessary disinfection in WTPs was not properly established in Korea. This study was conducted to evaluate disinfection performance in nationwide water treatment plants (n=474). Disinfection requirement based on the SWTR (Surface Water Treatment Rule) of the U.S. (1-log Giardia removal) was chosen in estimating the compliance. The scope of unit process for evaluating disinfection performance includes postdisinfection process in clearwells, pipeline, and storage tank. The worst water quality condition in individual WTPs was applied for the disinfection performance evaluation. The major results are as follows. First, it was appeared that 184 WTPs (39 %) provided insufficient disinfection performance. Disinfection performance was significantly improved during past 2 years. The ratio of the number of WTPs providing insufficient disinfection performance in 1999 and 2001 was 78 % and 41 %, respectively. One of major factors for this improvement was due to the improvement of $T_{10}/T$ value in clearwell, as a result of modification of clearwell facility. Second, if disinfection criteria is 3-log Giardia inactivation at worst water quality condition, then 19 % of all WTPs can not meet this disinfection criteria. And if disinfection criteria is strengthened to 4-log Giardia inactivation, then 58 % of all WTPs can not meet this disinfection criteria. Since disinfection criteria is decided by contamination level of Giardia in source water, it also needs the investigation of Giardia occurrence in source water.

Biotechnological Potential of Marine Cyanobacteria in Wastewater Treatment: Disinfection of Raw Sewage by Oscillatoria willei BDU130511

  • Uma, L.;Selvaraj, K.;Manjula, R.;Subramanian, G.;Nagarkar, Sanjay
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.4
    • /
    • pp.699-701
    • /
    • 2002
  • The current study demonstrates the ability of the marine cyanobacterium Oscillatoria willei BDU130511 to disinfect raw sewage. Within a holding time of 3 h under laboratory conditions, the organism drastically reduced in the total bacterial and coliform counts at various pH levels, in both unbuffered and buffered sewage, thereby suggesting a potential role for cyanobacteria in wastewater treatment.

Design and Implementation of Disinfection Service Platform based on MVC Pattern Using Web/App

  • Jang, Ye-jin;Jo, Yu-min;Shin, Ji-in;Jang, Yun-jeong;Jeong, Da-woon;Paik, Jong-ho
    • Journal of Internet Computing and Services
    • /
    • v.22 no.6
    • /
    • pp.41-49
    • /
    • 2021
  • Due to the COVID-19 pandemic, issues related to quarantine are emerging. There are various infection prevention methods, but among them, it is certain to frequently disinfect the surface or the entire space of an object that has come into contact with the virus. However, the reality is that the number of times such disinfection is legally designated and the required number of personnel are very different depending on the building and facility. For this reason, there are no companies and systems that can professionally receive orders for disinfection work. In order to solve the aforementioned problems, this paper presents a method to design a disinfection service platform based on the MVC pattern, and implements the required functions based on this. Through this, it is possible to build a more systematic system, and it is hoped that it will be of great help to quarantine with an orderly process for disinfection work.

Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System (공급과정 수질개선을 위한 잔류염소 균등화 효과분석)

  • Choi, Taeho;Lee, Doojin;Bae, Cheolho;Moon, Jiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

Analysis of Disinfection Practices in Foodservice Operations According to the Application of Hazard Analysis and Critical Control Point (식품안전관리인증기준 적용 여부에 따른 급식시설의 소독 실태 분석)

  • Park, Min-Seo;Lee, Hye-Yeon;Bae, Hyun-Joo
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.103-110
    • /
    • 2021
  • This study was conducted to compare and evaluate the difference in washing and disinfection when the Hazard Analysis and Critical Control Point (HACCP) protocol was applied to foodservice operations. The results of the survey were as follows: Among the 116 foodservice operations surveyed, 67.2% were HACCP-compliant and 32.8% were not HACCP-compliant. Also, 62.9% served meals once daily, and 79.3% conducted food safety education once a month. Compared to HACCP non-compliant foodservice operations, the disinfection performance of HACCP-compliant operations was significantly better concerning worktables (p<0.001), food inspection tables (p<0.001), preparation tables for distribution (p<0.01), serving tables (p<0.01), overflow and trenches(p<0.05), sinks (p<0.05), and insect attracting lamps (p<0.01). Similarly, the disinfection performance of HACCP-compliant foodservice operations was significantly better for 18 cooking utensils and personal tools such as food slicers (p<0.001), multiple cooking machines (p<0.05), tray carts (p<0.001), stainless steel tools (p<0.001), rubber gloves (p<0.05). Worktables (45.1%), serving tables (29.6%), sinks (37.0%), and scales (21.6%) were most often disinfected 'at the end of each task', while food inspection tables (36.5%), food preparation tables for distribution (31.2%), dish machines (34.2%), overflow and trenches (25.7%), and floors (25.8%) were most often disinfected 'once a day'. All cooking utensils were most often disinfected 'at the end of each task'. 'Chemical disinfection' was most frequently used in all foodservice facilities. To improve the food safety management of foodservice operations, it is necessary to apply the HACCP protocol and comply with the washing and disinfection manual.

Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System (소독부산물 최소화를 위한 운영조건 연구)

  • Shin, Hyung-Soon;Choi, Phil-Kweon;Kim, Jong-Su;Choi, Ill-Woo;Kim, Sang-Hoon;Kim, Tae-Hyun;Lee, Kyung-Hee;Lee, Soo-Moon;Jang, Eun-Ah;Jung, Yeon-Hoon;Kim, Jung-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.

A Study of Disinfection Process Automation through Control Logic Program Development (제어로직 프로그램 개발을 통한 소독공정 자동운전에 관한 연구)

  • Park, Jong-Duk;Shin, Gang-Wook;Hong, Sung-Taek;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3644-3653
    • /
    • 2011
  • This study proposes the automation of disinfection process in water treat plant to reach target effluent chlorine concentration rate according to chlorine consumption rate by varying travel time. Hydraulic analysis about the process and local facility was surveyed first and the program for automatic operation was developed to solve current problem, whose applied result was presented and proved to be better than present controller. Especially using multi variable process algorithm, the correlation coefficient is analyzed between environment factor and reaction time, and process control prove to be stable through model estimation with optimal control input.

Infection Control practices in accordance characteristic of Dental institutions -Daegu and North Gyeongsang Province around- (치과의료기관의 특성에 따른 감염관리실태 -대구, 경북지역을 중심으로-)

  • Sung, Mi-Ae;Yoon, Sung-Uk
    • Journal of Digital Convergence
    • /
    • v.16 no.5
    • /
    • pp.299-307
    • /
    • 2018
  • This study survey research of infection control, wastewater management, and instrument disinfection according to characteristic at Daegu, Gyeongbuk Province In 2012 and 2017, the same 114 dental clinics to identify the infection management behavior and prevent infection of dental medical institutions. Scored mean 3.37 points on 8 items of infection control, 95.5% in "records of the patient's medical history", 1.8% in "presence of a wastewater facility." Scored 94.7% in "disinfection of metal trays", 17.5% in "storage from a spitting receptacle in the waste bin and commissioned management.", Scored higher in of infection control, wastewater management and instrument disinfection according to general characteristics and dental characteristics in 2017 than in 2012. Points were higher dental hygienist, University graduation, Type of duty was counseling and management, hospital or higher, Number of dentist(dental hygienist, chair, patient) was high. Therefore raise a need for infection control into consideration the dental characteristics and education and promotion regardless of the hospital size.

Seasonal Changes of Microbiological Counts and Sanitation State on the Surface of Foodservice Facilities and Utilities (급식시설 . 설비 표면의 위생상태 및 계절별 미생물 균수의 변화)

  • Kim, Ji-Hyun;Kim, Yi-Sun;Han, Ji-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.10
    • /
    • pp.1653-1660
    • /
    • 2004
  • This study was conducted to investigate seasonal changes of microbiological counts and sanitation state on the surface of food service facilities and utilities of elementary schools in Busan area. Samples swabbed using sponge were collected from the surface of food service facilities and utilities, that is ceiling, wall, floor, trench, grease trap, hood, pest control net and dumb waiter, and analyzed by measuring the total plate, coliform and Salmonella spp. count. The total plate counts at foodservice facilities and utilities except ceiling and wall were ranged from 10$^4$∼10$^{6}$ CFU/100 $\textrm{cm}^2$. The coliform counts were ranged from 10$^2$∼10$^4$ CFU/100 $\textrm{cm}^2$ at foodservice facilities and utilities except ceiling. The grease trap was the severely contaminated facility. It was indicated that the sanitary condition at the foodservice facilities and utilities except ceiling and wall should be improved promptly. As a result of investigating the seasonal changes of microbiological counts, floor, trench, grease trap and dumb waiter should be carried out disinfection before foodserving everyday in summer season, and the disinfection frequencies of wall, hood and pest control net should not be less than three times per week. In winter season floor, trench, and dumb waiter should be carried out disinfection after foodserving, grease trap should be carried out disinfection before foodserving everyday and the disinfection frequencies of wall, hood and pest control net should not be less than twice per week.