• Title/Summary/Keyword: Discrete Level measurement

Search Result 18, Processing Time 0.028 seconds

A Computerized Design System of the Axial Fan Considering Performance and Noise Characteristics (성능 및 소음특성을 고려한 축류 팬 설계의 전산 체계)

  • Lee, Chan;Kil, Hyun-Gwon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.2
    • /
    • pp.48-53
    • /
    • 2010
  • A computerized design system of axial fan is developed for constructing 3-D blade geometry and predicting both aerodynamic performance and noise. The aerodynamic blading design of fan is conducted by blade angle distribution, camber line determination, airfoil thickness distribution and blade element stacking along spanwise distance. The internal flow and the aerodynamic performance of designed fan are predicted by the through-flow modeling technique with flow deviation and pressure loss correlations. Based on the predicted internal flow field and performance data, fan noise is predicted by two models for discrete frequency and broadband noise sources. The present predictions of the flow distribution, the performance and the noise level of actual fans are well agreed with measurement results.

Measurement of Willingness to Pay by Using Fuzzy Theory (퍼지이론을 이용한 지불의사액의 추정)

  • Lee, Sung Tae;Lee, Kwangsuck
    • Environmental and Resource Economics Review
    • /
    • v.15 no.5
    • /
    • pp.921-937
    • /
    • 2006
  • In this paper, we apply fuzzy theory in a discrete choice Contingent Valuation Method(CVM) in order for dealing preference uncertainty problem. Fuzzy membership function is used in an empirical analysis to estimate the willingness-to-pay(WTP) for the preservation of the endangered Asiatic Black Bear in Korea. The estimated WTP was about 9,090 Korea Won per household with 78 percent of confidence level. The advantage of applying fuzzy theory in the valuation method could be found in its ability to measure the confidence level of the estimated WTP.

  • PDF

Real-Time Implementation of Power Frequency Estimation Algorithm Based on a Three-Level Discrete Fourier Transform (3레벨 DFT 기반 계통주파수 측정 알고리즘의 실시간 구현에 관한 연구)

  • Moon, JoonHyuck;son, DaeHee;Song, JiHyun;Song, MyeongHoon;Lee, SeungHee;Kang, SangHee;Nam, SoonRyul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.579-580
    • /
    • 2015
  • Power frequency is one of important operational parameters evaluating reliability, stability, and measuring efficiency of power. Therefore, an accurate and fast estimate of the power frequency is required. The magnitude gains of cosine and sine filters become different when the power frequency is deviated from the nominal value. The proposed algorithm estimates the power frequency based on this. To demonstrate the performance of the proposed algorithm, RTDS and DSP are used. The simulation results show that the algorithm has not only a high level of robustness but also high measurement accuracy over a wide range of frequency changes. In addition, the algorithm was immune to harmonics and noise.

  • PDF

Shear Deformation of Steel Fiber-Reinforced Prestressed Concrete Beams

  • Hwang, Jin-Ha;Lee, Deuck Hang;Ju, Hyunjin;Kim, Kang Su;Kang, Thomas H.K.;Pan, Zuanfeng
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.sup3
    • /
    • pp.53-63
    • /
    • 2016
  • Steel fiber-reinforced prestressed concrete (SFRPSC) members typically have high shear strength and deformation capability, compared to conventional prestressed concrete (PSC) members, due to the resistance provided by steel fibers at the crack surface after the onset of diagonal cracking. In this study, shear tests were conducted on the SFRPSC members with the test variables of concrete compressive strength, fiber volume fraction, and prestressing force level. Their localized behavior around the critical shear cracks was measured by a non-contact image-based displacement measurement system, and thus their shear deformation was thoroughly investigated. The tested SFRPSC members showed higher shear strengths as the concrete compressive strength or the level of prestress increased, and their stiffnesses did not change significantly, even after diagonal cracking due to the resistance of steel fibers. As the level of prestress increased, the shear deformation was contributed by the crack opening displacement more than the slip displacement. In addition, the local displacements around the shear crack progressed toward directions that differ from those expected by the principal strain angles that can be typically obtained from the average strains of the concrete element. Thus, this localized deformation characteristics around the shear cracks should be considered when measuring the local deformation of concrete elements near discrete cracks or when calculating the local stresses.

Measurement of Glucose and Protein in Urine Using Absorption Spectroscopy Under the Influence of Other Substances (타 성분 영향을 고려한 요당과 요단백의 흡수분광학 진단)

  • Yoon, Gil-Won;Kim, Hye-Jeong
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.346-353
    • /
    • 2009
  • Glucose and protein in urine are among the important substances for urine analysis and have generally been measured based on a reagent strip test. In this study, these two substances were measured using mid-infrared absorption spectroscopy. Samples were prepared from a commercial synthetic urine product. Glucose and albumin were added as well as red blood cells, which are expected to create the most spectroscopic interference of any substance. Concentrations of these substances were varied independently. Optimal wavelength regions were determined from a partial least squares regression analysis (glucose 980 - 1150/cm, albumin 1400 - 1570/cm). Interference by other substances increased the differences between measured and predicted values. Albumin measurement in particular weres heavily influenced by the presence of glucose and red blood cells. Depending on the inference by other substances, measurement errors were 29.85${\sim}$45.19 mg/dl for a glucose level between 0 and 1000 mg/dl and 14.0${\sim}$93.11 mg/dl for an albumin level of 0 ${\sim}$ 500 mg/dl. Our study proposes an alternative to the chemical test-strip analysis, which shows only discrete concentration levels.

Development of Long Term Flow Duration Curves for the Management of Total Maximum Daily Loads - in the Nakdong River Basin - (수질오염총량관리 단위유역 장기유황곡선 구축 -낙동강수계를 대상으로-)

  • Kim, Gyeong hoon;Kwon, Heon gak;Ahn, Jung min;Kim, Sanghun;Im, Tae hyo;Shin, Dong seok;Jung, Kang-Young
    • Journal of Environmental Science International
    • /
    • v.26 no.8
    • /
    • pp.939-953
    • /
    • 2017
  • For the development of flow duration curves for the management of 41 Total Maximum Daily Load (TMDL) units of the Nakdong River basin, first, an equation for estimating daily flow rates as well as the level of correlation (correlation and determination coefficients) was extrapolated through regression analysis of discrete (Ministry of Environment) and continuous (Ministry of Land, Infrastructure and Transportation) measurement data. The equation derived from the analysis was used to estimate daily flow rates in order to develop flow duration curves for each TMDL unit. By using the equation, the annual flow duration curves and flow curves, for the entire period and for each TMDL unit of the basin, were developed to be demonstrated in this research. Standard flow rates (abundant-, ordinary-, low- and drought flows) for major flow duration periods were calculated based on the annual flow duration curves. Then, the flow rates, based on percentile ranks of exceedance probabilities (5, 25, 50, 75, and 95%), were calculated according to the flow duration curves for the entire period and are suggested in this research. These results can be used for feasibility assessment of the set values of primary and secondary standard flow rates for each river system, which are derived from complicated models. In addition, they will also be useful for the process of implementing TMDL management, including evaluation of the target level of water purity based on load duration curves.

Effective PPG Signal Processing Method for Detecting Emotional Stimulus (감성 자극 판단을 위한 효과적인 PPG 신호 처리 방법)

  • Oh, Dong-Gi;Min, Byung-Seok;Kwon, Sung-Oh;Kim, Hyun-Joong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5C
    • /
    • pp.393-402
    • /
    • 2012
  • In this study, we propose a signal processing algorithm to measure the arousal level of a human subject using a PPG(Photoplethysmography) sensor. From the measured PPG signals, the arousal level is determined by PPI(Pulse to Pulse Interval) and discrete-time signal processing. We ran psychophysical experiments displaying visual stimuli on TV display while measuring PPG signal from a finger, where the nature landscape scenes were used for restorative effect, and the urban environments were used to stimulate the stress. However, the measured PPG signals may include noise due to subject movement and measurement error, which results in incorrect detections. In this paper, to mitigate the noise impact on stimulus detection, we propose a detecting algorithm using digital signal processing methods and statistics of measured signals. A filter is adopted to remove a high frequency noise and adaptively designed taking into account the statistics of the measured PPG signals. Moreover we employ a hysteresis method to reduce the distortion of PPI in decision of emotional. Via experiment, we show that the proposed scheme reduces signal noise and improves stimulus detection.

A-team Based Approach for Reactive Power/Voltage Control Considering Steady State Security Assessment (정태 안전성 평가를 고려한 무효전력 전압제어를 위한 A-team기반 접근법)

  • Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.150-159
    • /
    • 1996
  • In this paper, an A-team(Asynchronous Team ) based approach for Reactive power and volage control considering static security assessment in a power system with infrastructural deficiencies is proposed. Reactive power and voltage control problem is the one of optimally establishing voltage level given several constraints such as reactive generation, voltage magnitude, line flow, and other switchable reactive power sources. It can be formulated as a mixed-integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The security assessment is to estimate the relative robustness of the system in Its present state through the evaluation of data provided by security monitoring. Deterministic approach based on AC load flow calculations is adopted to assess the system security, especially voltage security. A security metric, as a standard of measurement for power system security, producting a set of discrete values rather than binary values, is employed. In order to analyze the above two problems, reactive power/voltage control problem and static security assessment problem, in an integrated fashion for real-time operations, a new organizational structure, called an A-team, is adopted. An A-team is an organization for agents which ale all autonomeus, work in parallel and communicate asynchronously, which is well-suited to the development of computer-based, multi-agent systems for operations. This A-team based approach, although it is still in the beginning stage, also has potential for handling other difficult power system problems.

  • PDF