• 제목/요약/키워드: Discontinuous Current Mode(DCM)

검색결과 71건 처리시간 0.018초

New Isolated Single-Phase AC-DC Converter for Universal Input Voltage

  • Lee, Ming-Rong;Yang, Lung-Sheng;Lin, Chia-Ching
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.592-599
    • /
    • 2013
  • This paper investigates a new isolated single-phase AC-DC converter, which integrates a modified AC-DC buck-boost converter with a DC-DC forward converter. The front semi-stage is operated in discontinuous conduction mode (DCM) to achieve an almost unity power factor and a low total harmonic distortion of the input current. The rear semi-stage is used for step-down voltage conversion and electrical isolation. The front semi-stage uses a coupled inductor with the same winding-turn in the primary and secondary sides, which is charged in series during the switch-on period and is discharged in parallel during the switch-off period. The discharging time can be shortened. In other words, the duty ratio can be extended. This semi-stage can be operated in a larger duty-ratio range than the conventional AC-DC buck-boost converter for DCM operation. Therefore, the proposed converter is suitable for universal input voltage (90~264 $V_{rms}$) and a wide output-power range. Moreover, the voltage stress on the DC-link capacitor is low. Finally, a prototype circuit is implemented to verify the performance of the proposed converter.

전류 불연속 모드로 동작하는 벅 컨버터의 새로운 PWM 제어 방식에 관한 연구 (A Study on the Leading Edge Modulation Buck converter Operating in Discontinuous Conduction Mode)

  • 이재삼;손호인;조훈희
    • 전력전자학회논문지
    • /
    • 제12권3호
    • /
    • pp.241-247
    • /
    • 2007
  • LLC 하프브리지 다중 출력용 컨버터의 보조 출력부와 같이, 펄스 전압을 입력으로 갖는 PWM 컨버터에서는 출력 정전압 제어를 위하여 스위치의 턴 온 제어 방식을 필요로 한다. 본 논문에서는 전류 불연속 모드로 동작하는 벅 컨버터의 새로운 도통시간 턴 온 제어방식에 대하여 논하였다. 제안된 LEM 제어 방식의 PWM 동작 원리를 설명하였으며, 임펄스 응답 이론을 근거로 인덕터 전류의 소신호 주파수 응답 특성을 고찰하였다. 또한 60인치 PDP 어드레스용 100W급 파워 모듈에 적용함으로서 제안된 제어 방식의 타당성을 검증하였다.

고조파 저감을 위한 소프트 스위칭 승압형 PFC컨버터의 특성해석 (Characteristics analysis of PFC boost converter with soft switching for harmonics reduction)

  • 김봉규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.150-154
    • /
    • 2000
  • This paper proposes PFC boost converter with soft switching for harmonics decrement and analyzes characteristics of PFC boost converter. In this technique power factor correction(PFC) is usually obtained by operating the PFC stage in the discontinuous current mode(DCM) Switching devices are operated for reducing current stress and electronical noise. As a result eliminate 3rd harmonic component and high power factor(PF) of the input line are verified by characteristics analysis and experimental results.

  • PDF

Real-Time HIL Simulation of the Discontinuous Conduction Mode in Voltage Source PWM Power Converters

  • Futo, Andras;Kokenyesi, Tamas;Varjasi, Istvan;Suto, Zoltan;Vajk, Istvan;Balogh, Attila;Balazs, Gergely Gyorgy
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1535-1544
    • /
    • 2017
  • Advances in FPGA technology have enabled fast real-time simulation of power converters, filters and loads. FPGA based HIL (Hardware-In-the-Loop) simulators have revolutionized control hardware and software development for power electronics. Common time step sizes in the order of 100ns are sufficient for simulating switching frequency current and voltage ripples. In order to keep the time step as small as possible, ideal switching function models are often used to simulate the phase legs. This often produces inferior results when simulating the discontinuous conduction mode (DCM) and disabled operational states. Therefore, the corresponding measurement and protection units cannot be tested properly. This paper describes a new solution for this problem utilizing a discrete-time PI controller. The PI controller simulates the proper DC and low frequency AC components of the phase leg voltage during disabled operation. It also retains the advantage of fast real-time execution of switch-based models when an accurate simulation of high frequency junction capacitor oscillations is not necessary.

새로운 DCM-ZVS DC-DC 컨버터에 관한 연구 (A Study on New DCM-ZVS DC-DC Converter)

  • 곽동걸;심재선
    • 전기전자학회논문지
    • /
    • 제16권2호
    • /
    • pp.131-137
    • /
    • 2012
  • 본 논문에서는 영전압 스위칭(ZVS)과 전류불연속 모드(DCM)에 의한 새로운 고효율의 DC-DC 컨버터에 대해 연구된다. 일반적으로 고효율의 컨버터를 만들기 위해서는 전력변환기내에 사용된 반도체 스위칭 소자의 손실을 최소화하여 이루어진다. 제안한 컨버터는 DCM에 의하여 스위치의 턴-온 동작을 영전류 스위칭(ZCS)으로 만들고, 또한 새로운 유사공진 회로를 접목하여 컨버터의 고효율을 실현시킨다. 제안한 컨버터에 사용된 제어용 스위칭 소자들은 유사공진 기법에 의해 소프트 스위칭, 즉 ZVS와 ZCS으로 동작시키고, 이에 따른 제어용 스위칭 소자들은 전압과 전류의 스트레스 없이 동작한다. 그 결과 제안한 컨버터는 스위칭 손실의 저감에 의해 고효율로 구동된다. 제안한 DCM-ZVS 컨버터의 소프트 스위칭 동작과 시스템 효율은 디지털 시뮬레이션과 실험결과를 통해 그 타당성이 입증된다.

Analysis, Design and Development of a Single Switch Flyback Buck-Boost AC-DC Converter for Low Power Battery Charging Applications

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.318-327
    • /
    • 2007
  • The design and performance analysis of a power factor corrected (PFC), single-phase, single switch flyback buck-boost ac-dc converter is carried out for low power battery charging applications. The proposed configuration of the flyback buck-boost ac-dc converter consists of only one switch and operates in discontinuous current mode (DCM), resulting in simplicity in design and manufacturing and reduction in input current total harmonic distortion (THD). The design procedure of the flyback buck-boost ac-dc converter is presented for the battery charging application. To verify and investigate the design and performance, a simulation study of the flyback buck-boost converter in DCM is performed using the PSIM6.0 platform. A laboratory prototype of the proposed single switch flyback buck-boost ac-dc converter is developed and test results are presented to validate the design and developed model of the system.

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

고성능 DCM-ZVS 스텝 업-다운 AC-DC 컨버터에 관한 연구 (A Study on Step Up-Down AC-DC Converter with DCM-ZVS of High Performance)

  • 곽동걸
    • 전기전자학회논문지
    • /
    • 제16권4호
    • /
    • pp.335-342
    • /
    • 2012
  • 본 논문에서는 고효율과 고역률을 위한 새로운 DCM-ZVS 스텝 업-다운 AC-DC 컨버터에 대해 연구된다. 제안한 DCM-ZVS 컨버터에 사용된 스위칭 소자들은 새로운 유사공진 회로에 의해 소프트 스위칭 기법으로 동작되고, 펄스폭변조(PWM) 방식에 의한 전류불연속모드(DCM)로 구동된다. 제안한 컨버터의 유사공진 회로는 스텝 업-다운 인덕터와 무손실 스너버 커패시터로 구성되고, 또한 DCM에 의해 제어회로 기법과 제어회로 구성이 간단한 장점이 주어진다. 입력 교류 전류파형은 일정 스위칭 주파수에 의한 교류 입력전압의 크기에 비례한 유사 정현파형으로 된다. 그 결과, 제안한 DCM-ZVS 컨버터는 낮은 스위칭 손실과 고효율을 얻을 수 있으며, 컨버터의 입력역률은 거의 단위역률로 된다. 해석적 결과의 타당성은 다양한 컴퓨터 시뮬레이션과 실험 결과를 통해 입증된다.

Primary Side Regulator의 부하 전류 예측 알고리즘 (Load current prediction algorithm for Primary Side Regulator (PSR))

  • 서동현;금문환;최윤;오동성;한상규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.319-320
    • /
    • 2013
  • 본 논문에서는 PSR(Primary Side Regulator)에 적용 가능한 새로운 방식의 부하 전류 예측 알고리즘을 제안한다. 기존의 부하 전류 예측 방식은 DCM(Discontinuous Conduction Mode) 및 BCM(Boundary Conduction Mode) 동작만이 가능하다. 하지만 제안된 방식은 Power Balance Rule을 적용한 간단한 알고리즘을 통해 CCM(Continuous Conduction Mode) 동작에서도 정확한 부하 전류 예측이 가능하다. 따라서 높은 출력을 요구하는 어플리케이션에서 고효율 달성에 유리하고, CC(Constant Current) 제어가 우수하다. 제안 알고리즘의 우수성과 신뢰성 검증을 위하여 12W급 플라이백 컨버터의 시작품을 제작하였고, 이를 이용한 실험 결과를 바탕으로 타당성을 확인한다.

  • PDF

열가소성 폴리우레탄과 벅-부스트 컨버터를 이용한 마이크로 에너지 포집시스템 설계 (Design of Micro Energy Harvesting System using Thermoplastic Polyurethane and Buck-boost Converter)

  • 손영대;김규현
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.560-565
    • /
    • 2011
  • This paper proposes the design of micro energy harvesting system by using thermoplastic polyurethane(TPU), which harvests electric energy from the kinetic energy of pedestrian and drives the desired load, and applied it to the self-generating shoes. Also, we designed the buck-boost converter in discontinuous conduction mode(DCM) which functions as a resistor emulator(RE) such that converter's average input current is proportional to input voltage, and it results in transfer of maximum power to buck-boost converter according to control behavior that converter's input resistance is matched with TPU's internal resistance. Therefore, this paper confirms the validity of proposed control scheme and possibility of application for self-generating shoes, from the obtained characteristic of designed micro energy harvesting system by using a TPU and buck-boost converter in DCM.