• 제목/요약/키워드: Discharging voltage

검색결과 288건 처리시간 0.026초

산화된풀리에틸렌의 부분방전 특성 (The Partial Discharge Properties of Oxidized Polyethylene)

  • 이현수;한상옥
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.802-808
    • /
    • 1992
  • To investigate degradation procedure and life time of the oxidized PE and the unoxidized PE, alternative voltage is applied to the CIGRE Method-II (CM-II) electrode system, which is loaded artificial void, and measures the distribution of partial discharging generation. From the results, the samples etched by oxidation had wide degradation area of dielectric strength. Furthermore, discharge starting voltage was shifted to low voltage, the discharge generation frequency was high and consequently, the quantity of mean charge becomes small. Also, life time of the oxdized sample is shortened according as the oxidation time is longer.

  • PDF

분포정수회로를 이용한 고전압 급준 펄스 연구 (A Study on the Very Fast Rising High Voltage Pulse Using Distributed Circuit)

  • 곽희로;권동진;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.274-277
    • /
    • 1994
  • This paper describes a very fast rising high voltage pulse generation for studying surge phinomenon and prebreakdown of liquid dielectric by appling the traveling wave theory of the distributed circuit. This very fast rising high voltage pulse generator consists of a charging coaxial cable, a discharging switch, and a terminating resistance. As results, the rising time of pulses are about 31(nsec), which is very fast, and its duration is 950[nsec] when using 200[m] coaxial cable. The length of the coaxial cable and changing voltage can regulate the duration and the amplitude or the polarity of the pulse. When terminated the resistance, capacitor and inductor, the measured waveform corresponds with simulated waveform.

  • PDF

조기방전용 접지판의 개발 및 특성 (Development and Its Characterization of Earth Plate for Early Streamer Discharge)

  • 최상원;허용
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.46-48
    • /
    • 2014
  • This paper compared and demonstrated the performance of the earth plate for conventional type and early streamer discharging type developed a new plate in order to improve the performance of the ground plate for use in grounding. The results obtained are shown below; early streamer discharge earth plate was high 5 kV on DC flashover voltage and corona discharge current was higher than about 2 times under the same test conditions compared to the conventional earth plate. From the experiential result, streamer discharge earth plate had a function of rapid inflow/out flow than the general ground plane because of by corona discharge current to be generated in the sharp serrated in formed the ground plane when strike current occurred. In the future, the newly developed early streamer discharge ground plate would be beneficial for grounding work to be widely used to promote the convenience and economy of construction.

ESS 적용에 따른 도시철도차량의 회생 에너지 이용률 향상 연구 (A Study on Enhancing Regenerative Energy Efficiency for Urban Railway Vehicles by Applying Energy Storage System)

  • 우종혁;한정호;이주
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1306-1311
    • /
    • 2014
  • In this paper, effect of recharging power by using ESS(Energy Storage System) was investigated when ESS was applied to the train. The recharging power was analyzed and measured. Also, by applying ALVT algorithm, effective recharging and discharging were studied. By using this process, recharging and discharging of the super capacitor were improved which led to enhancing the use of recharging power from the urban Railway vehicles.

Analysis and Implementation of a DC-DC Converter for Hybrid Power Supplies Systems

  • Yang, Lung-Sheng;Lin, Chia-Ching
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1438-1445
    • /
    • 2015
  • A new DC-DC power converter is researched for renewable energy and battery hybrid power supplies systems in this paper. At the charging mode, a renewable energy source provides energy to charge a battery via the proposed converter. The operating principle of the proposed converter is the same as the conventional DC-DC buck converter. At the discharging mode, the battery releases its energy to the DC bus via the proposed converter. The proposed converter is a non-isolated high step-up DC-DC converter. The coupled-inductor technique is used to achieve a high step-up voltage gain by adjusting the turns ratio. Moreover, the leakage-inductor energies of the primary and secondary windings can be recycled. Thus, the conversion efficiency can be improved. Therefore, only one power converter is utilized at the charging or discharging modes. Finally, a prototype circuit is implemented to verify the performance of the proposed converter.

MgO Properties Depending on E-beam Evaporation Rate and Its Effects on the PDP Discharging Characteristics

  • Kwon, Sang-Jik;Kim, Yong-Jae;Li, Zhao Hui;Kim, Kwang-Ho;Lee, Dal-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.890-893
    • /
    • 2006
  • Effects of the evaporation rate of MgO films using electron beam were investigated on the MgO properties and the discharge characteristics of the plasma display panel (PDP). The evaporation rate was changed from 3 ${\AA}/sec$ to 15 ${\AA}/sec$ at a substrate temperature of $300\;^{\circ}C$. MgO properties such as crystal orientation, surface roughness, contact angle, and film structure were inspected using XPS, AFM, drop shape analysis and SEM. We also studied the relation between MgO properties and PDP discharging characteristics. The minimum firing voltage and maximum efficacy were obtained at evaporation rate of 5 ${\AA}/sec$. In the MgO film deposited at 5 ${\AA}/sec$, (200) orientation was most intensive and surface roughness was minimum.

  • PDF

금속-산화막-반도체(MOS) 소자에서의 전자주입에 따른 느린 준위의 전류 응답 특성 연구 (The Electron Injection-induced Slow Current Transients in Metal-Oxide-Semiconductor Capacitors)

  • 최성우;전현구;안병철;노관종;노용한
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.216-219
    • /
    • 1999
  • A simple two-terminal cyclic current-voltage(I-V) technique is used to measure the current-transients in MOS capacitors. Distinct charging/discharging currents were measured and analyzed as a function of (1) the hold time. (2) the gate polarity during the FNT electron injection, (3) the injection fluence and (4) the annealing time after the injection had stopped. Discharging and charging current-transients were strongly dependent upon the conditions for forming the inversion layer and the density of interface traps caused during the FNT electron injection, respectively. Several tentative mechanisms were suggested in the current work.

  • PDF

승강기의 비상 통화장치용 비상 전원장치의 충·방전 제어회로 (Control Scheme of Emergency Power Supply for Elevator Emergency Call System)

  • 박노식;이동희
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.40-48
    • /
    • 2015
  • In this paper, battery charging and discharging circuit with a single voltage power supply is proposed. The proposed circuit has the separated current path and charging-monitoring sequence control scheme. In the charging sequence, the proposed 2-level comparator combined with control signal of the micro-processor can control the constant charging current to protect the over current of the battery. Furthermore, the proposed circuit uses a periodic main power switch control to detect the discharging characteristics to estimate the approximated battery life-time. In the experiments, the proposed emergency power supply for emergency call system has 89% efficiency with 98% power factor. And the proposed sequence control scheme is well operated in the designed emergency power system.

제어전극을 갖는 방전소자의 방전개시전압 설계에 관한 연구 (A Study on the Design of Discharge Voltage of Discharge Element with Control Electrode)

  • 박근석;최준웅;이대동
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1512-1516
    • /
    • 2018
  • The power system and control system constantly reveals surge voltage such as switching surge of lighting devices and power conversion devices, operating and stops surge of rotating devices, charge & discharge surge, opening & closing surge of circuit breakers and the like. Such a surge voltages can cause damage or malfunction of the element such as CPU, Memory, semiconductor etc. In the industry, in order to protect the system from the surge voltage, a surge protector with low discharge starting voltage, fast response time, and low capacitance is required, and technical development research for that is ongoing. In this paper, in order to solve the problem of the existing GDT discharge tube not discharging from the transient voltage which is higher than the commercial voltage and lower than the discharge voltage of the discharge element, we have developed a discharge element having the control electrode & control circuit. The discharge element having the control electrode and the control circuit can control the discharge voltage according to the needs of the consumer and can satisfy the requirement of the discharge element and the technology of the surge protector downsizing technology and the surge protection technology. It is judged to be effective for development.

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.