• Title/Summary/Keyword: Discharging Area

Search Result 112, Processing Time 0.028 seconds

A Study on the Change of Current in the Vicinity of Mokpo Harbor and Its Impact on Ship Operation due to the Discharge through Yongsan River Estuary Weir and Yongam-Kumho Sea Dike (영산강 하구둑 및 영암-금호방조제의 방류에 의한 목포항 주변수역의 유동변화 및 선박운용에 미치는 영향에 관한 연구)

  • 정대득;이중우;국승기
    • Journal of Korean Port Research
    • /
    • v.13 no.1
    • /
    • pp.133-146
    • /
    • 1999
  • Mokpo coastal area is connected to the adjacent a long river and two large basins. It is essential for port planning coastal zone management and environmental impact study to analyze the data related to the ship operation and variation of current and water quality due to the development of water area including dredging reclamation and estuary barrage. The Yongsan river estuary weir and Yongam-Kumho basins discharge much of water through water gates for the purpose of flood control and prohibit salt intrusion at the inland fresh water area. To meet this purpose discharge through the gates have been done at the period of maximum water level difference between inner river and sea level. This discharged water may cause the changes of current pattern and other environmental influences in the vicinity and inner area of semi-closed Mokpo harbor. In this study ADI method is applied to the governing equation for the analysis of the changes on current pattern due to discharged water. As the results of this study it is known that the discharging operation causes many changes including the increase of current velocity at the front water area at piers approaching passage and anchorages. Discussion made on the point of problems such as restricted maneuverability and the safety of morred vessels at pier and anchorage. To minimize this influence the linked gate operation discharging warning system and laternative mooring system are recommended.

  • PDF

Effect of Mixed Jet with Primary Nozzle Area Ratio of Ejector on Oxygen Transfer Characteristics (산소 전달 특성에 미치는 이젝터 구동 노즐 면적비에 따른 혼합 분류의 영향)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Journal of ILASS-Korea
    • /
    • v.27 no.3
    • /
    • pp.126-133
    • /
    • 2022
  • The objective of this is to experimentally investigate the effect of mixed jet on the oxygen transfer characteristics with the primary nozzle area ratio of an annular nozzle ejector for the application of a microbial fuel cell. A direct visualization method with a high speed camera system was used to capture the horizontal mixed jet images, and a binarization technique was used to analyze the images. The clean water unsteady state technique was used for the oxygen transfer measurement. The air-water mixed jet discharging into a water tank behaved similar to a buoyancy or horizontal jet with the primary nozzle area ratio. It was found that an optimum primary nozzle area ratio was observed where the oxygen transfer performance reached its maximum value due to the decrease of air volume fraction and the increase of jet length and air bubble dispersion.

On the Planning of Drainage Structures in Irrigation Channels. -Special Emphasis on the Drainage Inverted Siphon- (용수로상의 배수구조물계획에 대하여 -배수잠관을 중심으로-)

  • 김철기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.12 no.4
    • /
    • pp.2078-2083
    • /
    • 1970
  • The purpose of this study is to give the data neccesary for improving the planning of drainage structures, specially inverted siphons, in irrigation channels. With the samples of 15 drainage inlets, one drainage flume, 16 drainage inverted siphons and 6 drainage culverts in the 3 lines of irrigation channel under Chong-Won Irrigation Association, author abtained the following results. 1. It is presumed that design drainage discharge should be determined with some additional reserves, on the basis of the maximum rainfall intensity in local area and the size of drainage area on the topographical map, avoiding the way of eye measure. 2. Location of drainage inlet should be kept away from the place where topography can make lots of wash load, but when unavoidably allowing the inflow into irrigation channel, wash load outlet with even the purpose of drainage, or drainage flume in stead of drainage inlet should be taken account of. 3. It is presumed that drainage flume may be the structure which can perform its function from a structural point of view as far as topography permits. 4. Drainage inverted siphon should be avoided at any place as much as possible; a) In case that location of the siphon would be permitted only at paddy field, drainage area hauing the amount of discharge which requires more than 90cm in diameter could only be allowed. b) In this case, crest elevation of the tank of both inlet and outlet, at least, should not be lower than the surface level of paddy field. c) As far as topography and stratum permit, ratio of depth of outlet tank to head drop should be decreased as much as possible so that discharging efficiency of wash load could increase. d) In case of avoiding the setting of the siphon, irrigation aqueduct, irrigation inverted siphon, or drainage flume should be recommended in accordance with topography. 5. Discharging capability of wash load by drainage culvert appeared to depend hardly upon the diameter of the culvert, but greatly upon the location, specially near village, for there stones and dirts dumped may considerably be piled up. So, a counter plan for that is required.

  • PDF

GIS based Water-pollutant Buffering Zone Management

  • Kim, Kye-Hyun;Yoon, Chun-Joo
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.506-506
    • /
    • 2002
  • S. Korean Government has accelerating its efforts to enhance the quality of the drinking water. The Ministry of Environment has declared the law of securing water-pollutant buffering zone to minimize the inflow of the point and nonpoint sources into the drinking water sources. As a first phase of installing nationa-wide water-pollutant buffering zone, approximately 300km buffering zone has been delineated along the South and North Han river, the major drinking water sources for the capital area of S. Korea, which has the population of more than 12 millions. The buffering zone has the width of 1,000 meter for the special protection area, and 500 meter for the remaining area from both ends of the river. The major works have been done in three stages. Firstly, the boundaries lines of the buffering zone was delineated on the digital topographic maps. Secondly, the maps were overlayed with the cadastral maps to identify individual land parcels, the street address of the major pollutant discharging facilities, and all different types of pollutants including livestocks. Thirdly, the field work has been done as a verification. Once the buffering zone was generated, all the information for the buffering gone were created or imported from other government agencies including official land price, details of the major manufacturing facilities discharging considerable amount of pollutants, major motels and resorts, not to mention of restaurants, etc. Also, major livestock houses were located to identify the path of the pollutant inflow to the drinking water source. Further works need to be continued such as purchasing private lands within the buffering zone and change the land use in the efforts to decrease the pollutant amount and to provide more environmentally friendly space. Also, high resolution satellite imagery should be utilized in the near future as a cost-effective data source to update all the landuse activities within buffering zone.

  • PDF

An Experimental Study for Designing Electrostatic Precipitator: Focused on Collection Efficiency Variation per Area and corona Power

  • Kim, Jong-Ho;Cho, Yong-Kyun;Bong, Choon-Keun;Yun, Joong-Sup;Kim, Shin-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E2
    • /
    • pp.79-84
    • /
    • 2000
  • The Electrostatic Precipitator is one of the most favorable device of particulate control systems because of the relatively higher collection efficiency and easier operation/maintenance. However, it requires very high initial coat especially for discharging electrodes and collecting plates. In dealing with such problems, development of optimum design can be one of the solutions. In this study, a bench-scale electrostatic precipitator was operated in terms of collection area and corona power, and its performances were analyzed focusing on collection efficiency. A result of this study, a more advanced approach for designing cost-effective precipitator by promoting corona power at a minimized collection area was proposed.

  • PDF

A CASE REPORT OF MUCOID RETENTION CYST IN MAXILLARY SINUS. (상악동 점액저유낭종의 일례)

  • Kim Han Pyoung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.3 no.1
    • /
    • pp.47-49
    • /
    • 1973
  • The author have observed mucoid retention cyst in the right maxillary sinus of the patient, 41 years old woman, complained discharging of purulent exudate on the right maxillary molar teeth area, and obtained the following conclusions; 1. The mucoid retention cyst in maxillary sinus casts a faint dome shaped shadow into the radiolucent image of maxillary sinus. 2. The mucoid retention cyst in maxillary sinus may be occured without a history of trauma. 3. Intraoral standard films are also valuable for the interpretation of the lesions in maxillary sinus but only extraoral roentgenograms.

  • PDF

Characteristics of particle mixing and detection of poor fluidization in a fluidized bed ash cooler (유동층 저회냉각기에서의 입자 혼합특성과 비유동 진단)

  • Kim, D.W.;Lee, J.M.;Kim, J.S.;Kim, J.J.
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.231-237
    • /
    • 2005
  • Interruption of good fluidization in a fluidized bed ash cooler(FBAC) for discharging bed materials such as sand or coal ash particles from the CFB combustor is frequently happened because of agglomeration of the particles in the bed. This unstable operation may, in the worst case, result in an unscheduled boiler shut down. In this study, we examined the operation problems of the FBAC of Tonghae CFB boiler and studied and introduced the simple detection and solution techniques with analyzing the mixing property and the occurrence of defluidization in a simulated fluidized bed ash cooler system (0.5m-H x 0.5m-W x 1.0m-L). The bridge of the large particles at the bed surface could be observed, and this caused to form the defluidization area at the entrance of the FBAC. The defluidization was affected not only by airflow rates but also by the particles discharging rates as well as particle size distribution in the FBAC. The local defluidization could be detected by analysis of the accumulated standard deviation error at a given period of time. Also, the regulation of the overall or local airflow rate made clearing up the local defluidization possible.

  • PDF

An Analysis of the Impact of Japan's Contaminated Water Release from Nuclear Power Plant on Korean Consumption of Seafood - Focused on Survey Results (일본의 원전 오염수 방류가 국내 수산물 소비에 미치는 영향 분석 : 설문조사 결과를 중심으로)

  • Yun, Yu-Jin;Kim, Eun-Kyeong
    • The Journal of Fisheries Business Administration
    • /
    • v.53 no.2
    • /
    • pp.58-72
    • /
    • 2022
  • Fishery products play an important role in Korean food culture, and awareness of the safety of fishery products is increasing in the seafood market. Against this backdrop, Japan has announced a plan to release radioactive water to the sea from 2023. In the case of Korea, it is adjacent to the area to be discharged, so there are concerns about securing the safety of marine products. Therefore, it is necessary to analyze the change in perception and impact of marine product consumers due to the discharge of contaminated water and to study appropriate countermeasures when discharging contaminated water from nuclear power plants. In this study, the current status of radioactive contaminated water discharge in Japan was summarized, and a survey was conducted on the change in the consumption perception of marine products according to the discharge of contaminated water to analyze the factors affecting the consumption change of domestic consumers. According to the survey, 85.3% of the respondents said that it will affect the purchase of domestic marine products if Japan starts discharging contaminated water from nuclear power plants. Moreover, 85.5% of the respondents said it will affect the purchase of imported marine products.

Biphasic Electrical Nerve Stimulator for Medical Applications Generating a Wide Range of Pulse Specifications Without Microcontroller

  • Jun Sang Yu;Dong Rim Kim;Su Bin Kang;Jung Suk Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.173-178
    • /
    • 2024
  • We present an improved biphasic electrical nerve stimulator designed to overcome limitations. Traditional electrical nerve stimulators lacking a microcontroller unit (MCU) have restrictions in terms of frequency, pulse duration, and amplitude control, making them insufficient for medical applications requiring a broader range of pulse specifications. To address this, we developed a stimulator with enhanced capabilities. By not using an MCU, the design reduces power consumption and the required area, simplifying the overall design and increasing efficiency. In addition, our approach optimizes oscillator parameters to achieve wide frequency and pulse duration ranges. Specifically, we expanded the frequency range of the stimulator up to from 1 mHz to 100 kHz and the pulse duration up to from 5 ㎲ to 500 s. Improved amplitude control mechanisms were implemented for adjustable and high biphasic amplitudes. Furthermore, we added a balancing circuit to ensure proper discharging for tissue safety when biphasic pulses do not occur. The improved stimulator demonstrated an increase in operational range compared to traditional MCU-less designs, producing consistent biphasic pulses with adjustable amplitude and duration. The balancing circuit effectively managed discharging, reducing the risk of tissue damage and ensuring safety and efficacy.

Effect of Non-Agricultural Facilities on Water Quality and Contamination in Rural Area (농촌용수 수질관리를 위한 비농업시설의 영향 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Kim, Yang-Bin;Woo, Nam-Chil;Nam, Kyoung-Phile;Lee, Jong-Min
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • This study was objected to identify the effect on water quality and contamination by non-agricultural facilities in 'A' reservoir watershed located in OO city, Kyounggi-do, Korea. Ground- and stream water samples showed (Na+K)-Cl, Ca(Cl, SO$_4$) and Ca-Cl type in an illegally discharging area of sewage and a densely industrial area indicating water contamination. Stream water of an illegally discharging area of sewage had high COD, T-N and T-P. In this area, direct incoming of sewage into stream water was induced ground water system by well pumping, and it made a progress of ground water contaminations with those components. Groundwater of a densely industrial area showed high concentrations of T-N, NO$_3$N. From a nitrogen isotope analysis, stream water of an illegally discharging area of sewage has ${\delta}^{15}N-NO_3$values of 0.7%0 was strongly affected by nitrogen originated from agrochemicals, and a densely industrial area of 19.7%0 from septic system. Ground- and stream water of a livestock fanning area were contaminated with NH$_3$-N and Mn, which was affected by intensive livestock facilities. SAR-conductivity plot indicates the water does not pose either alkalinity or salinity hazard for irrigation. COD, T-N, T-P, NO$3$-N, NH$_3$N and Mn concentrations from contaminated areas were diminished by mixing with 'A' reservoir water. There were no water contaminations in silver towns, vacationlands around reservoir and golf links. Consequently, it should be made a plan of systematic managements for past and- present possible contaminants and sewage systems in preventing water contamination by non-agricultural facilities.