• 제목/요약/키워드: Discharge.charge-time

검색결과 241건 처리시간 0.035초

AC PDP의 addressing 기간중의 벽전하 분포에 관한 연구 (Wall Charge Distribution In the Address Period of AC Plasma Display Panel)

  • 이기범;김동현;강동식;박정후;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1830-1833
    • /
    • 2000
  • The relationships between driving voltage and the wall charge distribution in the address period of surface discharge type AC Plasma Display Panel have been investigated. The quantity of wall charge on each electrode are detected simultaneously from the electrode current after applying only one addressing discharge pulse. The wall charge Qy on the scan electrode Y is nearly the sum of Qx on the address electrode X and Qz on the sustain electrode 2. The Qy increased with the driving voltage regardless of the kind of electrode, whereas the address time Td decreased, Qz and Qy are increased considerably with the blocking voltage Vz, whereas Qx is decreased. The increase rate of Qx, Qy and Qz for increase in Vz was $-13{\times}10^{-2}$(pc/Vz), and $60{\times}10^{-2}$(pc/Vz) and $70{\times}10^{-2}$(pc/Vz), respectively.

  • PDF

소형 HTS SMES와 실시간 전력계통 시뮬레이터의 연계 알고리즘 제안 (Connection Algorithm Proposal of Real Time Digital Simulator with Miniaturized HTS SMES)

  • 김아롱;김경훈;김광민;박민원;유인근;심기덕;김석호;성기철;박영일
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.96-101
    • /
    • 2010
  • Superconducting Magnetic Energy Storage (SMES) system is one of the key technologies to overcome the voltage sag, swell, interruption and frequency fluctuation by fast response speed of current charge and discharge. In order to evaluate the characteristics of over mega joule class grid connected High Temperature Superconducting (HTS) SMES system, the authors proposed an algorithm by which the SMES coil could be connected to the Real Time Digital Simulator (RTDS). Using the proposed algorithm, users can perform the simulation of voltage sag and frequency stabilization with a real SMES coil in real time and easily change the capacity of SMES system as much as they need. To demonstrate the algorithm, real charge and discharge circuit and active load were manufactured and experimented. The results show that the current from real system was well amplified and applied to the current source of simulation circuit in real time.

전력품질 개선을 위한 초전도 에너지 저장장치와 실시간 전력계통 시뮬레이터의 연계 알고리즘 개발 (Connection algorithm of Real Time Digital Simulator with HTS SMES for power quality improvement)

  • 김아롱;김대원;김경훈;김진근;박민원;유인근;심기덕;김석호;성기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.601_602
    • /
    • 2009
  • Superconducting Magnetic Energy Storage (SMES) system is one of the key technologies to overcome the voltage sag, swell, interruption and frequency fluctuation by fast response speed of current charge and discharge. In order to evaluate the characteristics of over mega joule class grid connected High Temperature Superconducting (HTS) SMES system, the authors proposed an algorithm by which the SMES coil could be connected to the Real Time Digital Simulator (RTDS). Using the proposed algorithm, users can perform the simulation of voltage sag and frequency stabilization with a real SMES coil in real time and easily change the capacity of SMES system as much as they need. To demonstrate the algorithm, real charge and discharge circuit and active load were manufactured and experimented. The results show that the current from real system was well amplified and applied to the current source of simulation circuit in real time.

  • PDF

정극 활물질 $LiMnO_2$의 전기 화학적 특성 (Electrochemical Property of Positive Active Material $LiMnO_2$)

  • 위성동;김종욱;김민성;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.803-806
    • /
    • 2003
  • The impedance of the positive active material $LiMnO_2$ is measured by the changeable trend following the time. The charge capacities of single cell and each cells of four made with thin film prepared in the dry box are measured after measuring the impedance with the interval of 0, 24, 48 and 72 hours. In result, the impedance through the delaying time is not enhanced continuously as result of the time. The variation of capacity enhanced is not watched as the result of the delaying time that all together of the positive thin film and the reference is soaked in the solution of electrolyte of 1M PC $LiClO_4$. But it can be known to increase the discharge capacities as that the impeditive value is decrease.

  • PDF

부분방전에 의한 주계전기의 절연성능 평가 (Insulation Performance Estimation of Main Relays by Partial Discharges)

  • 길경석;김일권;박대원;송재용;이강원;조은제
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

제어전극을 갖는 방전소자의 방전개시전압 설계에 관한 연구 (A Study on the Design of Discharge Voltage of Discharge Element with Control Electrode)

  • 박근석;최준웅;이대동
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1512-1516
    • /
    • 2018
  • The power system and control system constantly reveals surge voltage such as switching surge of lighting devices and power conversion devices, operating and stops surge of rotating devices, charge & discharge surge, opening & closing surge of circuit breakers and the like. Such a surge voltages can cause damage or malfunction of the element such as CPU, Memory, semiconductor etc. In the industry, in order to protect the system from the surge voltage, a surge protector with low discharge starting voltage, fast response time, and low capacitance is required, and technical development research for that is ongoing. In this paper, in order to solve the problem of the existing GDT discharge tube not discharging from the transient voltage which is higher than the commercial voltage and lower than the discharge voltage of the discharge element, we have developed a discharge element having the control electrode & control circuit. The discharge element having the control electrode and the control circuit can control the discharge voltage according to the needs of the consumer and can satisfy the requirement of the discharge element and the technology of the surge protector downsizing technology and the surge protection technology. It is judged to be effective for development.

초고압 $SF_6$가스중의 선구방전기구 (Precursor Discharge Mechanism under EHV in $SF_6$ Gas)

  • 이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1807-1809
    • /
    • 1996
  • The axial discharge at switching operations of EHV $SF_6$ disconnector can lead to the breakdown to the enclosure. Precursor in periphery zone leads to formation of leader over some time delay. Injected charge value depends on electric field and gap geometry. The calculation method for parameters of $SF_6$ insulation for DS in EHV-GIS is suggested by using the new criterion of leader inception in connection with periphery field nearby the boundary of streamer zone.

  • PDF

바 형태 정전기제거장치의 정전기제거성능 향상을 위한 연구 (2) (A Study on Improvement of the Performance of Pulsed AC Ion Bar (2))

  • 이동훈;최동수;김상민;박진철
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.40-45
    • /
    • 2014
  • In display such as LCD, LED, and AMOLED or semiconductor related industries are required to have static ionizer in order to produce reliable goods. The most general type of ionization is called, "corona discharge" that has a slight chances to generate unequal and unstable amount of each +/- ion to the target object. Then, the ionization performance will drastically decrease and end up with quality deterioration problem. continually "A study on the improvement of the performance of pulsed AC ion bar(1)", we have studied consecutive study to improve the current issue via appling "partition wall" at air nozzle surrounding. The results were that the charge decay time and the ion balance was maintained the satisfied range that was within 5 second and ${\pm}50$ V for a 180 days period of time. In additions, the contamination status on the electrode surface was investigated for a 180 days. The little particles was deposited on the electrode surface.

표시기간 중첩 프라이밍 구동기술에 의한 플라즈마 디스플레이 패널의 고속구동특성 (High-Speed Characteristics of Plasma Display Panel using Priming Overlapping with Display Drive Method)

  • 염정덕
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.2004-2009
    • /
    • 2007
  • A new high-speed drive method for the plasma display panel is proposed. In this method, the address period is inserted for the rest period of the sustain pulses and the priming pulse is applied on the entire panel at the same time overlapping with the sustain period. The ramp shaped priming pulse can be made with a simple drive circuit in this technology and the stable sustain discharge can be induced even by a narrow scan pulse in help of the space charge generated from the address discharge. From the experiments, it is ascertained that the priming pulse hardly influences the sustain discharge. Moreover, the voltage margin of the sustain discharge is almost constant though that of the address discharge broadens with narrowing the scan pulse width. And, if the time interval between the scan pulse and the sustain pulse is within $6{\mu}s$, the voltage margin of the address and the sustain discharges are unaffected though the applied position of the scan pulse is changed. High-speed driving with the address pulse of $0.7{\mu}s$ width was achieved and the address voltage margin of 20V and the sustain voltage margin of 10V were obtained.

EDLC의 특성을 고려한 동적전압보상시스템의 개발 (Development of Dynamic Voltage Restorer System Considering Characteristics of EDLC)

  • 이상철;서일동
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.288-292
    • /
    • 2010
  • Recently, in energy storage system, the EDLC is paid attention as a new environmentally friendly energy storage element. This capacitor has higher energy density than the electrolytic capacitor. Also, this capacitor has a lot of advantage such as no maintenance, longer life cycle and faster charge-discharge time than the battery system. But the EDLC must have a each charge-discharge controller to effectively control, an energy design method circuit to use effectively energy, and several compensation techniques to control a optimal operating. In this respect, this study suggests major parameters to effectively represent the characteristics of EDLC, the measurement methods of those parameters have been investigated with experiments, and the interpretation about the buck/boost DC/DC converter for the operation of EDLC.