• Title/Summary/Keyword: Discharge voltage characteristics

Search Result 965, Processing Time 0.023 seconds

The Analysis of Discharge Distribution due to the Inner Void of Extra High Voltage Cable

  • Kim Tag-Yong;Hong Jin-Woong
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.4
    • /
    • pp.155-160
    • /
    • 2005
  • This paper addresses the discharge characteristics of cross-linked polyethylene according to void by the Weibull function. It analyzes discharge number and amount of discharge using Weibull distribution to identify the inter-relationship between partial discharge and defect. We detected a 10 second discharge. The applied voltage increased by 1 [kV] at discharge inception voltage. As a result, in a no-void specimen, the shape parameter was consistent according to the increase of voltage, whereas, in a void specimen, it increased according to the increase of voltage. As the result, the shape parameter expressed a fixed value at no-void specimen. However, in void specimen, according to increasing voltage shape parameter rapidly increases.

Evaluation of Discharge Characteristics Followed by the Development of Blumlein Pulsed Power Source (Blumlein 펄스파워 전원개발 및 방전특성 평가)

  • Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.99-105
    • /
    • 2010
  • This paper discussed the theoretical simulation results for developing the blumlein pulsed power source and showed the circuit configuration and the discharge characteristics of the realistic manufactured pulsed power system. In the simulation, the output voltage characteristics at a load resistor showed the general impulse shape when the impedance of a single coaxial cable is matched with the that of a load resistor. In addition, it is confirmed that output values of the pulsed power can be easily controlled by the duplication of coaxial cables and the pulsed waveform showed the general impulse characteristics. Specifically, the inception discharge voltage in the gap distance of 5[mm] between needle and plane electrodes is about 20[kV] and which is lower than about 29[kV] in 9[mm] due to the difference of the reaching time of the inception voltage. Therefore, this paper showed that the output voltage of the blumlein pulsed power source can be easily controlled.

Size Effects of the Catalyst on Characteristics of Zn/Air Batteries (MnO2입자 크기에 따른 아연공기전지의 특성연구)

  • 김지훈;엄승욱;문성인;윤문수;김주용;박정식;박정후
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1150-1154
    • /
    • 2003
  • The voltage profile during discharge of the zinc air battery has very flat pattern until reach to end of discharge voltage. But, when zinc air battery is discharged by high current, the discharge voltage and energy becomes low. Therefore, we focused on effects of catalyst size to solve this problems by increasing active sites of oxygen reduction reaction. The size of catalyst was reduced from 27 to l${\mu}{\textrm}{m}$ and we examined average discharge voltage, capacity, energy, resistance and characteristics during GSM pulse discharge of zinc air battery with change of current density. And we also measured porosity of the cathode according to the ASTM. So we have got improvement of average discharge voltage and energy when catalyst was minimized and we have got optimum size of catalyst at 5${\mu}{\textrm}{m}$.

Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor (고압전동기 고정자권선의 부분방전 특징추출)

  • Park, Jae-Jun;Kim, Hee-Dong;Lee, Dong-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.112-116
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet transform coefficients.

  • PDF

Discharge Characteristics of a KSTAR NBI Ion Source

  • Chang Doo-Hee;Oh Byung-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.226-233
    • /
    • 2003
  • The discharge characteristics of a prototype ion source was investigated, which was developed and upgraded for the NBI (Neutral Beam Injection) heating system of KSTAR (Korea Superconducting Tokamak Advanced Research). The ion source was designed for the arc discharge of magnetic bucket chamber with multi-pole cusp fields. The ion source was discharged by the emission-limited mode with the control of filament heating voltage. The maximum ion density was 4 times larger than the previous discharge controlled by a space-charge-limited mode with fully heated filament. The plasma (ion) density and arc current were proportional to the filament voltage, but the discharge efficiency was inversely proportional to the operating pressure of hydrogen gas. The maximum ion density and arc current were obtained with constant arc voltage ($80{\sim}100V$), as $8{\times}10^{11}cm^{-3}$ and 1200 A, respectively. The estimated maximum beam current was about 35 A, extracted by the accelerating voltage of 80kV.

The Characteristics of Glow Discharge Plasma Diagnosis (글로우 방전 플라즈마 진단 특성)

  • Woo, Sung-Hun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.372-375
    • /
    • 2009
  • We have studied on plasma diagnosis, characteristics of the glow discharge at the several different conditions of pressure, discharge current and such. The discharge onset voltage and onset current decreased as pressure increase, the general trend was nearly in agreement with the left regions of Paschen's curve. As normal glow discharge, discharge voltage was constant according to discharge current.

  • PDF

The Characteristics of Superposed Ozonizer using Three-Phase Voltage (3상전압을 이용한 중첩방전형 오존발생기의 특성)

  • Kim, Yeong-Hun;Chun, Byung-Joon;Song, Hyun-Jig;Youn, Young-Dae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2259-2261
    • /
    • 1999
  • In this paper, an ozonizer, which can generate individual and superposed silent discharge, using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode) and 2 gaps(gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the quantity of supplied gas($O_2$). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum values was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF

A Study on Degradation Properties of Silicone Cable due to Partial Discharge (부분 방전에 의한 실리콘 케이블의 열화 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.34-39
    • /
    • 2015
  • In this study, the characteristics of partial discharge was measured for the four core silicone cable (0.6/1.0 kV, $1.0SQ{\times}4C$) with insulated part of 15 cm and conductor of 1cm. The following results have been confirmed as a result of this study. When the first line of cable is connected to the positive electrode and the second, third line of cable is connected to the negative electrode, it found that the inception voltage and extinction voltage decreased with increasing the line of negative electrode, and the partial discharge charge quantity(Q) increases, while the number of discharge occurrence has decreased. The inception voltage and extinction voltage of partial discharge has decreased with increasing the degradation rate in the 33%, 67%, 100%. Also, it confirmed that the partial discharge charge quantity(Q) and the number of discharge occurrence has decreased.

Effects of Phosphor Layer Morphology on Discharge Characteristics of Red, Green, and Blue Cells in AC-PDP

  • Lee, Jae-Jin;Jang, Sang-Hun;Tae, Heung-Sik;Choi, Kyung-Cheol
    • Journal of Information Display
    • /
    • v.2 no.4
    • /
    • pp.52-56
    • /
    • 2001
  • This paper presents the effects of the phosphor layer morphology related to the discharge volume on the discharge and radiation characteristics of the Red, Green, and Blue cells in an AC-PDP. As the thickness of the phosphor layer increases and the corresponding discharge volume in the cells decreases, the voltage margin decreases due to an increase in the sustain voltage. In contrast, the IR(Infrared) emission, discharge current, and luminance characteristics remain almost unchanged, regardless of any changes in the phosphor layer morphology.

  • PDF

A Study on Properties of Partial Discharge in Silicone Rubber (실리콘 고무의 부분방전 특성에 관한 연구)

  • Lee, Sung-Ill;Kwon, Young-Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.11
    • /
    • pp.890-894
    • /
    • 2011
  • In this thesis, the silicone filler with a sample size of 0~75 phr and void size of 2~4.5 mm is prepared in order to diagnose the defect of void which exists in widely used insulation material, silicone rubber. In this silicone rubber sample, electrodes are connected and whilst the voltage changes, applied voltage 7 kV~9 kV is increased constantly over time and discharge quantity, discharge frequency and applied voltage (T-QNV) were measured. The discharge quantity of the applied voltage (VQ) is measured to estimate inception voltage and extinction voltage. In addition, under the condition of maintaining constant applied voltage, discharge quantity and discharge frequency (QN) are measured, and its characteristics are analyzed.