• Title/Summary/Keyword: Discharge tester

Search Result 44, Processing Time 0.023 seconds

A Study on the Battery Management System for the optimum conditions of the battery in UPS (UPS용 배터리 최적화를 위한 배터리관리시스템에 관한 연구)

  • Moon, Jong-Hyun;Seo, Cheol-Sik;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.321-324
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system controls the over and under currents of battery for protecting and it was applied algorithm for optimum conditions to estimate the State Of Charge(SOC) in charge or discharge mode. It approved the performance and the algorithm for the estimation of SOC, through the experiments which using the charge and discharge tester and the field tests.

  • PDF

A Indication Functional Inspection circuit development for Fluorescent ramp end of life (EOL) (형광램프 수명말기 표시기능 검측회로 개발)

  • Hong, Sa-Keun;Choi, Hong-Kyoo;Lee, Guen-Moo;Yoon, Cheol-Gu;Choi, Dae-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.7-11
    • /
    • 2008
  • The fluorescent lamp is one of a discharge lane that is used by electric discharge to transfer from electrical energy to light The fluorescent lamp needs a ballast stabilizer when turn it on because it has negative resistance. Characters of electric discharge and transformed characters of ballast stabilizer are connected closely. Therefore, bring out best design directive that consider economical efficiency and term of a application is very important for both characters matching. In this case, we will team to develop tester and functions for expression for recognizing the end of fluorescent lamp life to solve fire problem and losing efficiency of light when a fluorescent lamp goes the end of the expected its life span.

  • PDF

Development of active discharge tester for high capacity lithium-ion battery (대용량 리튬 이온 배터리용 Active 방전시험기의 개발)

  • Park, Joon-Hyung;Yunana, Gani Dogara;Park, Chan Won
    • Journal of Industrial Technology
    • /
    • v.40 no.1
    • /
    • pp.13-18
    • /
    • 2020
  • Lithium-ion batteries have a small volume, light weight and high energy density, maximizing the utilization of mobile devices. It is widely used for various purposes such as electric bicycles and scooters (e-Mobility), mass energy storage (ESS), and electric and hybrid vehicles. To date, lithium-ion batteries have grown to focus on increasing energy density and reducing production costs in line with the required capacity. However, the research and development level of lithium-ion batteries seems to have reached the limit in terms of energy density. In addition, the charging time is an important factor for using lithium-ion batteries. Therefore, it was urgent to develop a high-speed charger to shorten the charging time. In this thesis, a discharger was fabricated to evaluate the capacity and characteristics of Li-ion battery pack which can be used for e-mobility. To achieve this, a smart discharger is designed with a combination of active load, current sensor, and temperature sensor. To carry out this thesis, an active load switching using sensor control circuit, signal processing circuit, and FET was designed and manufactured as hardware with the characteristics of active discharger. And as software for controlling the hardware of the active discharger, a Raspberry Pi control device and a touch screen program were designed. The developed discharger is designed to change the 600W capacity battery in the form of active load.

Frequency-Time Analysis(Partition-FFT) for Tracking Detection (트래킹 검출을 위한 주파수-시간 분석(분할-FFT))

  • Jee S. W.;Lee S. H.;Kim Ch. N.;Lee C. H.;Lee K. S.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.530-538
    • /
    • 2004
  • A electromagnetic waves are used for sensing in insulation diagnosis at electric machine or equipment. When it a method, waves are transformed into the FFT(Fast Fourier Transform); a kind of the process for data transformation. In a general way, a scientist use frequncy band 30[㎒]~l[㎓] to applied field. If we are measured high frequency band, we will need to a high capacity hardware. Also a antenna has a fault on atmospheric phenomena, outside environment and the like. In this paper We proposed new method for detecting electric equipment faulty state using only electric voltage which is generally measured in the electric and electronic field. It is called the Partition-FFT The analytic method is this first divide measured voltage waves into equal parts, second each deal with give effect to the FFT, finally each results deal with a graphic method and gather graphic. We are compare Partition-FFT with discharge form by tracking tester. As the result it demonstrated that the Partition-FFT is applicable.

A study on wear with diacharge valve materials in linear compressor (Linear compressor 토출밸브의 재질에 따른 마멸 특성에 관한 연구)

  • Park, Young-Do;Gu, Su-Hak;Kim, Jung-Hae;Park, Jin-Sung;Lee, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.899-903
    • /
    • 2009
  • Recently, research and development of the linear compressor are being active. The reason is that the one has not only higher efficiency than reciprocating type, but also lower noise. But because the dicharge valve of linear compressor is operated in high pressure and temperature circumstance, it is important to prevent leakeage. In this paper three other plastic reinforced composite materials were used. Those are TPI, PEEK and PEK which were containing other volume and kind of carbon fibers. First, for assessing mechanical properties, we measured the hardness and the heating property of the trst sepecimen by the microvickers hardness tester and the differential scanning calorimeter respectively. Finally, through FALEX tester, we could know the characteristics of the wear proving the results of before-conducted experiments.

  • PDF

Characteristics of Boronized 316L Austenitic Stainless Steel by Powder Boronizing (분말붕소법을 이용한 오스테나이트계 스테인리스 316L강의 기계적 특성 향상을 위한 연구)

  • Cha, Byung-Chul;Bang, Hyun-Bae;Jo, Hyung-Ho;Jung, Uoo-Chang
    • Journal of Surface Science and Engineering
    • /
    • v.44 no.2
    • /
    • pp.55-59
    • /
    • 2011
  • In this study, the mechanical properties of boronized 316L austenitic stainless steel have been investigated. Boronizing was carried out in solid medium consisting of Ekabor powder at $900^{\circ}C$ and $1000^{\circ}C$ for 2, 4 and 8 hours, respectively. The properties of sample were analyzed by field emission scanning electron microscope, X-ray diffractometer, Glow discharge spectrometer, micro-hardness tester and ball-on-disk wear tester. Increasing the boronizing time and temperature, the hardness of boronized samples were shown over Hv 2000 and the thickness of boride layers were also increased linearly. XRD patterns of samples were revealed the presence of borides such as FeB, $Fe_2B$, CrB, $Cr_2B$ and $Ni_3B$. Friction coefficient of boronized STS 316L was shown the low value at $900^{\circ}C$ for 8 hours and $1000^{\circ}C$ for 4 hours, respectively.

Effect of Ambient Temperature on Insulation Lifetime of Inverter Surge Resistant Enameled Wire Prepared with Organic/Inorganic Hybrid Nanocomposite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.3
    • /
    • pp.163-167
    • /
    • 2016
  • Inverter surge resistant enameled wire was prepared with an organic/inorganic hybrid nanocomposite, and the effect of ambient temperature on the insulation lifetime of the enameled wire in the form of twisted pair was studied by a withstanding voltage tester. The organic polymer was Polyesterimide-polyamideimide (EI/AI) and the inorganic material was a Nano-sized silica (average particle size : 15 nm). The enamel thickness was 50 μm and the ambient temperature was 100, 150, 200, and 250, respectively. Transmission electron microscopy (TEM) observation showed that Nano-sized Silica were evenly dispersed in EI/AI. There were many air gaps in a twisted pair, therefore, when voltage was applied to the twisted pair, enamel erosion took place in the air gap area because of partial discharge accordi, ng to Paschen’s law. As ambient temperature increased, insulation lifetime decreased according to Arrhenius relationship, which was explained by the increasing mobility of polymer chains in EI or AI. And insulation breakdown voltage value at 10 kHz was 1,864.5 sec (31.1 min), which is 1.9 times higher than at 20 kHz, 981.6 sec (16.4 min).

The Battery Management System for UPS Lead-Acid Battery (UPS용 납축전지를 위한 배터리관리시스템)

  • Seo, Cheol-Sik;Moon, Jong-Hyun;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.127-133
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system control the currents and voltages of battery for optimum conditions to estimate the State Of Charge(SOC) in charge or discharge mode. It proved the performance and the algorithm for the estimation of SOC, through the experiments which using the charge and discharge tester and the field tests.

Study of the Optimization and the Depth Profile Using a Flat Type Ion Source in Glow Discharge Mass Spectrometry

  • Woo Jin Chun;Kim, Hyo Jin;Lim Heoung Bin;Moon Dae Won;Lee Kwang Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.6
    • /
    • pp.620-624
    • /
    • 1992
  • The analytical performance of glow discharge mass spectrometer (GD-MS), using a flat type ion source is discussed. The efficiency of ion extraction was maximized at the distance between anode and cathode of 6 mm. At the operation condition of 4 mA, -1000 volt, and 1 mbar for the source, the optimum voltages for sampler and skimmer were40 volt and -280 volt, respectively. The intensities of Cu, Zn, and Mn were increased as a function of square root of current approximately. Korea standard reference materials (KSRM) were tested for an application study. The detection limits of most elements were obtained in the range of several ppm at the optimized operating condition. The peaks of aluminum and chromium were interfered by those of residual gases. The depth profile of nickel coated copper specimens (3, 5, 10 ${\mu}m$ thickness) were obtained by plotting time versus intensities of Ni and Cr after checking the thickness of nickel coated using a scanning electron microscope (SEM). At this moment, the sputtering rate of 0.2 ${\mu}m/min$ at the optimum operating condition was determined from the slope of the plot of time to the coating thickness. The roughness spectra of specimen's crater after 16 min, discharge were obtained using a Talysuf5m-120 roughness tester as well.

Surface treatments of environmentally friendly Cr-free organic compounds for corrosion protection of metals (금속의 내식성 향상을 위한 환경 친화형 무크롬 유기화합물의 표면처리)

  • 이원기;박찬영
    • Journal of Environmental Science International
    • /
    • v.12 no.7
    • /
    • pp.801-807
    • /
    • 2003
  • This work aims the search of environmentally friendly pre-treatment technologies to develop chromate replacements for metal finishing industries due to its toxicological properties. Since the corrosion resistance of steel was strongly related to water permeation, galvanized steel sheets were treated with various hydrophobic silane compounds and water-suspended polymer solution. Also, plasma gas discharge was applied to modify the surface of a polymer coated-steel sheet to be hydrophobic. The surface hydrophobicity of materials was introduced by CF$_3$H plasma exposure. The corrosion property before and after the plasma treatment was investigated in a slat spray tester with 3.5 wt.% NaCl at 35$^{\circ}C$. The results showed that both silane/polymer double coatings and plasma treatment of the galvanized steel exhibited significant retardation of corrosion.