• Title/Summary/Keyword: Discharge power

Search Result 2,195, Processing Time 0.025 seconds

A Comparison of Minilaparotomy and Laparoscopic Sterilization (Minilaparotomy 불임술(不妊術)과 복강경불임술(腹腔鏡不妊術)에 관(關)한 비교연구(比較硏究))

  • Bai, Byoung-Choo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.4 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • Anderson(1937), Power and Barnes(1941) reported a study concerning a method of tubal sterilization in association with peritoneoscopy or laparoscopy in which they cauterized the tubes. There appears to have been a hiatus of interest in sterilization (cold or hot) associated with laparoscopy until reintroduction by Palmer(1963), Frangenheim(1964) and Steptoe(1967). On the other hand, for interval female sterilization, however, minilaparotomy is relatively new. By Saunder and Munsick(1972), John Lyle(1974), Frank Stubb(1974), Vitoon(1973) and B.C. Bai(1975), their own technique for interval female sterilization requires 2.0 to 2.5cm, incision at the margin of the mons pubis. In Korea, female sterilization by means of minilaparotomy firstly reported by B.C. Bai using Bai's uterine elevator, of his own device, early in 1975. Recently inteval female sterilization by laparoscopy and minilaparotomy are widely accepted throughout the world especially in Asian countries. Minilaparotomy is carried out from 1974, laparoscopic sterilization from 1976, and in this study each of 250 cases of those were analysed and discussed for the comparison at Seoul Red Cross Hospital. (1) In the age distribution, numerous clients were in their age of $31{\sim}35$ in laparoscopy as well as minilaparotomy. Average 33.7 years in L and 33.2 years in M. (M=minilaparotomy, L=laparoscopic sterilization) (2) As regarding living children, women having 3 children represented the greatest number, 113 cases out of 250 in M group and 102 cases out of 250 in L group. Average No. of child are 2.9 in Land 3.1 in M. (3) Concidering the operation day in the menstrml cycle, the greatest number of cases, those who underwent tubal sterilization during the days of $26{\sim}$, next during the $6{\sim}10$ days of the cycle in both group. (4) Concidering the operation time, 188 cases by laparoscopy were performed in $6{\sim}10$ minutes, 33 cases within 5 minutes and 24 cases in $11{\sim}15$ minutes. Maximum 50 minutes, minimum 4 minutes and average 8.3 minutes. The majority of cases (154 cases) by minilaparotomy required $6{\sim}10$ minutes and 67 cases $11{\sim}15$ minutes, 6 cases within 5 minutes. Maximum 30 minutes, minimum 4 minutes and average 10.4, minutes. In both groups, most of the reasons for the extra length were surgical difficulties such as thick abdominal wall, pelvic adhesion, less cooperation of patients in early period of this study. (5) Hospital stay after operation in L group required $3{\sim}4$ hours in 125 cases, $2{\sim}3$ hours in 41 cases, $4{\sim}5$ hours in 32 cases out of 250. Maximum 8 hours, minimum 1 hour and average 3.8 hours. In M group hospital stay required $6{\sim}7$ hours in 100 cases, over 7 hours in 85 cases, $5{\sim}6$ hours in 46 cases and so on. Maximum 14 hours, minimum 2 hours and average 6.5 hours. (6) The time between operation and gas passing in the majority cases of both groups, were $12{\sim}36$ hours. A veragetime 20.3 hours in L and 27.2 in M. (7) Laparoscopic sterilization coincident with induced abortion were carried out in 27 cases, laparoscopy with minilaparotomy to control for mesosalpingeal hemorrhage in 1 case. Minilaparotomy coincident with induced abortion were performed in 65 cases, D and C whit polypectomy, menstrual regulatian, and remaval of IUD in 1 case respectively. (8) In L group, 1 case of mesosalpingeal hemorrhage, 1 case of abdominal wall infection were complicated during operation. In M group, 1 case of uterine perfaration, 1 case of abdominal wall infection, 1 case of hemorrhage from omentum and 1 case of bloody vaginal discharge were complicated. No intensive medical treatment was required for those minor complications in both groups. (9) No failure has been recognized and these two sterilization techniques might be the simple, safe and the most effective method for permanent contraception at present time. There is no significant clinical defference between L and M group in this study.

  • PDF

Recovery of $SF_6$ gas from Gaseous Mixture ($SF_6/N_2/O_2/CF_4$) through Polymeric Membranes (고분자 분리막을 이용한 혼합가스($SF_6/N_2/O_2/CF_4$)로부터 $SF_6$의 회수)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Choi, Ho-Sang;Lee, Sang-Hyup
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • During the maintenance, repair and replacement process of circuit breaker, $SF_6$ reacted with input air in arc discharge, which led to the production of by-product gases (eg, $N_2$, $O_2$, $CF_4$, $SO_2$, $H_2O$, HF, $SOF_2$, $CuF_2$, $WO_3$). Among these various by-product gases, $N_2$, $O_2$, $CF_4$ is major component. Therefore, the effective separation process is necessary to recycle the $SF_6$ gas from the mixture gas containing $N_2$, $O_2$, $CF_4$. In this study, the membrane separation process was applied to recycle the $SF_6$ gas from the mixture gas containing $N_2$, $O_2$, $CF_4$. The concentration of $SF_6$ gas in gas produced from the electric power industry is over than 90 vol%. Therefore, we made the simulated gas containing $N_2$, $O_2$, $CF_4$, $SF_6$ which the concentration of $SF_6$ gas is minimum 90 vol%. From the results of membrane separation process of $SF_6$ gas from $N_2$, $O_2$, $CF_4$ $SF_6$ mixture gases, PSF membrane shown the highest recovery efficiency 92.7%, in $25^{\circ}C$ and 150 cc/min of retentate flow rate. On the other hand, PC membrane shown the highest recovery efficiency 74.8%, in $45^{\circ}C$ and 150 cc/min of retentate flow rate. Also, the highest rejection rate of $N_2$, $O_2$, $CF_4$ is 80, 74 and 58.9% seperately in the same operation condition of highest recovery efficiency. From the results, we supposed the membrane separation process as the effective $SF_6$ separation and recycle process from the mixture gas containing $N_2$, $O_2$, $CF_4$, $SF_6$.

The Introduction of archival science and the renovation of records Management(since 1999) (기록학의 도입과 기록관리혁신(1999년 이후))

  • Kim, Ik-Han
    • The Korean Journal of Archival Studies
    • /
    • no.15
    • /
    • pp.67-93
    • /
    • 2007
  • This article deals with the short history from 1999 to the present time, how the Korean record and archives management world had grown up, and what the development of the branch of records and archives studies resulted in. First of all, it is looked out upon the transition and feature of each initiative bodies of records management, containing the records producing body, records and archives management body, records and archives professional body, and civil society. As a result, this article points out the disequilibrium state of the records producing body and civil society, for all the growth of records and archives management institutions and records and archives professionals. During the time of establishing the law, the Korean records and archives management had been made a rapid progress by some part of the leading group being to Korean Records and Archives Service and the society of professionals. But it is estimated only the malformed development depending on the model of elites, although we could achieve the establishment of Korean Records and Archives Act. The condition of records and archives management of the Participation Government was distinguish from the state of former times, being driven up the renovation of records and archives management. The main power of the renovation was sought our by overcome of the elite model with the development of archival institutions and professionals extending wide range. Particularly professionals to accept the education of graduate school grew up in quantity and quality and then they let the pattern of the collaboration with archival institutions rake root in Korea. As The Road Map on the Renovation of National Records and Archives Management was made, the government put into practice, so the management of records and archives in Korea could take a step of steady and continuous growth. But the development of the records producing bodies and civil society is staying at the low level as yet. Accordingly it is expected to have the most important means that the professional instruction become to normalize and archivists who posted in public agencies after graduating professional education program discharge their duties. And each public agencies have to speed up to set up the institutions for records management including some archivists so that overcome the condition of underdevelopment as fast as possible.

Development of Carbon Dioxide Emission Factor from Resource Recovery Facility (폐기물자원회수시설의 이산화탄소 배출계수 개발)

  • Kim, Seungjin;Im, Gikyo;Yi, Chi-Yeong;Lee, Seehyung;Sa, Jae-Hwan;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.4 no.1
    • /
    • pp.51-61
    • /
    • 2013
  • To address the problems associated with climate change and energy shortage, Korea has been making efforts to turn waste materials into usable energy. Due to the ongoing efforts to convert waste materials into energy, waste incineration is expanding to utilize the heat generated, and the subsequent greenhouse gas emissions from these waste material incineration are expected to increase. In this study, a municipal waste incineration plant that generates heat and electricity through heat recovery was selected as a subject facility. Methods for estimating the greenhouse gas emissions in the municipal waste incineration plant that was selected as a subject plant were sought, and the greenhouse gas emissions and emission factor were estimated. The $CO_2$ concentrations in discharge gas from the subject facility were on average 6.99%, and the result from calculating this into greenhouse gas emissions showed that the total amount of emissions was $254.60ton\;CO_2/day$. The net emissions, excluding the amount of greenhouse gas emitted from biomass incineration, was shown to be $110.59ton\;CO_2/day$. In addition, after estimating the emissions by separating the heat and electricity generated in the incineration facility, greenhouse gas emission factors were calculated using the greenhouse gas emissions produced per each unit of output. The estimated emission factor for heat was found to be $0.047ton\;CO_2/GJ$ and the emission factor for electricity was found to be $0.652ton\;CO_2/MWh$. The estimated emission factor was shown to be about 17% lower than the $0.783ton\;CO_2/MWh$ emission factor for thermal power plants that use fossil fuels. Waste material types and fossil carbon contents were evaluated as being the factors that have major effects on the greenhouse gas emissions and emission factor.

Estimating the water supply capacity of Hwacheon reservoir for multi-purpose utilization (다목적 활용을 위한 화천댐 용수공급능력 평가 연구)

  • Lee, Eunkyung;Lee, Seonmi;Ji, Jungwon;Yi, Jaeeung;Jung, Soonchan
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.6
    • /
    • pp.437-446
    • /
    • 2022
  • In April 2020, the Korean government decided to operate the Hwacheon reservoir, a hydropower reservoir to supply water, and it is currently under pilot operation. Through the pilot operation, the Hwacheon reservoir is the first among the hydropower reservoirs in Korea to make a constant release for downstream water supply. In this study, the water supply capacity of the Hwacheon reservoir was estimated using the inflow data of the Hwacheon reservoir. A simulation model was developed to calculate the water supply that satisfies both the monthly water supply reliability of 95% and the annual water supply reliability of 95%. An optimization model was also developed to evaluate the water supply capacity of the Hwacheon reservoir. The inflow data used as input data for the model was modified in two ways in consideration of the impact of the Imnam reservoir. Calculating the water supply for the Hwacheon reservoir using the two modified inflows is as follows. The water supply that satisfies 95% of the monthly water supply reliability is 26.9 m3/sec and 24.1 m3/sec. And the water supply that satisfies 95% of the annual water supply reliability is 23.9 m3/sec and 22.2 m3/sec. Hwacheon reservoir has a maximum annual water supply of 777 MCM (Million Cubic Meter) without failure in the water supply. The Hwacheon reservoir can supply 704 MCM of water per year, considering the past monthly power generation and discharge patterns. If the Hwacheon reservoir performs a routine operation utilizing its water supply capacity, it can contribute to stabilizing the water supply during dry seasons in the Han River Basin.