System Level ESD Analysis - A Comprehensive Review I on ESD Generator Modeling

  • Yousaf, Jawad;Lee, Hosang;Nah, Wansoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2017-2032
    • /
    • 2018
  • This study presents, for the first time, state-of-the art review of the various techniques for the modeling of the electrostatic discharge (ESD) generators for the ESD analysis and testing. After a brief overview of the ESD generator, the study provides an in-depth review of ESD generator modeling (analytical, circuit and numerical modeling) techniques for the contact discharge mode. The proposed techniques for each modeling approach are compared to illustrates their differences and limitations.

Characteristics Analysis of Capacitor Discharge Impulse Magnetizing Circuit using SPICE (SPICE를 이용한 커패시터 방전 임펄스 착자 회로의 특성 해석)

  • 백수현;김필수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.206-215
    • /
    • 1994
  • A method for simulating general characteristics and temperature characteristics of discharging SCR of the capacitor discharge impulse magnetizer-magnetizing fixture system using SPICE is presented. This method has been developed which can aid the design, understanding and inexpensive, time-saving of magnetizing circuit. As the detailed characteristic of magnetizing circuit can be obtained, the efficient design of the magntizing circuit which produce desired magnet will be possible using our SPICE modeling. Especially, computation of the temperature rise of discharging SCR is very important since it gives some indication of thermal characteristic of discharging circuit. It is implemented on a 486 personal computer, and the modeling results are checked against experimental measures. The experimental results have been achived using 305[V] and 607[V] charging voltage, low-energy capacitor discharge impulse magnetizer-magnetizing fixture of air cleaner DC motor.

  • PDF

Modeling of the Charge-discharge Behavior of a 12-V Automotive Lead-acid Battery (차량용 12-V 납축전지의 충·방전 모델링)

  • Kim, Ui Seong;Jeon, Sehoon;Jeon, Wonjin;Shin, Chee Burm;Chung, Seung Myun;Kim, Sung Tae
    • Korean Chemical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.242-248
    • /
    • 2007
  • For an optimal design of automotive electric system, it is important to have a reliable modeling tool to predict the charge-discharge behaviors of the automotive battery. In this work, a two-dimensional modeling was carried out to predict the charge-discharge behaviors of a 12-V automotive lead-acid battery. The model accounted for electrochemical kinetics and ionic mass transfer in a battery cell. In order to validate the modeling, modeling results were compared with the experimental data of the charge-discharge behaviors of a lead-acid battery. The discharge behaviors were measured with three different discharge rates of C/5, C/10, and C/20 at operating temperature of $25^{\circ}C$. The batteries were charged with constant current of 30A until the charging voltage reached to a predetermined value of 14.24 V and then the charging voltage was kept constant. The discharge and charge curves from the measurements and modeling were in good agreement. Based on the modeling, the distributions of the electrical potentials of the solid and solution phases, the porosity of the electrodes, and the current density within the electrodes as well as the acid concentration can be predicted as a function of charge and discharge time.

Evaluation Modeling Heat Generation Behavior for Lithium-ion Battery Using FEMLAB (FEMLAB을 이용한 리튬이온전지의 발열특성 평가모델링)

  • Lee, Dae-Hyun;Yoon, Do-Young
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.320-324
    • /
    • 2012
  • In the present study, the discharge characteristics of a lithium-ion battery was evaluated to calculate the rate of heat generation under various discharge rates by mathematical modeling. The modeling and simulation of a pseudo-two dimensional ionic transport system for governing Butler-Volmer equation were carried out by using FEMLAB as a PDE (partial differential equation) solver, where the discharge rate was changed from 5 $A/m^2$ to 25 $A/m^2$. The computational results showed that the concentration of consumed solid-phase lithium at the surface of electrode was increased with increasing discharge rates. While the resulting diffusion limitation occurred shortly, it increased the rate of heat generation even more rapidly for the internal voltage to approach the cutoff voltage of the lithium-ion battery.

Numerical Modeling on the Change in Discharge Performance of the Sluice for Tidal Power Plant According to the Apron Shape (물받이 형상에 따른 조력발전용 수문의 통수성능 변화 수치모델링)

  • Oh, Sang-Ho;Han, In-Suk;Kim, Gunwoo;Jeong, Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.94-102
    • /
    • 2013
  • In this study, numerical modeling was performed to investigate influence of the apron shape on the discharge performance of the sluice for tidal power plant. The numerical modeling was carried out for comparison of the difference in the discharge coefficient when the apron width, slope, and the length of the horizontal section were different, without considering change in the shape of the sluice caisson itself. The modeling result showed that significant discrepancy in terms of the overall discharge performance appeared according to the apron geometry. In order to achieve maximum discharge performance of the sluice caisson, it is desirable to make the design by putting a space equivalent to the width of the sluice caisson on its both sides, by making the apron slope be 1:5, and by keeping length of the horizontal section to be 50 m that is corresponding to the streamwise length of the sluice caisson.

A Fluorescent Modeling for LR Ballast (LR 안정기 적용가능 형광램프 모델링)

  • 이진우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.267-270
    • /
    • 2002
  • The fluoescent lamp has been successfully modeled by employing the radial variation of particle density and considering driving circuit effects on the characteristics of discharge process. The electron energy distribution is assumed to have a Maxwellian. The electron mobility and the ambipolar diffusion coefficients are considered to vary with an electron energy rather than a simple uniform value. Energy states of mercury atom in the discharge process are regarded as six levels rather than simple 4 or 5 levels. These discharge processes have been accurately solved by numerically employing mixed the FDM and the 2nd Runge-Kutta method. This model was applied to analyzing real circuit. Simulation and experimental results were presented to verify the feasibility of the modeling. Simulation and experimental results were presented to verify the feasibility of the modeling.

  • PDF

Pollutant Flux Releases During Summer Monsoon Period based on Hydrological Modeling in Two Forested Watersheds, Soyang Lake

  • Kang, S.H.
    • Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • In this study, specific pollutant releases during the Asian monsoon season were estimated and the information was applied to the non-point pollutant sources management from two forested watersheds of the Soyang Lake. The two watersheds are part of the 2,703 km2 Soyang Lake watershed in the northern region of the Han River. The outlets of the two watersheds were respectively analyzed for continuous water quality concentration and for discharge during various single rainfall events. Statistical power function methods are utilized to compare stream discharge and pollutant flux release during the study period. Based on the monitoring data during the study period, the specific load flux method using simulated discharge was conducted and validated in the two watersheds. The model predictions corresponded well with the measured and calculated pollutant releases. The modeling approach taken in this study was found to be applicable for the two forested watersheds.

Water quality forecasting on upstream of chungju lake by flow duration (충주호 상류지역의 유황별 장래수질예측)

  • 이원호;한양수;연인성;조용진
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • In order to define about concern with discharge and water-quality, it is calculated drought flow, low flow, normal flow and wet flow in Chungju watershed from flow duration analysis. Water quality modeling study is performed for forecasting at upstream of Chungju lake. It is devided method of modeling into before and after the equipment of environmental treatment institution. And it is estimated the change of water quality. Before the equipment of environmental treatment, BOD concentration is increased from 23000 to 2006 years at all site and decrease on 2012 years. The rate of increasing BOD concentration is showed height between 2000 years and 2003 years most of all site. And after the equipment of environmental treatment, it is showed first grade of BOD water quality in most of sample site beside Jucheon river. The result of water quality modeling using drought flow showed that a lot of pollution occurred. And water quality using wet flow is good, so much discharge make more improve water quality than little discharge.

System Level ESD Analysis - A Comprehensive Review II on ESD Coupling Analysis Techniques

  • Yousaf, Jawad;Lee, Hosang;Nah, Wansoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2033-2044
    • /
    • 2018
  • This study presents states-of-the art overview of the system level electrostatic discharge (ESD) analysis and testing. After brief description of ESD compliance standards and ESD coupling mechanisms, the study provides an in-depth review and comparison of the various techniques for the system level ESD coupling analysis using time and frequency domain techniques, full wave electromagnetic modeling and hybrid modeling. The methods used for improving system level ESD testing using troubleshooting and determining the root causes of soft failures, the optimization of ESD testing and the countermeasures to mitigate ESD problems are also discussed.

Hourly SWAT Watershed Modeling for Analyzing Reduction Effect of Nonpoint Source Pollution Discharge Loads (비점원오염 저감효과 분석을 위한 시단위 SWAT 유역 모델링)

  • Jang, Sun Sook;Ahn, So Ra;Choi, Joong Dae;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.1
    • /
    • pp.89-97
    • /
    • 2015
  • This study is to assess the effect of non-point source pollution discharge loads between tillage and no-tillage applications for upland crop areas using SWAT (Soil and Water Assessment Tool) watershed modeling. For Byulmi-cheon small rural catchment ($1.17km^2$) located in upstream of Gyeongan-cheon watershed, the rainfall, discharge and stream water quality have been monitored in the catchment outlet since 2011. The SWAT model was calibrated and validated in hourly basis using 19 rainfall events during 2011-2013. The average Nash-Sutcliffe model efficiency and $R^2$ (determination coefficient) for streamflow were 0.67 and 0.79 respectively. Using the 10 % surface runoff reduction from experiment results for no-tillage condition in field plots of 3 % and 8 % slopes under sesami cultivation, the soil saturated hydraulic conductivity for upland crop areas was adjusted from 0.001 mm/hr to 0.0025 mm/hr in average. Under the condition, the catchment sediment, T-N (total nitrogen, TN), and T-P (total phosphorus, TP) discharge loads were reduced by 6.9 %, 7.4 %, and 7.7 % respectively.