• 제목/요약/키워드: Discharge method

검색결과 3,029건 처리시간 0.027초

에어컨 실외기 토출그릴 형상 최적화 (A Study on the Optimization of Discharge Grille of Outdoor Unit of Air Conditioner)

  • 최석호;오세기;김현종;진근호;오시영;김병순
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.726-732
    • /
    • 2011
  • The aerodynamic and aeroacoustic performance of discharge grille of outdoor unit of air-conditioner was investigated in this study. Discharge grille is one of outdoor unit's important parts to affect the flow rate and Overall Sound Pressure Level(OSPL). New type of discharge grille was suggested based on the results of numerical simulation. To simulate the flow pattern near the propeller fan, commercial flow solver FLUENT was used. Sliding mesh method was used for rotating propeller fan and initial condition for unsteady model was calculated by Multiple Reference Frame(MRF) method. To minimize the interaction noise between fan blade wake and discharge grille, new discharge grille has radial rib which is aligned with trailing edge of fan blade. And inclined radial rib was adopted for reducing flow rate drop in discharge grille. The optimization of inclined angle of radial grille was performed experimentally.

연직배수재가 타설된 지반의 복합통수능 해석 (Composite Discharge Capacity Analysis of Vertical Drain Installed in Ground)

  • 김창영;곽노경;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1167-1174
    • /
    • 2008
  • Vertical drain method, which is one of the soft ground improvement methods, shorten s drain path to accelerate consolidation process and is applied in many sites. At a recent, composite discharge capacity experiment that analyze discharge amount by consolidation behavior with overburden pressure of soft ground in laboratory, simulates similarly with actuality. Geotechnical engineering problems such a s soft ground improvement are solved by numerical analysis by development of computer and numerical analysis techniques. Numerical analysis does that result is contrary by user's inexperience for choice of constitution model and application of analysis method. Therefore, this thesis experiments on composite discharge capacity test and study discharge capacity of drain and consolidation behavior of soft ground installed prefabricated vertical drain boards. Also, This thesis studied reasonable input parameters and constitution model by compare results of composite discharge capacity test and numerical analysis using PLAXIS that is 2D finial element numerical analysis program.

  • PDF

평균유속공식을 활용한 하천 유량 산정 (Estimation of Discharge Using Mean Velocity Equations)

  • 추태호;고덕구;이상진
    • 한국수자원학회논문집
    • /
    • 제43권3호
    • /
    • pp.265-273
    • /
    • 2010
  • 본 연구에서는 기존의 수위만을 고려하여 작성된 수위-유량관계곡선식을 개선하기 위하여 경심, 하상경사, 수심 등 비교적 쉽게 취득할 수 있는 하천의 수리특성인자를 활용하여 유량을 산정할 수 있는 방법을 제안하였다. 알버타대학에서 제공된 보고서 내용 중 수리실험실 및 자연하천의 수리자료를 활용하여 평균유속 공식인 Manning식과 Chezy식으로부터 하천의 수리학적 특성이 반영된 조도계수 n값과 C값을 산정하고 이를 토대로 유량을 산정하였다. 제안된 유량산정 방법은 실측치에 근사하여 정확도가 개선됨을 확인하였으며 기존의 수위-유량관계곡선식에서 추정된 유량과 비교하고 그 적용성을 검토하였다.

방폭형 제전기의 개발 및 평가방법에 관한 연구 (A Study on the Development of an Electrostatic Eliminator and Evaluating Method of Explosion-Protection Construction)

  • 최상원
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.49-54
    • /
    • 2014
  • Electrostatic eliminators are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, and ultraviolet and glow discharge. Among them, corona discharge is generally used, because the corona discharge can easily and economically produce positive and negative ions including electrons in air at atmospheric pressure. But it is necessary to equip explosion-protection electrostatic eliminators wherever hazardous atmosphere. The electrostatic eliminators and their testing method of explosion-protection type have been developed in this research. The contents and scope of the research as follows; developing the type 'Ex s IIB T4' electrostatic eliminator of explosion-protection; developing the type 'Ex s d IIB T4' electrostatic eliminator of explosion-protection; developing the explosion-protection performance testing method of electrostatic eliminator for using AC power source.

새로운 구동방식을 이용한 어드레스 방전 지연시간의 감소 (The Reduction of Address Discharge Delay Time Using a New Driving Method)

  • 송근영;김근수;서정현;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.123-125
    • /
    • 2004
  • In order to achieve high efficiency and low cost, new high-speed addressing method is suggested. This can be achieved by reducing the address discharge delay time through the priming effect. This paper suggests a new ADR (Address During Reset) driving method which provides priming particles by using a separated driving method without adding auxiliary electrode or auxiliary discharge. The experimental results show an approximately loons reduction in the formative delay time of address discharge and a reduction in jitter of over 200ns. Also, due to enough time being available for reset, there was a reduction in light emitted during reset of about 29% which improved the dark contrast ratio considerably.

  • PDF

$SF_6$ 가스 방전 특성의 유한요소해석 (A finite Element Analysis on the discharge characteristics of $SF_6$ gas)

  • 최승길;심재학;강형부
    • 한국전기전자재료학회논문지
    • /
    • 제13권3호
    • /
    • pp.265-272
    • /
    • 2000
  • In this paper the corona discharge in SF$_{6}$ gas used as insulating material in lots o high voltage equipment, is simulated by finite element method with Flux-Corrected Transport(FCT) method. By application of proposed method the negative corona discharge characteristics in needle to plane electrode is analyzed with time step. For the accuracy of analysis the secondary electron emission by photon and ion are also considered as well as the accuracy of analysis the secondary electron emission by photon and ion are also considered as well as townsend first ionization and electron attachment. The calculated results show that the electric field intensity between anode and ion group is decreased as times go-by according to field distortion by those space charge. Accordingly the electron density is decreased strongly by the attatchment effect of SF6 gas so that the corona discharge becomes extinguished abruptly.y.

  • PDF

GCP공법의 복합통수능 효과 분석 (An Analysis of the Composite Discharge Capacity Effect with GCP Method)

  • 박민철;권혁찬;신효희;장기수;이송
    • 한국지반환경공학회 논문집
    • /
    • 제12권12호
    • /
    • pp.37-46
    • /
    • 2011
  • 연직배수공법은 효과적인 연약지반 압밀촉진 방법으로 적용빈도가 증가하고 있다. 연직배수 공법 중에서 PBD공법은 현재 가장 많이 사용되고 있는 압밀촉진공법으로 경제성 및 시공성 면에서 우수하나, 환경오염 및 대심도의 경우 배수재의 굴곡으로 인한 통수능 저하 문제점을 지니고 있다. SCP공법은 과거에 통수능력이 우수하여 많이 사용되었으나, 재료의 수급불균형으로 인한 가격급등으로 현재는 과거보다 사용이 많이 줄고 있는 실정이다. 이에 따른 대책 재료로 쇄석말뚝을 이용한 GCP공법이 대두되고 있다. 따라서 GCP공법의 통수능 효과를 분석하기 위하여 ${\phi}38{\times}70cm$의 원형토조를 이용하여 쇄석말뚝과 비교대상인 모래말뚝, PBD공법의 3종류의 연직배수재를 이용하여 복합통수능 실험을 실시하였다. 또한, 쇄석말뚝의 클로깅(Clogging) 범위를 파악하기 위하여 $1.0m{\times}0.5m{\times}1.1m$ 대형토조를 정면에 투명 아크릴로 제작하여 하중단계별 클로깅(Clogging) 범위를 분석하였다. 복합통수능 시험결과 하중증가에 따른 간극비 감소 및 클로깅(Clogging) 현상이 많이 발생한 GCP공법에서 가장 적게 발생하였으며, 또한 GCP 공법의 클로깅(Clogging)의 범위는 거의 10% 내에서 발생하는 것으로 분석되었다.

플라즈마 디스플레이 패널의 고속 구동을 위한 세폭 펄스 어드레스 방전특성 (Discharge Characteristics of Narrow Width Pulse Addressing for the High-Speed Driving of Plasma Display Panels)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.13-19
    • /
    • 2007
  • 본 연구는 1,080개의 주사선수를 가지는 full-HD PDP를 위한 새로운 고속구동방식에 관한 것으로 고속 어드레스에 의한 표시방전의 방전특성을 고찰하여 새로운 구동방식의 특성을 평가하였다. 이 구동방식에서 어드레스 펄스의 폭이 좁아지면 최초 표시방전의 상대적 방전강도와 방전지연시간은 그 영향을 받는다. 어드레스 펄스의 인가위치의 변화는 방전강도와 무관하나 방전지연시간에는 영향을 미친다. 그러나 어드레스 펄스의 인가위치가 [$6{\mu}s$]이내이고 펄스의 폭이 [$0.7{\mu}s$]이내라면, 어드레스 펄스의 인가위치나 폭에 무관하게 안정된 표시방전을 유도할 수 있다. 실험결과로부터 폭이 좁은 어드레스 펄스를 사용하는 고속구동기술은 축적되는 벽전하의 부족으로 인해 공간전하의 영향에 매우 민감하다는 것을 알았다.

Analysis of the Influence of Electrical Discharge Machining Parameters on Surface Roughness of CK45

  • Abedi, Esmail;Daneshmand, Saeed;Karimi, Iman;Neyestanak, A. A. Lotfi
    • Journal of Electrochemical Science and Technology
    • /
    • 제6권4호
    • /
    • pp.131-138
    • /
    • 2015
  • Electrical discharge machining is an unconventional machining process in which successive sparks applied to machine the electrically conductive materials. Any changes in electrical discharge machining parameters lead to the pieces with distinct surface roughness. The electrical discharge machining process is well applied for high hardness materials or when it is difficult to use traditional techniques to do material removing. Furthermore, this method is widely applied in industries such as aerospace, automobile, molding, and tool making. CK45 is one of the important steels in industrial and electrical discharge machining can be considered as a proper way for its machining because of high hardness of CK45 after thermal operation of the electrical discharge machining process. Optimization of surface roughness as an output parameters as well as electrical discharge machining parameters including current, voltage and frequency for electrical discharge machining of CK45 has been studied using copper tools and kerosene as the dielectric. For such a purpose and to achieve the precise statistical analysis of the experiment results design of experiment was applied while non linear regression method was chosen to assess the response of surface roughness. Then, the results were analyzed by means of ANOVA method and machining parameters with more effects on the desired outputs were determined. Finally, mathematical model obtained for surface roughness.

PDP의 ADS 구동방식에서의 초기화 방전특성에 관한 연구 (A Study on the Characteristics of Reset Discharge in the ADS Driving Method for the PDPs)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.17-22
    • /
    • 2003
  • 본 연구에서는 mP의 ADS 구동방식에서 초기화기간의 프라이밍 방전 특성에 대하여 실험적인 해석을 하였다. 방전에 의해 축적되는 벽전하의 총량과 벽전하가 축적되는 시간은 프라이밍 펄스의 폭과 무관하다. 또한 과잉 벽전하에 의한 자기소거 방전은 프라이밍 방전에 의한 벽전하량과 관계가 있으며 또한 프라이밍 방전에 의해 생성되는 공간전하와도 관계가 있다. 실험결과 프라이밍 펄스 폭은 8[$\mu\textrm{s}$], 전압은 163[V] 정도가 최적이다. 그리고 자기소거방전을 돕는 공간전하는 파라이밍 방전이 발생한 직후로부터 약 16[$\mu\textrm{s}$] 동안 존재한다. 그러므로 효과적인 초기화 과정을 위한 프라이밍 펄스의 폭은 16[$\mu\textrm{s}$] 이내가 적당하다.