• Title/Summary/Keyword: Discharge gap

Search Result 426, Processing Time 0.039 seconds

Design and Development of Micro Combustor (II) - Design and Test of Micro Electric Spark discharge Device for Power MEMS - (미세 연소기 개발 (II) - 미세동력 장치용 미세 전극의 제작과 성능평가 -)

  • Gwon, Se-Jin;Lee, Dae-Hun;Park, Dae-Eun;Yun, Jun-Bo;Han, Cheol-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.524-530
    • /
    • 2002
  • Micro electric spark discharge device was fabricated on a FOTURAN glass wafer using MEMS processing technique and its performance of electron discharge and subsequent formation of ignition kernel were tested. Micro electric spark device is an essential subsystem of a power MEMS that has been under development in this laboratories. In a combustion chamber of sub millimeter scale depth, spark electrodes are formed by electroplating Ni on a base plate of FOTURAN glass wafer. Optimization of spark voltage and spark gap is crucial for stable ignition and endurance of the electrodes. Namely, wider spark gaps insures stable ignition but requires higher ignition voltage to overcome the spark barrier. Also, electron discharge across larger voltage tends to erode the electrodes limiting the endurance of the overall system. In the present study, the discharge characteristics of the proptotype ignition device was measured in terms of electric quantities such as voltage and currant with spark gap and end shape as parameters. Discharge voltage shows a little decrease in width of less than 50㎛ and increases with electrode gap size. Reliability test shows no severe damage over 10$\^$6/ times of discharge test resulting in satisfactory performance for application to proposed power MEMS devices.

Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations

  • Zhang, Yu;Liu, Li-Juan;Miao, Jin-Song;Peng, Zu-Lin;Ouyang, Ji-Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1174-1180
    • /
    • 2015
  • We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.

A Study on Behaviour and Characteristics of Spark Discharge in Spark Ignition System (스파크 점화 시스템의 방전 거동 및 특성에 관한 연구)

  • Lee Myung Jun;Hall Matt;Ezekoye Ofodike A.;Matthews Ron;Chung Sung Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.100-108
    • /
    • 2006
  • Time-resolved current and voltage measurements for an inductive automotive spark system were made. Also presented are measurements of the total energy delivered to the spark gap. The measurements were made in air for a range of pressures from 1-18atm, at ambient temperatures. The measured voltage and current characteristics were found to be a function of many ignition parameters; some of these include: spark gap distance, internal resistance of the spark plug and high tension wire, and pressure. The voltages presented were measured either at the top of the spark plug or at the spark gap. The measurements were made at different time resolutions to more accurately resolve the voltage and current behavior throughout the discharge process. This was necessary because the breakdown event occurs on a time scale much shorter than the arc and glow phases. The breakdown, are, and glow voltages were found to be functions of spark plug resistance, gas density, and spark plug gap as expected from the literature. Spark duration was found to decrease as either pressure or gap was increased. The transition from the arc to glow phase is usually distinguished by a sudden rise in the voltage across the gap. At pressures above about 7atm this transition was not observed suggesting that a glow phase was not present. Energy delivered to the gap increased with increasing pressure. The effective resistance of the spark gap during discharge was about twice as large for the glow phase as the arc phase.

Experimental Studies on the Motion and Discharge Behavior of Free Conducting Wire Particle in DC GIL

  • Wang, Jian;Wang, Zhiyuan;Ni, Xiaoru;Liu, Sihua
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.858-864
    • /
    • 2017
  • This study aims to restrain free conducting wire-type particles which are commonly and dangerously existing within DC gas-insulated transmission lines. A realistic platform of a coaxial cylindrical electrode was established by using a high-speed camera and a partial discharge (PD) monitor to observe the motion, PD, and breakdown of these particles. The probabilities of standing or bouncing, which can be affected by the length of the particles, were also quantitatively examined. The corona images of the particles were recorded, and particle-triggered PD signals were monitored and extracted. Breakdown images were also obtained. The air-gap breakdown with the particles was subjected to mechanism analysis on the basis of stream theory. Results reveal that the lifting voltage of the wire particles is almost irrelevant to their length but is proportional to the square root of their radius. Short particles correspond to high bouncing probability. The intensity and frequency of PD and the micro-discharge gap increase as the length of the particles increases. The breakdown voltage decreases as the length of the particles decreases.

Observation and Characteristics of Ozonizer using Injection Needle Electrode (주사바늘 전극형 오존발생기 특성 연구)

  • Park, Hyun-Mi;Kwon, Young-Hak;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.77-82
    • /
    • 2015
  • Ozone is a powerful disinfectant and oxidizing agent, and it is used in a wide range of applications, such as waste water treatment, food processing, etc.. There is also a great potential of using ozone in new emerging medical applications, such as ozone dentistry and ozone oxygen therapy. For these purposes, simple, small, compact and efficient sources of ozone are needed. In this study, in order to increase the current-voltage range of the discharge and to avoid the overheating of the gas in the ozonizer we suggested ozonizer of injection needle and plate electrode type(INP Type) with the gas through the needle. A ozonizer of INP type have been investigated by focusing on ozone concentration and yield according to flow rates and Gap of two electrodes. The results of studies of ozone production for DC corona discharge in oxygen at atmospheric pressure about the ozonizer of INP type. The ozone concentration and the generation yield increased as the gap of two electrodes and gas flow were decreased. Also, when the gap of two electrodes and gas flow with no change, the ozone concentration and generation yield each have variation of direct proportion and inverse proportion with discharge voltage.

Trial Manufacture and Characteristics of a Multi-discharge Type ozonizer(I) (다중방전형 오존발생기의 試作 및 特性(I))

  • Song, Hyeon-Jik;Lee, Gwang-Sik;Park, Won-Ju;Lee, Dong-Heon;Kim, Geum-Yeong;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.7
    • /
    • pp.533-541
    • /
    • 1999
  • Multi-discharge type ozonizer(MDO) using superposed silent discharge has been designed and manufactured. It consists of three electrodes( central electrode, internal electrode, and external electrode ) and double gaps( gap between central electrode and internal electrode, gap between internal electrode and external electrode ). Therefore, ozone is generated by superposing silent discharges generated between the gaps respectively. And the MDO consists of three types of superposed discharge ozonizers according to voltage appling method for each electrode ; A.C. high voltages are applied two of three electrodes with phase difference of 180[˚], the other electrode is a ground. This paper describes that discharge and ozone generation characteristics of MDO which comprising central electrode and internal electrode applied A.C. high voltages with phase difference of 180[˚] respectively, and the grounded external electrode. As a result, the maximum ozone concentration, generation, and yield can be obtained 10208[ppm], 6.4[g/h], and 280[g/kwh] respectively.

  • PDF

The Characteristics of Superposed Ozonizer using Three-Phase Voltage (3상전압을 이용한 중첩방전형 오존발생기의 특성)

  • Kim, Yeong-Hun;Chun, Byung-Joon;Song, Hyun-Jig;Youn, Young-Dae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2259-2261
    • /
    • 1999
  • In this paper, an ozonizer, which can generate individual and superposed silent discharge, using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode) and 2 gaps(gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the quantity of supplied gas($O_2$). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum values was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF

Study on Characteristics of DBD Plasma Actuator as Design Parameters for Plasma Flow Control (플라즈마 유동제어를 위한 DBD 플라즈마 액츄에이터의 설계변수에 따른 특성 연구)

  • Yun, Su-Hwan;Kwon, Hyeok-Bin;Kim, Tae-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.6
    • /
    • pp.492-498
    • /
    • 2012
  • Characteristics of DBD(Dielectric Barrier Discharge) plasma actuator as design parameters were investigated for plasma flow control. Flow velocity and power consumption of the DBD plasma actuator were measured according to the design parameters such as discharge voltage and frequency, gap, width and length of electrode, and the thickness of dielectric barrier. The flow velocity and power consumption increased as the discharge voltage and frequency increased. As the electrode gap increased, the flow velocity increased with decreasing the power consumption, whereas high voltage was required for the plasma discharge. The flow velocity increased as the upper-electrode width decreased, and as the lower-electrode width increased at the constant power consumption. The performance of the DBD plasma actuator can be estimated at the given discharge and geometry conditions.

The Characteristics of a Superposed Discharge Type Ozonizer Using Vacuum Discharge Tube (진공 방전관을 이용한 고농도 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig;Lee, Chang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.60-67
    • /
    • 2005
  • The superposed discharge type ozonizer of high ozone concentration using vacuum discharge tube has been designed and manufactured. It consists of three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode), is a superposed silent discharge type ozonizer for which the AC high voltages applied to the central electrode within discharge tube and the internal electrode has a $180{[^\circ]}$ phase difference and for which the external electrode is a ground. Ozone is generated by overlapping silent discharge between central electrode and external electrode, and silent discharge between internal electrode and external electrode. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, high ozone concentration can be obtained 8840[ppm].

The study on micro discharge characteristics for DC Plasma Display (직류 플라즈마 디스플레이를 위한 미소방전특성연구)

  • Cho, Jung-Soo;Park, Chung-Hoo;Kim, Gyu-Sub;Kawk, Byung-Goo;Ha, Hong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1413-1416
    • /
    • 1995
  • Plasma Display(PDP) was successfully demonstrated on 30-60inch display panel. Research for mass production is also been accelerating. The basic study of PDP are mainly focused on understanding of micro discharge in each cell In this paper, DC PDP with Ag electrode is made and the discharge charcateristics in micro gap is studied with the variation of the distance of electrode gap and the pressure in discharge cell.

  • PDF