• 제목/요약/키워드: Discharge gap

검색결과 426건 처리시간 0.03초

직렬 갭 피뢰기의 흡습시 전극표면의 변화 및 특성 (Characteristics and Change of Electrode Surface in Moisture Absorption on the Series Gap Surge Arrester)

  • 조한구;김향숙
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1172-1175
    • /
    • 2003
  • The characteristics and change of electrode surface about Gap type surge arrester for protect DC subway rail were investigated with moisture absorption. Compared that tested about DC/AC discharge commencement voltage, residual voltage, Impulse, square wave impulse for DC rail surge arrester about Gap type surge arrester of moisture absorption state. The AC discharge commencement voltage acted greatly effect of moisture absorption than the DC discharge commencement voltage test.

  • PDF

Simulation of Low Temperature Plasmas for an Ultra Violet Light Source using Coplanar Micro Dielectric Barrier Discharges

  • Bae, Hyowon;Lee, Ho-Jun;Lee, Hae June
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.138-144
    • /
    • 2016
  • The discharge characteristics of pulse-driven coplanar micro barrier discharges for an ultraviolet (UV) light source using Ne-Xe mixture have been investigated using a two-dimensional fluid simulation at near-atmospheric pressure. The densities of electrons, the radiative excited states, the metastable excited states, and the power loss are investigated with the variations of gas pressure and the gap distance. With a fixed gap distance, the number of the radiative states $Xe^*(^3P_1)$ increases with the increasing driving voltage, but this number shows weak dependency on the gas when that pressure is over 400 Torr. However, the number of the radiative states increases with the increase of the gap distance at a fixed voltage, while the power loss decreases. Therefore, a long gap discharge has higher efficiency for UV generation than does a short gap discharge. A slight change in the electrode tilt angle enhances the number of radiative species 2 or 3 times with the same operation conditions. Therefore, the intensity and efficiency of the UV light source can be controlled independently by changing the gap distance and the electrode structure.

2차원 시뮬레이션을 이용한 전극 간격에 따른 방전셀 내부의 특성 연구 (A Study on the Characteristics on a Discharge Cell by the Electrode Gap Using 2-D Simulation)

  • 이돈규
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.524-528
    • /
    • 2019
  • 다양한 종류의 방전 셀이 존재하고 있지만, 공통적으로 모든 방전 셀은 보다 낮은 구동 전압에서 보다 높은 효율 특성을 가지는 것을 우선적인 목표로 한다. 이러한 특성 개선을 위해 방전셀 내부의 방전 경로를 길게 하거나 구동 가스의 성분을 변화시키는 연구가 많이 이루어진다. 본 논문에서는 2차원 유체 시뮬레이션을 이용하여 방전전극 사이의 간격에 따른 방전전압 (개시전압 및 유지전압) 및 휘도와 효율의 변화를 계산하였다. 또한, 다양한 하전입자와 여기입자 및 파장별 진공자외선의 변화를 살펴보고 휘도와 효율의 원인을 연구해 보았다.

Dependence of Ozone Generation in a Micro Dielectric Barrier Discharge on Dielectric Material and Micro Gap Length

  • Sakoda, Tatsuya;Sung, Youl-Moon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.201-206
    • /
    • 2004
  • In order to investigate the optimum conditions for the effective ozone formation in a dielectric barrier discharge, measurements of ozone concentration were carried out for various conditions such as the gap length, the dielectric material and the operating gas. It was found that the optimum discharge conditions differed exceedingly in the types of operating gases and dielectric materials. In dry air, dielectric material with low dielectric constant and thermal conductivity, which might contribute to the restriction of the gas temperature rise in the discharge region, proved effective in obtaining both high ozone yield and concentration. The optimum gap length was considered to be in the range of 600-800 mm. In oxygen, using a quartz glass disk as a dielectric material, the required condition to obtain the high ozone yield and concentration was expanded.

AC-PDP의 방전갭과 가스압력에 따른 Xe-Kr-Ne mixture gas 방전특성 연구 (A research on the discharge characteristics of Xe-Kr-Ne mixture gas in discharge gap and gas pressure of ac-PDP)

  • 한문기;하창승;이돈규;이해준;이호준;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.171-172
    • /
    • 2007
  • PDP의 luminous efficacy의 향상을 위해서는 동작가스의 연구가 매우 중요하다. 본 논문에서는 bolsig simulator를 사용하여 여러 비율의 Xe+Kr+Ne 3원가스 시뮬레이션을 통하여 각 가스입자들에 전달되는 이온화에너지, 여기에너지를 조사하였다. 실험에서 short discharge gap과 long discharge gap을 가진 7인치 테스트 패널 2개를 사용하여 가스압력과 Xe+Kr+Ne 혼합비를 변화시켜가며 discharge voltage, luminance, luminous efficacy를 측정하여, 방전특성을 연구하였다.

  • PDF

LCD 백라이트용 면방전형 FFL의 방전 특성 (Discharge Characteristics of Surface Discharge Type FFL for LCD Backlighting)

  • 임민수;윤성현;신유섭;정득영;권순석;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1786-1788
    • /
    • 1999
  • In this paper, we studied Surface Discharge Type Flat Fluorescent Lamp with High Luminance for LCD Backlighting, Liquid Crystal display(LCDs) demand the use of fluorescent lamp as the backlighting source. This lamp is Surface Discharge Type structure with a pair of Sodalime glass, insulator layer, phosphor layer, and Xe gas gap. In spite of its simple structure, the lamp has uniform and stable discharge over entire volume. Till now, we measured the current-voltage(V-I), Firing Voltage, Sustain Voltage for 0.5mm, 1mm electrode gap. In experiment result, long gap cell structure cause high firing voltage. The rising in firing voltage in long gap structure could not be explained by paschen's law because of non-uniform electric field.

  • PDF

유량변화와 지류유입에 따른 금강의 수질 변화 (Influence of River Discharge Fluctuation and Tributary Mixing on Water Quality of Geum River, Korea)

  • 심무준;이수형
    • 한국물환경학회지
    • /
    • 제31권3호
    • /
    • pp.313-318
    • /
    • 2015
  • To study the influence of changes in river discharge on water quality of the main stem of the Geum River, we investigated variation of inflow load from tributaries with river discharge. We also studied the mixing behavior of pollutants during mixing of waters of the main stem and Gap Stream. For this study, we collected water quality data such as suspended solids (SS), biochemical oxygen demand (BOD), chemical oxygen demand (COD), total organic carbon (TOC), total nitrogen (TN) and total phosphorus (TP) representing pre-monsoon, monsoon, and post-monsoon events of 2013 from a website of Water Information System. Based on inflow load, the Gap and Miho streams may be ones of tributaries which may largely influence water quality of main stem in upper river region. The Suksung and Nonsan Streams seemed to further affect water quality downstream. Results of modified EMMA indicated SS and TP may have another source(besides Gap Stream) at pre-monsoon, monsoon, and post-monsoon period. In contrast, TN and organic matter (BOD, COD, TOC) were conservative at pre-monsoon and post-monsoon. However, when river discharge increased, these pollutants may also came from unspecified non-point sources. Therefore, we need to attempt to find non-point sources for the pollutants in the main channel of upper Geum River region.

AC-PDP의 유지방전 전극사이의 간격과 어드레스 방전 특성과의 상관성 분석 (The Analysis of the Correlation between the Sustain-Electrode Gap of an AC-PDP and Address Discharge Characteristics)

  • 이영준;최수삼;박세광;김용득
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.239-244
    • /
    • 2006
  • To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, and sustain period for luminance in 1 TV-frame, and also the display quality. To accomplish them, the development of the technology for the fast address discharge is required. In this paper, the correlation between the sustain-electrode gap and address discharge characteristics for the high-speed addressing was analyzed using the measurements of dynamic voltage margins. Results showed that the narrower the gap between the sustain electrodes, the narrower the with of the scan pulse became and a dynamic margin of data voltage of 29.2 V was obtained at scan pulse width of $1.0{\mu}s\;and\;V_{ramp}$ of 240 V for driving 4-inch test penal, which the gap between sustain electrodes was $65{\mu}m$.

방전공격과 방전극 형상이 오존발생농도에 미치는 영향 (Effects of Corona Electrode Shape and Discharge Gap Spacing on Ozone Concentration)

  • 박승록;이재찬;정성진;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권4호
    • /
    • pp.169-175
    • /
    • 2001
  • Ozone has been widely applied to many industrial fields because of its strong oxidation power, Therefore, the studies have been carried out for the methods on an effective and high concentration ozone generation. The silent or surface discharge type ozone generators have been mainly used for high concentration ozone generation in many fields of applications. But these two types of ozone generators have shortcomings to be improved. In this study, the ozone generator which improved the shortcomings of above ozone generators was proposed and fabricated for the high concentration ozone generation. And the proposed ozone generator could generate the surface and barrier discharge simultaneously. For this purpose, a mesh type discharge electrode was proposed and studied as a function of the widths output maximum ozone concentration of 2.96[vol%] was obtained at 5.6[kV], 830[mA], for 0.3[mm] width and 0.8[mm] vacancy of the mesh electrode and gap spacing of 0.65[mm] respectively.

  • PDF

형조 방전가공에서 극간 전압과 가공 안정성에 관한 연구 (A Study on the Gap Voltage and Machining Stability in Diesinking Electrical Discharge Machining)

  • 김광열;이상민;이건기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.429-436
    • /
    • 2003
  • The electrical discharge machining(EDM) with Si electrode instead of Gr or Cu electrode. made enormous effects on the surface. machining time, anti-caustic workpiece surface and so on In this paper. we experimented on the inter-role distance during discharge the electrical phenomenon of inter-pole, the distribution of discharge point. the distribution of off load time. etc., using Si electrode Cu electrode and Gr electrode under the same machining condition. As a result of a large quantity generated exclusive powders. the performance of the EDM using Si electrode. compared with EDM using others. is improved. We show that the quantities of those make far pole-gap discharge and discharge scatter under stable machining status possible.