• Title/Summary/Keyword: Discharge current

Search Result 1,799, Processing Time 0.032 seconds

Study on the deposition rate and vapor distribution of Al films prepared by vacuum evaporation and arc-induced ion plating (증착방법에 따른 Al 피막의 증착율 및 증기분포에 관한 연구)

  • 정재인;정우철;손영호;이득진;박성렬
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.207-215
    • /
    • 2000
  • Al films on cold-rolled steel sheet have been prepared by vacuum evaporation and arc-induced ion plating, respectively, and the evaporation rate and vapor distribution (thickness distribution over the substrate) have been investigated according to deposition conditions. The arc-induced ion plating (AIIP) method have been employed, which makes use of arc-like discharge current induced by ionization electrode located near the evaporation source. The AIIP takes advantage of high ionization rate compared with conventional ion plating, and can be carried out at low pressure of less than $10^{-4}$ torr. Very high evaporation rate of more than 2.0 mu\textrm{m}$/min could be achieved for Al evaporation using alumina liner by electron beam evaporation. The geometry factor n for the $cos^{n/\phi}$ vapor distribution, which affects the thickness distribution of films at the substrate turned out to be around 1 for vacuum evaporation, while it features around 2 or higher for ion plating. For the ion plated films, it has been found that the ionization condition and substrate bias are the main parameters to affect the thickness distribution of the films.

  • PDF

Effect of Relative Humidity, Disk Acceleration, and Rest Time on Tribocharge Build-up at a Slider-Disk Interface of HDD (HDD에서 상대습도, 디스크 가속도, 정지시간이 슬라이더-디스크 인터페이스의 마찰대전 발생에 미치는 영향)

  • Hwang J.;Lee D.Y.;Lee J.;Choa S.H.
    • Tribology and Lubricants
    • /
    • v.22 no.2
    • /
    • pp.59-65
    • /
    • 2006
  • In hard disk drives as the head to disk spacing continues to decrease to facilitate recording densities, slider disk interactions have become much more severe due to direct contact of head and disk surfaces in both start/stop and flying cases. The slider disk interaction in CSS (contact-start-stop) mode is an important source of particle generation and tribocharge build-up. The tribocharge build-up in the slider disk interface can cause ESD (electrostatic discharge) damage. In turn, ESD can cause severe melting damage to MR or GMR heads. The spindle speed of typical hard disk drives has increased in recent years from 5400 rpm to 15000 rpm and even higher speeds are anticipated in the near future. And the increasing disk velocity leads to increasing disk acceleration and this might affect the tribocharging phenomena of the slider/disk interface. We investigated the tribocurrent/voltage build-up generated in HDD, operating at increasing disk accelerations. In addition, we examined the effects with relative humidity conditions and rest time. We found that the tribocurrent/voltage was generated during pico-slider/disk interaction and its level was about $3\sim16pA$ and $0.1\sim0.3V$, respectively. Tribocurrent/voltage build-up was reduced with increasing disk acceleration. Higher humidity conditions $(75\sim80%)$ produced lower levels tribovoltage/current. Therefore, a higher tribocharge is expected at a lower disk acceleration and lower relative humidity condition. Rest time affected the charge build-up at the slider-disk interface. The degree of tribocharge build-up increased with increasing rest time.

Optical Diagnostics for Pulse-discharged Plasma by Marx Generator and Its Application for Modifications of Hemoglobin and Myoglobin Proteins

  • Park, Ji Hoon;Attri, Pankaj;Hong, Young June;Park, Bong Sang;Jeon, Su Nam;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.176.2-176.2
    • /
    • 2013
  • Property of optical diagnostics for pulse-discharged plasma in liquid and its biological applications to proteins are investigated by making use of high voltage Marx generator. The Marx generator has been consisted of 5 stages, where each charging capacitor is 0.5 ${\mu}F$, to generate a high voltage pulse with rising time of $1{\mu}s$. We have applied an input voltage of 6 kV to the each capacitor of 0.5 ${\mu}F$. High voltage pulsed plasma has been generated inside a polycarbonate tube by a single-shot operation, where the breakdown voltage is measured to be 7 kV, current of 1.2 kA, and pulse width of ~ 1 ${\mu}s$ between the two electrodes of anode-cathode whose material is made of tungsten pin, which are immersed into the liquids. We have investigated the emitted hydrogen lines for optical diagnostics of high voltage pulsed plasma. The emission line of 656.3 nm from $H-{\alpha}$ and 486.1 nm from $H-{\beta}$ have been measured by a monochromator. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium conditions, the electron temperature and density of the high voltage pulsed plasma in liquid could be obtained by the Stark broadening of optical emission spectroscopy. For the investigation of the influence of pulsed plasma on biological proteins, we have exposed it onto the proteins such as hemoglobin and myoglobin. The structural changes in these proteins and their analysis have also been obtained by circular dichroism (CD) and ultraviolet (UV) visible spectroscopy.

  • PDF

A Study on the Improved Ignition Limit with Resistor for Propan-air Mixture Gas (저항을 이용한 프로판-공기 혼합가스의 점화한계 개선에 관한 연구)

  • 이춘하;오종용;옥경재;지승욱;이광식;심광렬
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 2004
  • This paper describes the minimum ignition limits for propane-air 5.25 Vol.% mixture gases in low voltage inductive circiuts. The improved effects on the ignition limit are studied by parallel safety components(resistors) for propane-air 5.25 Vol.% mixture gas in low voltage inductive circuits. The experimental devices used in this test are the IEC type spark ignition test apparatus. The minimum ignition limits are controlled by the values of current in inductive circuit. Energy supplied from electric source is first accumulated at the inductance, it's extra energy is working as ignition source of the explosive gas. The improved effects on the ignition limit are respectively obtained as the maximum rising rate of 330% by composing parallel circuits between inductance and resistor as compared with disconnecting inductance with the safety components. The more values of inductance increase the higher improved effects of ignition limit rise. The less values of resistor the higher improved effects of ignition limit rise. It is considered that the result can be used for not only data for researches and development of intrinsically safe explosion-proof machines which are applied equipment and detectors used in dangerous areas but also for datum for its equipment tests.

A Study on Debris Flow Landslide Disasters and Restoration at Inje of Kangwon Province, Korea (2006년 강원도 인제지역의 토석류 산사태 수해 및 복구에 관한 연구)

  • Lee, Cheol-Ju;Yoo, Nam-Jae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.99-105
    • /
    • 2009
  • The main purpose of this work is to analyse damages caused by debris flows during the heavy rainfalls at Inje of Kangwon Province, Korea. A series of site investigations have been carried out to survey the characteristics of debris flows occurred during the summer season of 2006. It has been found that major losses in human life and property are caused by discharge of soil and rock fragments from landslides. During the rainfall high precipitation rate of 113.5 mm/hour and 355 mm/day was recorded, which could happen at 80-500 year period. Comparing the rainfall record with the time of landslides being occurred, occurrence of the landslides is directly related to heavy rainfalls. At present, several debris barriers have been built at the valleys and natural slopes have been protected by the seed spray method. It is intended to propose an alternative of restoration of landslide damages and maintenance based on findings from the current study.

Current Status and Improvements on Management of Plastic Waste in Korea (국내 폐플라스틱의 관리 현황 및 개선사항)

  • Choi, Yong;Choi, Hyeong-Jin;Rhee, Seung-Whee
    • Resources Recycling
    • /
    • v.27 no.4
    • /
    • pp.3-15
    • /
    • 2018
  • Since the use of plastics in various goods such as film, containers, and packaging has been increasing in Korea, the generation of plastic waste is increasing. Plastic wastes are managed by waste charge system, Extended Producer Responsibility (EPR) system and voluntary agreement of plastic waste collection-recycling system. Recently, the management of plastic waste is becoming a social issues due to the refusal of the collection of plastic waste including waste plastic bag and waste vinyl. The ministry of environment in korea was set up the comprehensive plan for recycling waste management in accordance with the circulation cycle of manufacturing and production - distribution and consumption - separate and discharge - collection and sorting - recycling. In this study, the improvements for management of plastic waste were suggested with the review of domestic waste plastics management and the comprehensive plan by the ministry of environment.

Structure of Station Class Lightning Arresters and Electrical Characteristics of ZnO Varistor Blocks (발변전용 피뢰기의 구조 및 ZnO 바리스터 소자의 전기적 특성)

  • Cho, Han-Goo;Han, Se-Won;Lee, Un-Yong;Yoon, Han-Soo;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1158-1161
    • /
    • 2004
  • This paper presents structural characteristics of station class lightning arresters and electrical characteristics of manufactured ZnO varistor blocks which are usable in those arresters. Three types of station class lightning arresters were investigated and those are a ceramic arrester, a FRP tube type polymer arrester, and a FRP rod type polymer arrester. Each arrester has merits and demerits with structural characteristics. In general, polymer arresters were made of silicon rubber for housing materials, FRP tube or rod for mechanical strength, ZnO blocks for electrical characteristics, and metal parts for electrical contact and the silicon rubber, the housing materials, was directly injected to the arrester module which was assembly composed of electrodes, ZnO blocks and FRP tube or rod, and to prevent the nonlinear electric fields distribution on upper parts of arresters, the grade ring was adopted to the upper electrodes. The reference voltage, nonlinear coefficient, residual voltage, and voltage ratio of manufactured ZnO varistors are 4.90kV, 50, 9.54kV, 1.94, respectively. Compared to designed electrical characteristics, the reference voltage was low for 600v and the voltage ratio was slightly high. However, the characteristics of discharge withstand was so excellent that the mechanical destruction does not occur at the impulse current of $8/20{\mu}s$ 10kA for 100 times.

  • PDF

Cathodic Properties of $LiCoO_2$ Synthesized by a Sol-Gel Method for Lithium Ion Battery

  • 조봉준;정의덕;심윤보
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.39-44
    • /
    • 1998
  • $LiCoO_2$ powder was synthesized in an aqueous solution by a sol-gel method and used as a cathode active material for a lithium ion rechargeable battery. The layered $LiCoO_2$ powders were prepared by igniting in air for 12 hrs at 600 ℃ $(600-LiCoO_2)$ and 850 ℃ $(850-LiCoO_2)$. The structure of the $LiCoO_2$ powder was assigned to the space group R bar 3 m (lattice parameters a=2.814 Å and c=14.04Å). The SEM pictures of $600-LiCoO_2$ revealed homogeneous and fine particles of about 1 μm in diameter. Cyclic voltammograms (CVs) of $600-LiCoO_2$ electrode displayed a set of redox peaks at 3.80/4.05 V due to the intercalation/deintercalation of the lithium ions into/out of the $LiCoO_2$ structure. CVs for the $850-LiCoO_2$ electrode had a major set of redox peaks at 3.88/4.13 V, and two small set of redox peaks at 4.18/4.42 V and 4.05/4.25 V due to phase transitions. The initial charge-discharge capacity was 156-132 mAh/g for the $600-LiCoO_2$ electrode and 158-131 mAh/g for the $850-LiCoO_2$ electrode at the current density of 0.2 mA/cm2. The cycleability of the cell consisting of the $600-LiCoO_2$ electrode was better than that of the $850-LiCoO_2$. The diffusion coefficient of the $Li^+$ ion in the $600-LiCoO_2$ electrode was calculated as $4.6{\times}10^{-8}\; cm^2/sec$.

Descriptive Epidemiology of Acute Pyelonephritis in Korea, 2010-2014: Population-based Study

  • Kim, Bongyoung;Myung, Rangmi;Kim, Jieun;Lee, Myoung-jae;Pai, Hyunjoo
    • Journal of Korean Medical Science
    • /
    • v.33 no.49
    • /
    • pp.310.1-310.11
    • /
    • 2018
  • Background: Acute pyelonephritis (APN) is one of the most common community-acquired bacterial infections. Recent increases of antimicrobial resistance in urinary pathogens might have changed the other epidemiologic characteristics of APN. The objective of this study was to describe the current epidemiology of APN in Korea, using the entire population. Methods: From the claims database of the Health Insurance Review and Assessment Service in Korea, the patients with International Classification of Diseases, 10th Revision codes N10 (acute tubulo-interstitial nephritis) or N12 (tubulo-interstitial nephritis, neither acute nor chronic) as the primary discharge diagnosis during 2010-2014 were analyzed, with two or more claims during a 14-day period considered as a single episode. Results: The annual incidence rate of APN per 10,000 persons was 39.1 and was on the increase year to year (35.6 in 2010; 36.7 in 2011; 38.9 in 2012; 40.1 in 2013; 43.8 in 2014, P = 0.004). The increasing trend was observed in both inpatients (P = 0.014) and outpatients (P = 0.004); in both men (P = 0.042) and women (P = 0.003); and those aged under 55 years (P = 0.014) and 55 years or higher (P = 0.003). Eleven times more women were diagnosed and treated with APN than men (men vs. women, 6.5 vs. 71.3), and one of every 4.1 patients was hospitalized (inpatients vs. outpatients, 9.6 vs. 29.4). The recurrence rate was 15.8%, and the median duration from a sporadic episode (i.e., no episode in the preceding 12 months) to the first recurrence was 44 days. The recurrence probability increased with the number of previous recurrences. The average medical cost per inpatient episode was USD 1,144, which was 12.9 times higher than that per outpatient episode (USD 89). Conclusion: The epidemiology of APN in Korea has been changing with an increasing incidence rate.

A study of a present condition of discharge measurement using ADCP in South Korea (ADCP를 이용한 유량측정 현황 분석)

  • Song, Jae Hyun;Kim, Chi Young;Kim, Sam Eun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.448-448
    • /
    • 2016
  • ADCP(Acoustic Doppler Current Profiler)는 유수의 흐름을 방해하지 않으면서 수중에 발사된 음파의 도플러 효과를 이용하여 유속과 유량을 측정하는 장비이다. ADCP는 하천을 횡단하면서 측정하는 장비이기 때문에 기존 유속-면적법에 비해 인력과 시간이 절감된다. 이러한 효율성 때문에 미국, 일본 등 외국뿐 아니라 우리나라에서도 점차 활용이 증가하고 있다. 특히 수위와 유량이 급격하게 변화하여 신속한 측정이 필요한 지점이나, 유속계를 이용한 유량측정이 곤란한 대하천에서 널리 사용되고 있다. ADCP는 미국을 중심으로 1980년대 말부터 하천 유량 측정에 도입된 후 여러 해 동안 현장에서의 적용성 평가가 이루어져 왔으며, 점차 적용이 확대되고 있는 실정이다. 국내에서도 1990년대 후반부터 ADCP가 도입되기 시작하여, 유량측정 기법 및 국내 하천에의 적용성에 대한 검토가 진행되어 왔으며, ADCP를 이용한 유량측정의 빈도와 활용범위가 점차 증가하고 있다. 국토교통부의 유량측정을 전담하고 있는 유량조사사업단의 2009년~2014년 측정장비별 측정성과를 살펴보면, 2009년 7.8%였던 ADCP 사용률은 2014년 27.8%로 약 3배 이상 증가하였으며, 2010년~2011년 4대강 공사로 인하여 사용률이 높아진 후, 2013년부터 본격적으로 사용된 것을 알 수 있다. ADCP뿐만 아니라 FlowTracker 역시 저유속 유량측정을 대체하고 있으며, 2009년 10.9%였던 FlowTraker와 ADCP 측정성과는 2014년 전체 측정성과의 56.2%를 차지하며, 기계식 유속계와 부자 측정성과를 넘어서고 있다. 홍수기(7월~8월) 측정성과를 살펴보면, 2009년 9.3%였던 ADCP 사용률은 2014년 31.8%로 전체 측정성과와 유사한 증가폭을 나타냈으며, 2012년 이후 사용률이 급증하고 있는 것을 알 수 있다. 본 연구에서는 국내 유량측정 사업에 사용률이 급격하게 증가하고 있는 ADCP의 활용 현황 및 문제점 등을 분석하여 향후 ADCP를 이용한 유속 및 유량측정의 체계적인 활용 및 측정기법의 개선에 활용하고자 한다.

  • PDF