• Title/Summary/Keyword: Discharge Time

Search Result 2,626, Processing Time 0.034 seconds

Experiments on the GPR Reposnse of the Organic Hydrocarbons (유류오염물질의 GPR 반응에 대한 모델 실험 연구)

  • 김창렬
    • Economic and Environmental Geology
    • /
    • v.37 no.2
    • /
    • pp.185-193
    • /
    • 2004
  • A physical model experiment was conducted using a sand and gravel-filled tank model, to investigate the influence on the GPR response of LNAPL vapor phase effects in the unsaturated zone and of residual phase of LNAPL trapped in the saturated zone. Background measurements of GPR were made with only water in the tank using a fluctuating water table model. Gasoline was, then, injected into the bottom of the model tank to simulate a subsurface discharge from a leaking pipe or tank at depth, obtaining GPR data with rising and lowering of water table. Results from the experiment show the GPR sensitivity to the changes in the moisture content in the vadose zone and its effectiveness for monitoring minor fluctuation of the water table. The results also demonstrate a potential of GPR for monitoring possible vapor phase effects of volatile hydrocarbons in the vadose zone as a function of time, and for detecting the effects of residual phase of hydrocarbons in the water saturated system. In addition, the results provide the basis for a strategy that has the potential to successfully detect and delineate residual LNAPL contamination in the water-saturated system at field sites where the conditions are similar to those simulated in the physcial models described herein.

Numerical Simulations of Water Quality in ManKyong River (QUAL-II E 모델에 의(依)한 만경강(萬頃江)의 수질예측(水質豫測))

  • Shim, Jae-Hwan;Choi, Moon-Sul
    • Korean Journal of Environmental Agriculture
    • /
    • v.10 no.1
    • /
    • pp.67-75
    • /
    • 1991
  • The QUAL-II E Model was applied to predict the water quality of the Mankyong drainage System, and lead to following conclusion. 1. The difference between computed and measured BOD at the M-3 (Bakgugeong) station was within 10%, indicating that the application of the QUAL-IIE Model for the prediction of water quality was satisfactory thus far. 2. The application of the model states that the discharge of concentrated pollutants at the M-1 station on the Jeonju stream, located 41Km upstream from the estuary, causes the worst problems. The sluice which extends residence time and enlarges watery surface improves water quality by a Self-purification process at the M-3 station, 28km upstream from the estuary. 3. The accuracy of the model diminished when this model was applied on the estuary downstream of the sluice. Hence, the application of the model on the estuary needs to be used with caution. 4. Among the conputed water quality parameters, BOD is the worst problem. At the M-3 station, BOD is computed to be 26.6 mg/1 in 1996, 30.7 mg/1 in 2,001, 33.0 mg/l in 2006, and 37.5 mg/1 in 2011. When preventive measures against water pollution are not properly exercised, severe problems in irrigation and water resources are expected. This study will be of used in the selection of irrigation water intake points, the criteria of effluent treatment, the management of water resources, and the establishment of water quality managemont policy.

  • PDF

Assessment of Biological Toxicity Monitoring in Water Using Sulfur Oxidizing Bacteria (하천수의 생태독성을 파악하기 위한 황산화미생물의 이용가능성 평가)

  • Kang, Woo-Chang;Oh, Sang-Eun
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.2
    • /
    • pp.170-174
    • /
    • 2012
  • BACKGROUND: Inappropriate discharge of wastewaters and industrial effluents are becoming detrimental to the aquatic environment. The presence of toxic substances on wastewaters can be detected by physicochemical and biological methods. However, physicochemical methods do not give any information about biological toxicity. Therefore, in this study we tried to detect the presence of toxic substance on waters using sulfur-oxidizing bacteria (SOB) as a bioassay. MATERIALS AND RESULTS: The SOB biosensor was first stabilized using synthetic stream water and operated in both continuous and semi-continuous mode. When the SOB biosensor was operated in continuous mode, the effluent electrical conductivity (EC) stabilized at~1.72 dS/m. While in the case of semi-continuous, the EC stabilized at~0.6 dS/m. The SOB system was also operated at different reaction times to ascertain the shortest reaction time for monitoring the toxicity. Finally, the SOB biosensor was fed with nitrite as toxic substance. When 5 mg/L of nitrite was added to the SOB system, the EC decreased immediately. However, the EC recovered after few cycle. CONCLUSION: This study shows that the SOB biosensor can be used as warning system to protect aquatic environment from hazardous materials. Although SOB biosensor can not give specific information about the toxic substances, it can assess whether the water is toxic or not.

Electrochemical Performances of Acid-Treated and Pyrolyzed Cokes According to Acid Treatment Time (산처리 시간별 산화 코크스와 열분해 코크스의 전기화학적 거동)

  • Kim, Ick-Jun;Yang, Sunhye;Jeon, Min-Je;Moon, Seong-In;Kim, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.407-412
    • /
    • 2008
  • As an activation procedure, in this study, the oxidation treatment of needle cokes with a dilute nitric acid and sodium chlorate $(NaClO_3)$, combined with heat treatment, was attempted. The structures of acid-treated and pyrolyzed coke were examined with XRD, FESEM, elemental analyzer, BET, and Raman spectroscopy. The behavior of double layer capacitance was investigated with the analysis of charge and discharge. The structure of needle coke treated with acid was revealed to a single phase of (001) diffraction peak after 24 h. On the other hand, thecoke oxidized by heat treatment was reduced to a graphite structure of (002) at $300^{\circ}C$. The distorted graphene layer structure, derived from the process of oxidation and reduction of the inter-layer, makes the pores by the electric field activation at the first charge, and generates the double layer capacitance from the second charge. The cell using pyrolyzed coke with 24 h acid treatment and $300^{\circ}C$ heat treatment exhibited the maximum capacitance per weight and volume of 33 F/g and 30 F/mL at the two-electrode system in the potential range of 0~2.5 V.

Activities of a Home Hospice Organization (가정호스피스기관의 활동에 관한 연구)

  • Kim, Jung-Hee;Choi, Young-Soon
    • Journal of Hospice and Palliative Care
    • /
    • v.3 no.1
    • /
    • pp.28-38
    • /
    • 2000
  • Purpose : This study examined characteristics of, problems of and services provided to hospice recipients and their family members at a home hospice organization. Methods : The subjects were 113 people who were discharged from one free-standing home hospice organization between November, 1994 and lune, 1999. Since the opening of the organization in November of 1994, it has provided hospice services at patients' homes with no charge. Data were collected from those subjects' records. Results : The average age of the subjects was 57.1 years; those aged 60 and over were 54%. Spouse was the most frequent(50.9%) primary caregiver followed by daughter-in-law and daughter. All the subjects were diagnosed as having cancer. Of those 41 subjects who did not know their terminal stage in the beginning, 31 subjects came to know their states. Of the subjects, 72.7% were referred from their physicians. On the average, the service duration and the number of home visits were 6.8 weeks and 7.2 times, respectively. Pain was the most prevalent problem of the subjects(89.4%). Medication management was the most frequently provided service followed by psychological supports. The reasons for discharge were death(88.5%) and refusal(8%). Home was the most frequent place of death(60%). Conclusion Home hospice service providers should be trained particularly in working with elders and in managing cancer pain. People need to be referred at an appropriate time for achieving goals of hospice. Community recognition of hospice services needs to be promoted.

  • PDF

Assessment for the Possibility of Water-ecosystem Restoration Applying LID Techniques in the Deokjin Park Area, Jeonju City (LID기법을 이용한 전주 덕진공원의 수생태 복원 가능성 평가)

  • Choi, Seung-Hyun;Kim, Seok-Hwi;Kim, Kangjoo
    • Economic and Environmental Geology
    • /
    • v.48 no.6
    • /
    • pp.477-490
    • /
    • 2015
  • In this study, we investigated the restoration possibility of the old streams by enhancing the rainwater infiltration in the watershed of Deokjin Park, Jeonju City. This study was performed by modeling groundwater discharge to the streams under various conditions. We assessed the amount and location of groundwater recharge enhancement to restore the streams and evaluated whether the baseflows of the restored streams are sufficient to keep the water ecosystem of the Deokjin Pond. The results show that the baseflow of the streams can persist for a longer time even during the dry season when the rainwater drainage system is recovered similarly to the those before development using low impact development (LID) techniques. The enhancements of recharge in the headwater area, which is the area around the zoo and Daeji Village in the Deokjin Park watershed, is useful to increase the baseflows of the downstream reaches. Furthermore, spreaded recharge over a widespread area is better to prevent the streams from drying than the intensive recharge at a few sites.

Water Quality Improvement Using a Contact Oxidation Canal with Sedimentation Basin (침전접촉산화수로를 이용한 수질 개선)

  • Kim, Won-Jang;Park, Sang-Hyun;Kim, Hyung-Joong;Kim, Tae-Kyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.3
    • /
    • pp.143-149
    • /
    • 2001
  • A contact oxidation canal system with sedimentation basin was installed to study the efficiency of water quality purification. The primary sedimentation basin with 60 min of HRT (Hydraulic Retention Time) included in the system was aimed to sediment pollutants in the water and the deposit being released by the drainage culvert located at the bottom of the system. The oxidation canal aerated by nozzle was to contact the pollutants and oxygen in the surface of plastic filter to purify the water. Discharge, HRT, length of the oxidation canal were $200\;m^3/day$, 90 min, 20 m, respectively. The treatment efficiency of total nitrogen was lower compared with other water quality items such as SS, BOD, TP because the anoxic condition for denitrification was not ensured after the oxidation canal. However, $25%{\sim}89.6%$ of SS, $75.0%{\sim}91.5%$ of BOD, $44.3%{\sim}95.3%$ of TP were removed in this system. Overall, the results indicates that this system appears to have a potential capability for water quality improvement of the reservoirs or the canals in the agricultural watershed.

  • PDF

Histological study of neurosecretory cells in the brain and the thoracic ganglion with gonadal development of Palaemon serrifer (줄새우아재비, Palaemon serrifer의 생식소발달에 따른 뇌와 흉부신경절 신경분비세포의 조직학적 연구)

  • KIM Myung-Hee;LEE Taek-Yuil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.24 no.5
    • /
    • pp.327-339
    • /
    • 1991
  • The present paper is a histological study of neurosecretory cells in the brain and the thoracic ganglion with the gonadal development in Palaemon serrifer. The reproductive cycle includes the successive stages of the growing period (February-March), the mature period(April-May), the ripe and spent periods(June-August) and the degenerative and resting periods(September-January). The neurosecretory cells are grouped into four types based on Matsumoto(1958) : A-,A'-, B- and E-cells. A- and A'-cells are $80-90{\mu}m,\;B-cell\;is\;30-40{\mu}m$ and E-cell is $10-15{\mu}m$. A- and B-cells are the positive to CHP and AF, while B-cell is the positive only to AF. The secretory grannules of a A-cell are transported to the axon, and at the same time they are discharged through the peripheral membrane. Of the four neurosecretory cells, A- and I-cells show the difference of secretory activity according to the gonad developmental process. In the female, A-cells show secretory activity for the ripe and spent periods, while I-cells show for the mature, ripe and spent periods. In the male, A-cells show secretory activity for the mature, ripe and spent periods, while I-cells show for the growing, mature, ripe and spent periods.

  • PDF

Bronchoscopic Ethanolamine Injection Therapy in Patients with Persistent Air Leak from Chest Tube Drainage

  • Lim, Ah-Leum;Kim, Cheol-Hong;Hwang, Yong-Il;Lee, Chang-Youl;Choi, Jeong-Hee;Shin, Tae-Rim;Park, Yong-Bum;Jang, Seung-Hun;Park, Sang-Myeon;Kim, Dong-Gyu;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck;Shin, Ho-Seung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.5
    • /
    • pp.441-447
    • /
    • 2012
  • Background: Chest tube drainage (CTD) is an indication for the treatment of pneumothorax, hemothroax and is used after a thoracic surgery. But, in the case of incomplete lung expansion, and/or persistent air leak from CTD, medical or surgical thoracoscopy or, if that is unavailable, limited thoracotomy, should be considered. We evaluate the efficacy of bronchoscopic injection of ethanolamine to control the persistent air leak in patients with CTD. Methods: Patients who had persistent or prolonged air leak from CTD were included, consecutively. We directly injected 1.0 mL solution of 5% ethanolamine oleate into a subsegmental or its distal bronchus, where it is a probable air leakage site, 1 to 21 times using an injection needle through a fiberoptic bronchoscope. Results: A total of 15 patients were enrolled; 14 cases of spontaneous pneumothorax [idiopathic 9, chronic obstructive pulmonary disease (COPD) 3, post-tuberculosis 2] and one case of empyema associated with broncho-pleural fistula. Of these, five were patients with persistent air leak from CTD, just after a surgical therapy, wedge resection with plication for blebs or bullae. With an ethanolamine injection therapy, 12 were successful but three (idiopathic, COPD and post-tuberculosis) failed, and were followed by a surgery (2 cases) or pleurodesis (1 case). Some adverse reactions, such as fever, chest pain and increased radiographic opacities occurred transiently, but resolved without any further events. With success, the time from the procedure to discharge was about 3 days (median). Conclusion: Bronchoscopic ethanolamine injection therapy may be partially useful in controlling air leakage, and reducing the hospital stay in patients with persistent air leak from CTD.

A Study on Parameters Estimation of Storage Function Model Using the Genetic Algorithms (유전자 알고리듬을 이용한 저류함수모형의 매개변수 추정에 관한 연구)

  • Park, Bong-Jin;Cha, Hyeong-Seon;Kim, Ju-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.4
    • /
    • pp.347-355
    • /
    • 1997
  • In this study, the applicability of genetic algorithms into the parameter estimation of storage function method for flood routing model is investigated. Genetic algorithm is mathematically established theory based on the process of Darwinian natural selection and survival of fittest. It can be represented as a kind of search algorithms for optima point in solution space and make a reach on optimal solutions through performance improvement of assumed model by applying the natural selection of life as mechanical learning province. Flood events recorded in the Daechung dam are selected and used for the parameter estimation and verification of the proposed parameter estimation method by the split sample method. The results are analyzed that the performance of the model are improved including peak discharge and time to peak and shown that the parameter Rsa, and f1 are most sensitive to storage function model. Based on the analysis for estimated parameters and the comparison with the results from experimental equations, the applicability of genetic algorithm is verified and the improvements of those equations will be used for the augmentation of flood control efficiency.

  • PDF