• Title/Summary/Keyword: Discharge Ratio

Search Result 1,054, Processing Time 0.027 seconds

A study on the by-pass valve design of a scroll compressor with asymmetric wrap (비대칭 랩 스크롤 압축기의 바이패스 밸브 설계에 관한 연구)

  • 최진섭;곽상호;김현진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.181-189
    • /
    • 2000
  • The scroll compressor used for heat pump has a wide range of operation condition. To cover both heating and cooling modes, the operating Pressure ratio ranges from 1.5 to 6.8. Since the scroll compressor, however, is a type of compressor whose pressure ratio is fixed, some loss in the compression work is caused by the operation at the pressure ratio different from the built-in pressure ratio. A way of avoiding this problem is to introduce by-Pass holes in compression chambers, so that the compressed gas of pressure higher than the discharge pressure, yet not reached to the discharge port can be released earlier through the by-Pass holes. In this paper, an optimum Positioning of the by-Pass hole and the effect of the by-pass valve on the compressor performance are studied.

  • PDF

A.C Breakdown Characteristics in ${SF}_{6}$ in the Presence of A Small Discharge (미소 방전존재시의 ${SF}_{6}$에 대한 교류절연 파괴 특성)

  • 이광식;이동인;김인식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.3
    • /
    • pp.321-328
    • /
    • 1990
  • The effect of a small discharge on the A.C (60Hz) breakdown characteristics in SF6 gas has been studied. Various experiments were investigated while varying distance of the rod-plane electrode, the gas pressure, and the magnitude of the small discharge current. Also, the position of the discharge path was observed for the purpose of evident investigation. As the results of this study, authors clarified the shifting mechanism of the position of discharge path with the ratio Rn (E/N distribution at a certain higher tempera-ture due to the small discharge current to E/N distribution at room temperature, E:electric field strength, N:particle number density). Also, the reason for the reduction of the A.C. breakdown voltage was investigated in the presence of a small discharge current.

  • PDF

High Rate Performance of Li[Co0.50Li0.17Mn0.33]O2 Cathode (Li[Co0.50Li0.17Mn0.33]O2 양극물질의 고율 충방전 특성)

  • Park Yong-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.8
    • /
    • pp.737-743
    • /
    • 2006
  • [ $Li[Co_{0.50}Li_{0.17}Mn_{0.33}]O_2$ ] powder was prepared using a simple combustion method. specially, ratio of 2:1, 3:2, 1:1, 2:3, 1:2 was adopted as acetate source/nitrate source. The diffraction pattern of $Li[Co_{0.50}Li_{0.17}Mn_{0.33}]O_2$ powder showed that this compound could be classified as hexagonal $a-NaFeO_2$ structure (space group : $R\bar{3}m$). The size of powder was less than $1{\mu}m$. Small particle size of cathode powder would give a good ionic and electronic conductivity to cathode electrode, which made of cathode powder. As the increase of nitrate source-ratio, discharge capacity of $Li[Co_{0.50}Li_{0.17}Mn_{0.33}]O_2$ at high charge-discharge rate was increased. When the ratio of acetate source/nitrate source was 1:2, discharge capacity at 10 C rate (2000 mA/g) was 180 mAh/g. It was $10{\sim}15%$ larger than that of powder, which have 2:1 as acetate source/nitrate ratio.

Experimental Parametric Study on the Rotordynamic Characteristics and Optimal Design of a Flexible Rotor Supported by a Slotted-Ring Electro-Rheological Squeeze Film Damper (슬롯 링 형상을 갖는 전기 유변 스퀴즈 필름 댐퍼로 지지된 연성 로터의 동특성 및 최적설계 파라미터 실험 연구)

  • 이용복;김창호;이남수;최동훈;정시영
    • Tribology and Lubricants
    • /
    • v.16 no.3
    • /
    • pp.157-165
    • /
    • 2000
  • A discharge free Electro-Rheological Squeeze Film Damper (ER-SFD) with predetermined-clearances at leakage ends can inherently eliminate electric discharge problems while still supplying stable leakage control. Test results show that the damping force of the slotted-ring ER-SFD is mainly affected by electric voltage, oil supply pressure, position of the damper and ratio of effective surface area of slotted-rings. As the supply voltage is larger, the amplitudes of both slotted ER-SFD and rotor are decreased at first and second critical speeds. The influence of the oil supply pressure and the effective surface area ratio was shown mainly near the first critical speed. The effective surface area ratio of slotted-rings influences the reduction of flexible rotor vibration. As a result, experimental results confirm that the slotted-ring ER-SFD satisfactorily controls the flexible rotor vibration, while eliminates the inherent electric discharge problems in conventional ER-SFDs.

Development and Evaluation of Sediment Delivery Ratio Equation using Clustering Methods for Estimation of Sediment Discharge on Ungauged Basins in Korea (국내 미계측 유역의 유사유출량 예측을 위한 군집별 유사전달율 산정식 도출 및 평가)

  • Lee, Seoro;Park, Sang Deog;Shin, Seung Sook;Kim, Ki-sung;Kim, Jonggun;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.537-547
    • /
    • 2018
  • Sediment discharge by rainfall runoff affects water quality in rivers such as turbid water, eutrophication. In order to solve various problems caused by soil loss, it is important to establish a sediment management plan for watersheds and rivers in advance. However, there is a lack of sediment data available for estimating sediment discharge in ungauged basins.. Thus, reasonable research is very important to evaluate and predict the sediment discharge quantitatively. In this study, cluster analysis was conducted to classify gauged watersheds into hydrologically homogeneous groups based on the watershed characteristics. Also, this study suggests a method to efficiently predict the sediment discharge for ungauged basins by developing and evaluating the SDR equations based on the PA-SDR module. As the result, the SDR equations for the classified watersheds were derived to predict the most reasonable sediment discharge of ungauged basins with 0.24 % ~ 10.89 % errors. It was found that the optimal parameters for the gauged basins reflect well characteristic of sediment movement. SDR equations proposed in this study will be available for estimating sediment discharge on ungauged basins. Also it is possible to utilize establishing the appropriate sediment management plan for integrated management of watershed and river in Korea.

A Multilevel Analysis about the Impact of Patient's Willingness for Discharge on Successful Discharge from Long-term Care Hospitals (퇴원 의지가 요양병원의 성공적 퇴원에 미치는 영향에 대한 다수준 분석)

  • Ghang, Haryeom;Lee, Yeonju
    • Health Policy and Management
    • /
    • v.32 no.4
    • /
    • pp.347-355
    • /
    • 2022
  • Background: Since November 2019, long-term care hospitals have been able to provide patients with discharging programs to support the elderly in the community. This study aimed to identify both patient- and hospital-level factors that affect successful community discharge from long-term care hospitals. Methods: A multilevel logistic regression model was performed using hospitals as a clustering unit. The dependent variable was whether a patient stayed in the community for at least 30 days after discharge from a long-term care hospital. As for the patient-level independent variables, an agreement between a patient and the family about discharge, length of hospital stay, patient category, and residence at discharge were included. The number of beds and the ratio of long-stay patients were selected for the hospital-level factors. The sample size was 1,428 patients enrolled in the discharging program from November 2019 to December 2020. Results: The number of patients who were discharged to the community and stayed at least for 30 days was 532 (37.3%). The intraclass correlation coefficient was 22.9%, indicating that hospital-level factors had a significant impact on successful community discharge. The odds ratio (OR) of successful community discharge increased by 1.842 times when the patients and their families agreed on discharge. The ORs also increased by 3.020 or 2.681 times, respectively when the patients planned to discharge to their own house or their child's house compared to those who didn't have a plan for residence at discharge. The ORs increased by 1.922 or 2.250 times when the hospitals were owned by corporate or private property compared to publicly owned hospitals. The ORs decreased by 0.602 or 0.520 times when the hospital was sized over 400 beds or located in small and medium-sized cities compared to less than 200 bedded hospitals or located in metropolitan cities. Conclusion: The results of the study showed that the patients' and their family's willingness for discharge had a great impact on successful community discharge and the hospital-level factors played a significant role in it. Therefore, it is important to acknowledge and support long-term care hospitals to involve active in the patient discharge planning process.

Discharge Patterns of Yongnup, Daeam-san (대암산 용늪의 유출 패턴에 관한 연구)

  • ZHU, Ju-Hua;PARK, Jongkwan
    • Journal of The Geomorphological Association of Korea
    • /
    • v.18 no.4
    • /
    • pp.271-282
    • /
    • 2011
  • The purpose of this study is to clarify the discharge patterns of Yongnup, Daeam-san. Many hydrographs were analyzed by the types of rising and falling stages, and the slope of those stages with the semi-log graph paper was a key point to distinguish the discharge patterns during rainstorms. The correlation between rainfall intensity and slopes of the second or third rising stage was higher than that between slopes of the first rising stage and rainfall intensity. Also, the coefficient of correlation between discharge decrement and the lapsed time from the peak to inflection point of hydrograph, during high water stages, was better than that during low water stages. The annual average discharge rate of Yongnup was 0.54 and the average direct runoff ratio was 0.14. The total discharge amount from Yongnup was about 410,000 tons for a water year, the monthly maximum amount emerged in September and the minimum amount was occurred in March. In summer, 37.7% was a seasonal maximum runoff ratio; on the other hand, 9.4% was a seasonal minimum runoff ratio in winter.

A study for its Characteristics with Electric Variation in an Electrical Discharge Machining (방전가공에서 전기적 변화가 갖는 방전 특성에 관한 연구)

  • 신근하
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.03a
    • /
    • pp.132-136
    • /
    • 1996
  • A Study is a experiment which is figure out to aptimum discharge cutting condition of the surfaceroughness, electric discharging speed and electro wear ratio with Ton Toff and V(voltage) as an input condition according to the current(Ip) in an electric spark machine ; 1)Electrode is utilized Cu(coper) and Graphite. 2)Work piece is used the material of carbon steel. The condition of experiment is; 1)Current is varied 0.7(A) to 50(A). 2)Pulse time(Ton) is varied 3($\mu$s) to 240($\mu$s) and also Toff is varied 7($\mu$s) to 20($\mu$s). 3)The time of electric discharging to work piece in each time is 30(min) to 60(min) 4)After the upper side of work piece was measured in radius (5${\mu}{\textrm}{m}$) of syulus analyzed the surface roughness to made the table and graph of Rmax by yielding data. 5)Electro wear ratio is; \circled1Coper was measured cx-machining and post machining but the electronic baiance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume specific gravity and analyzed to made its table and graph on ground the data 6)In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V.R(Automatic Voltage Regulator). 7)The memory scope was sticked to the electric spark machine. 8)In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid, it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging According to above results, the surface roughness by the variation of electrodw and current was analyzed to compare KS(Korea Standards) It was decided the optimum condition of electric discharge cutting through analyzing the effect of electric discharge speed and electro wear ratio.

  • PDF

An Experimental Study of Discharge Coefficient with Non-Circular Effervescent Type Twin-fluid Nozzle (비원형 Effervescent Type 이유체노즐의 Discharge Coefficient에 관한 실험적 연구)

  • Lee, Sang Ji;Park, Hyung Sun;Hong, Jung Goo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.682-685
    • /
    • 2017
  • An experimental study was carried out to investigate the injection characteristics of non-circular effervescent type twin-fluid nozzles. For this purpose, two types of non-circular nozzles (E1, E2) and one kind of circular nozzle (C) were used. At this time, the Aerorator mounted on the nozzle used three different diameters to match the aspect ratio with the nozzle exit area. Therefore, experiments were performed according to three aspect ratios for each nozzle, and a total experiments were conducted. Experiments were carried out by controlling the amount of air flowing after fixing the flow rate of the liquid, and the nozzle internal pressure and SMD were measured, and the jet image was taken from the nozzle. The discharge coefficients of the three kinds of nozzles were compared with the conventional equation and the Jedelsky's equation, and the Jedelsky's equation was found to be about 4 times larger. The droplet size (SMD) injected from the nozzle was found to be smaller in the non-circular shape than in the circular shape, which is expected to be caused by the difference of the discharge coefficient values.

  • PDF

The Effect of Pressurized Hydrogen on the Aging and Partial Discharge Activity in Generator Winding Insulations (가압 수소가 발전기 고정자 권선 절연 열화와 부분 방전 특성에 미치는 영향)

  • 김진봉
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.100-107
    • /
    • 1999
  • The purpose of the study is to investigate the effect of H$_2$ pressure on partial discharge (PD) activity and aging rate in turbine generator winding insulations. A series of field tests and laboratory tests were peformed to investigate the effect of $H_2$ pressure on PD activity. Field tests were conducted at two unit turbine generators in two conditions, in $H_2$ pressure and in air atmosphere. Obtained results are as follows ; 1) ${\Delta}tan{\delta}$ and maximum partial discharge are reduced with increase of $H_2$ pressure and partial discharge inception voltage. 2) The reduction ratio of ${\Delta}tan{\delta}$ due to $H_2$ pressure is higher than one of PD magnitude. 3) Partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. From the result, partial discharge pulses are subjected to resonance phenomena in a generator winding.

  • PDF