• Title/Summary/Keyword: Discharge Ratio

Search Result 1,064, Processing Time 0.026 seconds

A Study of The Surface Dielectric Barrier Discharge Design Conditions for Generating Negative Air Ions (음이온 생성을 위한 표면 유전체장벽방전의 설계조건 연구)

  • Shin, Sang-Moon;Kim, Jung-Yoon;Kim, Jong-Soo;Choi, Jae-Ha;Choi, Won-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.114-122
    • /
    • 2014
  • This paper describes a study of the design conditions of a planar surface dielectric barrier discharge (DBD) reactors for generating negative air ions. The capacity of negative air ion generated by the surface DBD reactor is affected by the shape, area ratio and the location of the discharge and induction electrodes of it. To study the optimal design conditions of DBD reactors, the electrodes printed on the substrate of a PCB board is utilized to conduct kind of experiments: the distance of the each electrode along with the X-Y axis, the area ratio of the discharge electrode to induction electrode, and the symmetrical and asymmetrical location of two electrodes. The ion generation capacity is inverse proportional to the gap increases along with X-Y axis. And the optimum ion concentration generated by the ionizer was inspected when the electrodes area ratio was 3 and 5 times of the symmetrical and asymmetrical experimental condition respectively.

The Effect of Rolling on the Charge-Discharge Characteristic of Metal Hydride Electrode for Ni-MH Secondary Battery (압연이 Ni-MH 2차전지용 금속수소화물 전극의 충·방전 특성에 미치는 영향)

  • Park, Won;Chang, Sang-Min;Choi, Seung-Jun;Noh, Hak;Choi, Jeon;Park, Choong-Nyeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.7 no.2
    • /
    • pp.165-171
    • /
    • 1996
  • The effect of rolling on the charge-discharge property was studied for metal hydride negative electrode. $(LM)Ni_{3.6}Al_{0.4}Co_{0.7}Mn_{0.3}$(pleateau pressure : below 1 atm at room temperature, volume expansion : 9%, entalpy : $8.7kcal/molH_2$) alloy was prepared by arc melting, and then it was coated with various copper weight percent. The copper coated alloys were then rolled with the different reduction ratio. From the results, it was found that the maximum discharge capacity increased with increasing reduction ratio, and 15wt% copper coated sample shows the highest discharge capacity, 324mAh/g, after rolling with 30% reduction ratio. In view of cycle life for the negative electrode, the 15wt% copper coated electrode which was rolled with 13% reduction ratio showed the longest cycle life compared with other electrodes.

  • PDF

Pollutant Delivery Ratio of Okdong-cheon Watershed Using HSPF Model (HSPF 모형을 이용한 옥동천 유역의 유달율 분석)

  • Lee, Hyunji;Kim, Kyeung;Song, Jung-Hun;Lee, Do Gil;Rhee, Han-pil;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.1
    • /
    • pp.9-20
    • /
    • 2019
  • The primary objective of this study was to analyze the delivery ratio using Hydrological Simulation Program - Fortran (HSPF) in Okdong-cheon watershed. Model parameters related to hydrology and water quality were calibrated and validated by comparing model predictions with the 8-day interval filed data collected for ten years from the Korea Ministry of Environment. The results indicated that hydrology and water quality parameters appeared to be reasonably comparable to the field data. The pollutant delivery loads of the watershed in 2015 were simulated using the HSPF model. The delivery ratios of each subwatershed were also estimated by the simple ratio calculation of pollutant discharge load and pollutant delivery load. Coefficients of the regression equation between the delivery ratio and specific discharge were also computed using the delivery ratio. Based on the results, multiple regression analysis was performed using the discharge and the physical characteristics of the subwatershed such as the area. The equation of delivery ratio derived in this study is only for the Okdong-cheon watershed, so the larger studies are needed to apply the findings to other watersheds.

A Computational Study for the Discharge Coefficient of a Film-Cooling Hole (Film-Cooling Hole의 유출계수에 관한 수치해석적 연구)

  • 김재형;김희동;박경암
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.2
    • /
    • pp.15-22
    • /
    • 2003
  • Computational study using the 2-dimensional, compressible, Navier-Stokes equations is performed to predict the discharge coefficient of air flow through a film-cooling hole. In order to investigate the effect of internal/external flows on discharge coefficient, the present computational results which are obtained for three flow cases, only external flow, only internal flow, and no flow, are compared with experimental ones. It is found that the computational results predict the discharge coefficient of the film-cooling hole in a reasonable accuracy and the external crossflow reduces the discharge coefficient, while the internal crossflow increases the discharge coefficient in a range of momentum flux ratio $I_{c-jet}$ > 1 due to the total pressure loss and boundary layer effect.

A Study on the Discharge AND Gate of Plasma Display Panels (플라즈마 디스플레이 패널의 방선 AND gate에 간한 연구)

  • 손현성;채승엽;염정덕
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.39-46
    • /
    • 2001
  • The plasma display panel with the electrode structure of new discharge AND gate was developed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the imput discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore, it is possible to apply to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning electrical discharge does not influence the picture quality.

  • PDF

Numerical analysis of flow characteristics at the bifurcation channel by changing of discharge ratio using TELEMAC-2D (TELEMAC-2D를 적용한 개수로 분류부 유량비 변화에 의한 흐름특성 분석)

  • Jung, Daejin;Jang, Chang-Lae;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • This study investigates the flow characteristics, such as velocity distributions, size and location of recirculation zone, longitudinal flow change rates, and bifurcation discharge ratio in the bifurcation channel by TELEMAC-2D, a 2D numerical model. The numerical model is validated by previous experimental results and the numerical results are in relatively good agreement with the experimental results, such as the water surface elevation and velocity distribution in the channels. As the inertial force and moment in the main channel decrease, the bifurcation discharge ratio increases, and the relative high velocity distribution becomes wider and the reverse velocity of the main stream decreases in the branch channel. As the bifurcation discharge ratio increases, the size of the recirculation zone in the branch channel decreases and it can be more clearly calculated by determining the point where the longitudinal froude number $Fr{\approx}0$ as well as drawing the distribution of the streamline distribution.

A Study on Discharge Estimation by Representative Parameter Method in Open Channels (개수로에서의 대표 매개변수 방법에 의한 유량산정에 관한 연구)

  • Choo, Tai Ho;Chae, Soo Kwon
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.637-644
    • /
    • 2012
  • The discharge estimation that means the most important element in a wetlands ecosystem and rivers is a prime concern. All the interim, this discharge estimation depends on stage-discharge curve, but the limitation of stage-discharge curve that uses only connection between the stage and discharge is widely well known. Thus, this paper proposed a method of discharge estimation in a section through "representative parameter estimation method" by using Manning and Chezy equations that have been extensively used in an open channel. Each result is presented by both RMSE and Discrepancy Ratio. The scale difference for the results between laboratory and natural open channel data existed, but the each result showed that the estimated discharge agree with the measured discharge. If the verification and improvement are conducted in various rivers through continuous study, the easy and rapid discharge estimation will be possible. So, the proposed method will be utilized in the water resources fields.

A study on the discharge ratio of two solutions with different viscosities using computational fluid analysis (전산유체해석을 이용한 점도가 다른 이종 용액의 토출 비율 연구)

  • Ko, Min-Sung;Wi, Eun-Chan;Yun, Yi-Seob;Kong, Jung-Shik;Lee, Joong-Bae;Kim, Min-Su;Baek, Seung-Yub
    • Design & Manufacturing
    • /
    • v.15 no.4
    • /
    • pp.43-50
    • /
    • 2021
  • Pump-cap is a device for discharging the contents stored inside a container to the outside of the container by a simple operation by a certain amount. In particular, in recent years, as the number of cosmetic products made of functional materials has rapidly increased, the development of convenient containers for functional materials is being actively conducted. Among these, there are a growing number of products that show their efficacy only by mixing two components, so the development of a dual pump cap container is necessary. However, the conventional dual pump cap container has a problem in that it is difficult to implement a quantitative discharge as solutions having different viscosities are used. Therefore, in this study, a discharge port of a dual pump cap that can apply an optimal ratio was designed by analyzing the discharge amount of two components with different viscosities through computational fluid dynamics. Since the discharge amount is affected by the size of the discharge port, the higher the viscosity of the solution, the larger the discharge port should be set. Conversely, the lower the viscosity, the smaller the discharge port should be. Through this, it is possible to dispense a fixed amount of a heterogeneous solution by one pumping, and it is determined that the user's convenience will increase.

A study on Discharge Characteristics of Rotating Discharge Hole with inlet edge shape (입구 형상에 따른 회전 송출공의 송출특성 연구)

  • Kang, Se-Won;Ha, Kyung-Pyo;Kauh, S.-Ken
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.746-752
    • /
    • 2000
  • A study on discharge characteristics of a rotating discharge hole is very important to enhance the performance of an induction motor which have external forced cooling system. The discharge characteristics of rotating discharge holes are influenced by rotating speed, length-to-diameter ratio, inlet shape of rotor holes, etc. An experimental study on the effect of chamfered inlet edge of rotor inlet part with various depth-to-diameter and inlet chamfered edge angle is conducted. Depth-to-diameter ratios range from 0 to 0.5 and inlet chamfered edge angle range from 0 to 60. As a result, there is an optimal design point of inlet chamfered edge depth. And the inlet edge angle far maximum discharge coefficient is influenced mainly by the rotating speed of discharge holes.

  • PDF

A New Driving Waveform to Improve Dark Room Contrast Ratio in AC Plasma Display Panel

  • Lee, Sung-Hyun;Kim, Dong-Hyun;Ryu, Jae-Hwa;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.203-206
    • /
    • 2002
  • In this study, a new driving method is suggested to improve the dark room contrast ratio. The principles of the method are that the reset facing discharges occur between scan and address electrodes instead of surface discharge and that the discharge occurs only for the cells that experienced sustain discharge in preceding sub-field after the first sub-field. The dark room contrast ratio is improved more than 7 times compared with the conventional method.

  • PDF