• Title/Summary/Keyword: Discharge Pressure

Search Result 1,472, Processing Time 0.029 seconds

Clinical Considerations of the Surgical Closure of the PDA in the Premature Infants (미숙아 동맥관 개존증의 외과적 교정에 관한 임상적 고찰)

  • 김상익;박철현;현성열;김정철;권진형;박국양
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.702-708
    • /
    • 1999
  • Background: Surgical closure of the PDA in premature infants with complications or contraindications to indomethacin use, or recurrence of symptomatic PDA is a safe and effective procedure with low operative risk and minimal complications. Material and Method: From April 1996 to August 1998, 11 premature infants with body weight under 1.5 kg at operation underwent operation for a symptomatic PDA (male:5, female: 6). Associated dise ases were congenital heart disease(7), hyaline membrane disease(6), intraventricular hemor rhage(4), pneumonia(4), pneumothorax(3), hyperbilirubinemia(2), necrotizing enterocolitis(2), renal failure(1), epilepsy(1), and hydrocephalus(1). Surgical techniques are hemoclipping(8) and ligation(3). The size of PDA was 3~6 mm (5.0$\pm$1.2). Result: Systolic and diastolic blood pressure rised and heart rates decreased after PDA closure. ABGA improved postoperatively. There were no surgical complications. Six infants with improved ABGA data were weaned from mechanical ventilatory support. The follow-up durations after discharge were 3 month to 12 month. Five deaths were not related to operation. The causes of death were hyaline membrane disease(2), bronchopulmonary dysplasia with pneumonia(1), sepsis(1), and con gestive heart failure with respiratory distress syndrome(1). Conclusion: Early operative closure is the treatment of choice in most premature infants with a hemodynamically significant shunt(PDA), recurrence of symptomatic PDA, complications of Indomethacin, or contraindi cations to Indomethacin.

  • PDF

Analysis of Seawater Intake System using the RNG k-𝜖 Algorithm (RNG k-𝜖 알고리즘을 이용한 해수취수시스템 분석)

  • Kim, Ji-Ho;Kim, Tae-Won;Lee, Seung-Oh;Park, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6447-6454
    • /
    • 2013
  • Seawater intake systems have significant problems due to seawater pollution, suspended solids, unstable intake and maintenance etc. An underground type seawater intake system was newly developed to overcome the existing weaknesses and was facilitated in Gyukpo port. In this study, to check the performance of the new system, the samples for water quality and the 3-D numerical modeling test were conducted. The five times test included the COD, total nitrogen, total phosphorus, pH, and suspended solid for the intake system. The analyses show that the COD, total nitrogen, total phosphorus, PH showedminor changes before and after. On the other hand, the change in suspended solids was significant and water was purified below 5 mg/l, first level fisheries water, after. The numerical model adopted the RNG $k-{\epsilon}$ algorithm and the CFX model based on the finite volume method. The porosity algorithm was used to reproduce filtered-sand, outer diameter, and thickness. The numerical results showed that the double pipe is advantageous in that it provides a uniform pressure between the inner and outer pipe for the flow to be stable. In addition, the use of multiple intake pipes did not interfere with the discharge reduction of 0.98 at the both intake pipes compared with the central intake pipe.

A Study on the Lived Experiences of Homecare Nurses (가정간호사의 실무체험 연구)

  • 서문자;김소선;신경림;강현숙;김금순;박호란;김혜숙
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.1
    • /
    • pp.84-97
    • /
    • 2000
  • The Necessity and Purpose of the Study Recently the number of patients with chronic diseases and the aged patients is increasing steadily. Furthermore, due to the expansion of health insurance system, the number of patients hospitalized in the general hospital is increasing at a surprising speed. However, hospitals urge the early discharge of the patients for the efficiencies of hospital administration, and therefore, the number of patients who must be taken care of in their home is also increasing. Homecare nursing is one of the health care service for the patients at home who require continual attention and care, and now increasing attentions are given to it as one of the professional nursing fields. However, it was almost impossible to find a study on the actual experiences of the homecare nurses written by their own language in Korea, that it also posed a great difficulty in understanding their diverse experience. Considering these situation, this study will help understanding of them, and provide the fundamental data on their experiences for making policies to develop homecare nursing. Methods of Research Phenomenological research method was employed to analyze the lived experiences of homecare nurses fundamentally. Data collection Data were collected from August 1998 to December 1998 from ten homecare nurses who worked for patients under the homecare nursing setting as model cases designated by Seoul Nurses Association and who agreed to the purpose of this study after listening to and understanding the explanation completely. The in-depth interview was carried at the time which was convenient both for the researcher and participants for one or two hours, and recovered with the approval participants. The first interview covered diverse and broad areas like the situation of homecare nursing, and their feelings and thoughts over it, and in the second and third interviews, more specific questions are asked. Data Analysis For the phenomenological analysis, contents analysis was employed. The data collected from the participants were analyzed into the following procedures according to Van Manen 's phenomenological analysis. 1) Reserve the preconception of the researcher by restricting it inside parenthesis. 2) Make a thorough observation of the lived experiences by insight process. 3) Analyze the contents (Find out the repetitive factors) 4) Interpret the essence found. 5) State the meaning of the interpretation. Results and discussion 1. Fear and expectation for the first visit. (unfamiliarity, awkwardness, anxiety, shivering) 2. Mingle with the family (feeling friendly with the family, becoming like a family member) 3. Being proud of her own know-how (learning the know-how, organizing alternatives, building up confidence) 4. Pity for the poor. (criticizing the current government, feeling ashamed, feeling anger) 5. Difficulty of constructing cooperative system with physicians (strenuousness, frustration) 6. Helplessness due to the lack of support system (difficulty to get supplies, annoyance, embarrassment by institutional restraints) 7. Anxiousness for heavy traffic and parking (annoyance, hastiness) 8. Ethical conflicts (pity for the patients and family, skepticism about lengthening life maintenance) 9. Burden for the possible accident (pressure, anxiety, conflict, physical exhaustion) 10. Establishment of identity as a professional (fulfillment, worth, joy) 11. Being distressed at other's ignorance

  • PDF

Study on the Improvement of Distribution Pattern in the Triple Nozzle System (동력분무기용(動力噴霧機用) 삼분두(三噴頭)의 살포도(撒布度) 개선(改善)에 관(關)한 연구(硏究))

  • Hong, Soung Wha;Lee, Sang Woo
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.284-294
    • /
    • 1984
  • Effects of orifice diameter, operating angle and swirl chamber distance were examined to study a reasonable distribution pattern on the maximum available travel distance in the triple nozzle system. The results of the study were as follows; 1. Discharge rate was increased with increase of orifice diameter, and a quadratic line for the 1st nozzle and linear lines for the 2nd or the 3rd nozzle. 2. The operating angle of $15^{\circ}$ had showed the maximum available travel distance, and 17m in orifice diameter of 3.0mm and operating pressure of $24.5{\times}10^5pa$ ($25Kg/cm^2$). 3. Nozzle setting methods (reference Table 6.) for improvement of uniformity of deposit distribution were varied depending on the size of orifice diameter of the 1st nozzle, nevertheless coefficients of uniformity were improved about 6 percents. 4. Adjustment of the swirl chamber distance of the 2nd nozzle could improve the minimum area of about 6m from the triple nozzle.

  • PDF

The Wearing Effect of Sport Underwear -Focusing on the Loss of Weight and Amount of Sweat according to the Materials- (운동용 속옷의 착용효과 -소재별 발한량과 체중감량을 중심으로-)

  • Na, Mi-Hyang;Kim, Mi-Sun;Jung, Bock-Hee
    • Korean Journal of Human Ecology
    • /
    • v.11 no.3
    • /
    • pp.273-285
    • /
    • 2002
  • Three materials for sport underwear were manufactured by order for study, and among them, suitable material in order to perform an experiment on the effect of wearing was adopted. The results are as follows: The result of wearing an experimental clothes for sports manufactured as a foundation-type underwear for sports showed that if the same compositional materials were applied, laminating material had higher rate than that of others in the amount of sweat. Concerning relative humidity in clothes and the amount of sweat absorbed in clothes among the two kinds of materials which were produced by laminate, material 2(nylon+modal) was statistically exerts higher influence on the amount of sweat. The humidity in clothes keeps the optimal condition of 59.8%, and breast part showed the highest relative humidity. The material 2(nylon+modal) showed the highest comfortableness, the sense of warmth, humidity and voluminousness, and the sense of pressure. Follow-up survey revealed that in case of material 2, higher amount of sweat than that of the group objects in its early phase, and the amount of sweat varies from individuals. The temperature in clothes of folded parts of experimental clothes and maximum surface temperature was equivalent to that of average skin. With the lapse of time, the weight decreased of 11.03% in maximum, and 3.12% in minimum. The amount of change in the girth was greater in part of body frame than that of limbs, and especially, navel and waist part showed high decrease, and upper breast, breast and the largest part of abdomen showed relatively low decrease. The above experiment revealed that materials for suitable to the underwear for sports for loss of weight by an exercise should be made of doubled-nylon and modal, along with the laminate processing, which heightens the amount of sweat. Thus, wearing an experimental wear gave satisfaction in the view of the beauty of appearance as it did not discharge flowing secretion to the outside at the time of exercise.

  • PDF

Analysis of Air Discharge and Disused Air Filters in Radioisotope Production Facility

  • Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.156-161
    • /
    • 2016
  • When air discharged from a radioisotope production facility is contaminated with radiation, the public may be exposed to radiation. The objective of this study is to manage such radiation exposure. We measured the airborne radioactivity concentration at a 30 MeV cyclotron radioisotope production facility to assess whether the exhaust gas was contaminated. Additionally, we investigted the radioactive contamination of the air filter for efficient air purification and radiation safety control. To measure the airborne radiation concentration, specimens were collected weekly for 4 h after the beginning of the radioisotope production. Regarding the air purifier, five specimens were collected at different positions of each filter-pre-filter, high-efficiency particulate air filter, and charcoal filter-installed in the cyclotron production room. The concentrations of F-18, I-123, I-131, and Tl-201 generated in the radioiodine production room were $13.5Bq/m^3$, $27.0Bq/m^3$, $0.10Bq/m^3$, and $11.5Bq/m^3$, respectively; the concentrations of F-18, I-123, and I-131 produced in the radioisotope production room were $0.05Bq/m^3$, $16.1Bq/m^3$, and $0.45Bq/m^3$, correspondingly; and those of F-18, I-123, I-131, and Tl-201 generated in the accelerator room were $2.07Bq/m^3$, $53.0Bq/m^3$, $0.37Bq/m^3$, and $0.15Bq/m^3$, respectively. The maximum radiation concentration of I-123 generated in the radioiodine production room was 1,820 Bq/g, which can be disposed after 2 days. The maximum radiation concentration of Tl-202 generated in the radioisotope production room was 205 Bq/g, and this isotope must be stored for 53 days. The I-123 generated in the radioiodine production room had a maximum concentration of 1,530 Bq/g and must be stored for 2 days. The maximum radiation concentration of Na-22 generated in the radioisotope production room was 0.18 Bq/g and this isotope must be disposed after 827 days. To manage the exhaust, the efficiency of air purification must be enhanced by selecting an air purifier with a long life and determining the appropriate replacement time by examining the differential pressure through systematic measurements of the airborne radiation contamination level.

Investigation on the Performance of Special Purpose Automotive Air-Conditioning System Using Dual Refrigeration Cycle (듀얼 냉동사이클을 이용하는 특수목적 자동차용 에어컨 시스템의 냉방성능에 관한 연구)

  • Seo, Jae-Hyeong;Bang, You-Ma;Lee, Moo-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.213-220
    • /
    • 2016
  • The objective of this study is to investigate the cooling performance of an air-conditioning system for a special purpose vehicle under tropical and severe weather conditions. In order to evaluate and compare the cooling performances, the dual refrigeration cycle using R-134a was tested on a special purpose vehicle with various refrigerant charge amounts and indoor temperatures. The cycle was tested considering indoor cooling speed and compression ratio (discharge pressure), and was optimized at the refrigerant charge amount of 1.5 kg and outdoor temperature of $40.0^{\circ}C$. The time to reach indoor temperature of $15.0^{\circ}C$ increased by 86.5% and 38.1%, at the indoor temperatures from $25.0^{\circ}C$ to $32.5^{\circ}C$ and from $32.5^{\circ}C$ to $40.0^{\circ}C$, respectively. In addition, with the increase in indoor temperature from $25.0^{\circ}C$ to $40.0^{\circ}C$, the cooling capacity increased by 7.3%, from 19.1 kW to 20.5 kW, but decreased by 7.0% from 4.67 to 5.1.

Effectiveness of Simple Trauma Team Activation Criteria on Prognosis of Severe Trauma Patients (단순 외상팀 활성화 조건이 중증 외상 환자의 치료 결과에 미치는 영향)

  • Lee, Dong Keon;Lee, Kang Hyun;Cha, Kyoung Chul;Park, Kyoung Hye;Choi, Han Joo;Kim, Hyun;Hwang, Sung Oh
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2009
  • Purpose: The goal of this study was to compare the outcome of the after trauma team (AfterTT) group to the before trauma team (BeforeTT) group. Methods: All trauma patients who visited to emergency room (ER) between July 1, 2006 and February 29,2008 based on trauma registry, with systolic blood pressure (SBP) < 90 mmHg or GCS < 9 were included in this study. We compared the amount of packed RBC transfusion, the ER stay time, the ER visit to CT evaluation time, the ER visit to operation time, the length of ICU stay, the length of hospital admission and the survival discharge rate between the AfterTT group and the BeforeTT group. Patients with brain injuries had little chance of survival. Burn patients, who visited the ER 24 hours after injury and patients who were dead on arrival (DOA) were excluded from this study. Results: Total of 93 patients were included in this study: 42 in the AfterTT group and 51 in the BeforeTT group. The AfterTT group and the Before TT group showed no differences in Revised Trauma Score (RTS) and mean age. The amount of packed RBC transfusion was lower in the AfterTT group, but no statistically significant difference was noted (AfterTT 11${\pm}$11units, BeforeTT 16${\pm}$15units, p=0.136). The ER visit to operation time was shorter in the AfterTT group, but there were no statistically significant difference between the groups (AfterTT 251${\pm}$223 minutes, BeforeTT 486${\pm}$460 minutes, p=0.082). The length of ICU stay was shorter in the AfterTT group, but the difference was not statistically significant (AfterTT 11${\pm}$12 days, Before TT 15${\pm}$30 days, p=0.438). The length of Hospital admission was shorter in the AfterTT group (AfterTT 43${\pm}$37 days, BeforeTT 68${\pm}$70 days, p=0.032), but this difference was not statistically significant. Conclusion: Simple Trauma team activation criteria decreased the amount of packed RBC transfusion and the hospital admission duration. Hemodynamic instability (SBP < 90 mmHg) and decreased mental state (GCS<9) are good indices for activating the trauma team.

수처리 목적의 대기압플라즈마를 이용한 유사 폴리도파민 필름 증착

  • Mun, Mu-Gyeom;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.124-124
    • /
    • 2018
  • Polydopamine은 수중 접착력, 친환경 접착제, nanoparticle absorption 등 다양한 특성으로 많이 연구되고 있는 소재이다. 본 연구에서는 dopamine을 이용하여 수중 금속을 흡착시키는 thin film을 제작하였다. 종래의 Polydopamine coating 방법으로 wet coating 이 사용되고 있다. 하지만 wet 방식의 경우 시간이 오래 걸릴 뿐만 아니라 in-line, roll to roll 방식을 적용하는 것이 어렵기 때문에 생산적이지 않다. 이에 본 연구에서는 Atmospheric Pressure Plasma(APP)를 이용 하여 Polydopamine-like film을 coating 하였다. APP의 경우 vacuum system, solution tank가 필요 없고 in-line, roll to roll 방식을 적용 할 수 있기 때문에 더 경제적이고 생산적인 공정이다. 또한 기존의 Plasma polymerization 방법은 Plasma energy가 높기 때문에 source의 분자구조가 바뀌거나 atom 단위로 분해된다. source의 분자구조가 바뀌는 "Atomic polymerization", Neiswender-Rosskamp Mechanism이 적용되면 wet 방식 coating한 film과는 다른 특성을 갖게 된다. 하지만 APP polymerization은 Plasma energy가 vacuum plasma 보다 매우 낮기 때문에 stile polymerization mechanism을 구현 하는데 적합 하다. stile polymerization mechanism은 Plasma 내부에서 polymer source를 분해 성장 시켜서 Polymer film 얻는 것이 아닌 source의 분자구조가 깨지지 않으면서 polymer growing 시키는 방법이다. dopamine source의 분자구조를 최대한 유지하려고 하는 이유는 metal absorption과 같은 특성이 dopamine chemical structure에 영향을 받기 때문이다. 많은 논문들에서 dopamine의 catechol group이 metal absorption, adhesion force에 영향을 주는 주요 인자라고 주장하고 있기 때문이다. 그래서 본 논문에서는 Dopamine source의 형태를 보존하면서 Polymerization 하는 방법으로 APP process를 사용 하여 낮은 전압에서 Polydopamine-like film을 제작 하였다. APP system 의 Plasma 방전부 에 Dopamine source를 유입하기 위하여 본 논문에서는 Piezo Spray 방식을 사용 하였다. Dopamine을 evaporator 하는 것이 어렵고 chemical composition이 유사한 monomer를 사용해서 Plasma Polymerization으로 Dopamine 분자 구조를 재현하는 것도 어렵다. 그래서 본 연구에서는 Dopamine을 water에 immerse 하고 Dopamine solution을 mist 상태로 만들어서 Plasma discharge area에 유입하였다. 이러한 방법으로 만들어진 film은 Polydopamine film은 아니지만 Polydopamine film과 유사한 Chemical composition, chemical structure, metal absorption을 갖는 것을 FT-IR, SEM, XPS을 이용 하여 확인 하였다. Dopamine source의 보존에 대하여 명확하게 확인하기 위하여 FT-IR을 측정 하였다. 전압에 따른 Benzene ring, hydroxyl group의 비율을 확인 하였다. 낮은 전압으로 coating 된 Polydopamine-like film 일수록 hydroxyl group peak($3400{\sim}3000cm^{-1}$)과 비교하여 Benzene ring peak($1600{\sim}1580cm^{-1}$ and $1510{\sim}500cm^{-1}$)이 흡수를 더 많이 하는 것을 확인 할 수 있다. 이것은 Benzene ring이 파괴되지 않고 보존되는 것을 보여준다. Dopamine에서 Benzene ring은 absorption main factor인 catechol에 있는 chemical structure이다. 즉 Benzene ring peak이 높을수록 Catechol이 잘 보존 되었다는 의미 이다. Catechol의 보존은 absorption main factor가 보존 된다는 의미 이다. 이러한 Polydopamine-like film으로 As, Cr, Mg, Cu 200ppm solution에 대한 filtration 능력을 확인 하였다. As, Cr, Cu, Mg 의 제거율이 각각 약25%, 35%, 45%, 65%인 것을 확인 하였다. 이 수치는 시중에 판매되는 제품들과 비교했을 때 300%~500% 향상된 수치 이다.

  • PDF

Study on the Steam Line Break Accident for Kori Unit-1 (고리 1호기에 대한 증기배관 파열사고 연구)

  • Tae Woon Kim;Jung In Choi;Un Chul Lee;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.186-195
    • /
    • 1982
  • The steam line break accident for Kori Unit 1 is analyzed by a code SYSRAN which calculates nuclear power and heat flux using the point kinetics equation and the lumped-parameter model and calculates system transient using the mass and energy balance equation with the assumption of uniform reactor coolant system pressure. The 1.4 f $t^2$ steam line break accident is analyzed at EOL (End of Life), hot shutdown condition in which case the accident would be most severe. The steam discharge rate is assumed to follow the Moody critical flow model. The results reveal the peak heat flux of 38% of nominal full power value at 60 second after the accident initiates, which is higher than the FSAR result of 26%. Trends for the transient are in good agreement with FSAR results. A sensitivity study shows that this accident is most sensitive to the moderator density coefficient and the lower plenum mixing factor. The DNBR calculation under the assumption of $F_{{\Delta}H}$=3.66, which is used in the FSAR with all the control and the shutdown assemblies inserted except one B bank assembly and of Fz=1.55 shows that minimum DNBR reaches 1.62 at 60 second, indicating that the fuel failure is not anticipated to occur. The point kinetics equation, the lumped-parameter model and the system transient model which uses the mass and energy balance equation are verified to be effective to follow the system transient phenomena of the nuclear power plants.lear power plants.

  • PDF