• Title/Summary/Keyword: Discharge Pressure

Search Result 1,472, Processing Time 0.035 seconds

Study on the Detoxification of Lacca Sinica Exsiccata Written in the Classical Writings (건칠(乾漆)의 해독방법에 대한 문헌연구)

  • Lee Jae-Ho;Kim Young-Sam;Han Gyu-Jo;Kim Myoung-Dong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1169-1180
    • /
    • 2005
  • First, I read all the materials, including Dongeuibogam(Encyclopedia Medica Koreana), classical writings on Lacca sinica exsiccata, herbal writings on lacquer poison, and herbal books on how to treat lacquer poison. And then after 1 examined all the details on qi and taste of Lacca sinica exsiccata, its efficacy, detoxification, lacquer poison, and its effects on body symptom, 1 got the following results. The order of frequency that Lacca sinica exsiccata is used in Dongeuibogam is pressure-feeling, blood circulation, and insect biting. Its way of intake is not so much through herb-boiling or powdered medicine as through hand-made pills. When medicine is used in the form of pills, the Lacca sinica exsiccata is more included among other ingredients. When old doctors treated pressure-feeling in the chest, they mixed up other herbs, with not putting more emphasis on the efficacy of lacquer 010 doctors believed that toxicity of Lacca sinica exsiccata is not having its own poison, but having biased dominance in the use of its qE and taste. The way or detoxification or Lacca sinica exsiccata is used in the order of crab-boiled water, egg, Xanthoxylum piperitum, Perilla frutescens, Astar tataricus, a weeping willow, iron-tempered water, and Allium toberosum. Special point in detoxificating lacquer poison is that they used medicines for well-ciruculating pulmonary stream, medicines for promoting to urinate or discharge by helping large colons to move, medicines for making the lacquer scar small, medicines for helping digest, and medicines for improving vessel function in the poisoned area. With the above results, the more profound study, based on the crab-boiled water and egg, is expected to go on to increase the effect on the one hand, and to make the new way of lessening or removing the toxicity of lacquer with more safe use on the other hand.

Dynamics of Attached Microbial Community on the River with Gravel Riverbed (자갈하상 하천에서 부착미생물군집의 거동)

  • Park, Jae-Young;Choi, I-Song;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.3 s.152
    • /
    • pp.235-244
    • /
    • 2005
  • This study was carried out in Osan river to quantitatively investigate behavior of attacked microbial community (AMC) for enhancing self-purification process of river. We gained the results such as follows throughout long-term monitoring at in-situ river. The biomass of AMC had higher in the riffle than the almost stagnant pool and they were more developed in the riffle with high current velocity (HCV). Although the fast flowing current affects negatively to growth of the AMC during the early phase when the community gets attached to the benthic substrate, it was observed that it affected positively to their growth during the intermediate and later phase after the community is adapted to the substrate. When turbulence due to external pressure (storm or discharge of dam and reservoir) occurs, the degree of separation depends upon the flowing strength and the type of the external pressure. Since the community is not all separated, recovery is rather fast. Therefore, this study found that the degree of reduction of the pollutant by self-purification of the stream is depended upon the riverbed shape and the AMC contributes to self-purification positively or negatively in river. Therefore, the riverbed shape must be constructed in accordance with the characteristics of water quality in stream. Furthermore, the technique of installing the water channel structure appropriate for each section must be developed to maximize self-purification ability.

Research on the Multi-electrode Plasma Discharge for the Large Area PECVD Processing

  • Lee, Yun-Seong;You, Dae-Ho;Seol, You-Bin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.478-478
    • /
    • 2012
  • Recently, there are many researches in order to increase the deposition rate (D/R) and improve film uniformity and quality in the deposition of microcrystalline silicon thin film. These two factors are the most important issues in the fabrication of the thin film solar cell, and for the purpose of that, several process conditions, including the large area electrode (more than 1.1 X 1.3 (m2)), higher pressure (1 ~ 10 (Torr)), and very high frequency regime (VHF, 40 ~ 100 (MHz)), have been needed. But, in the case of large-area capacitively coupled discharges (CCP) driven at frequencies higher than the usual RF (13.56 (MHz)) frequency, the standing wave and skin effects should be the critical problems for obtaining the good plasma uniformity, and the ion damage on the thin film layer due to the high voltage between the substrate and the bulk plasma might cause the defects which degrade the film quality. In this study, we will propose the new concept of the large-area multi-electrode (a new multi-electrode concept for the large-area plasma source), which consists of a series of electrodes and grounds arranged by turns. The experimental results with this new electrode showed the processing performances of high D/R (1 ~ 2 (nm/sec)), controllable crystallinity (~70% and controllable), and good uniformity (less than 10%) at the conditions of the relatively high frequency of 40 MHz in the large-area electrode of 280 X 540 mm2. And, we also observed the SEM images of the deposited thin film at the conditions of peeling, normal microcrystalline, and powder formation, and discussed the mechanisms of the crystal formation and voids generation in the film in order to try the enhancement of the film quality compared to the cases of normal VHF capacitive discharges. Also, we will discuss the relation between the processing parameters (including gap length between electrode and substrate, operating pressure) and the processing results (D/R and crystallinity) with the process condition map for ${\mu}c$-Si:H formation at a fixed input power and gas flow rate. Finally, we will discuss the potential of the multi-electrode of the 3.5G-class large-area plasma processing (650 X 550 (mm2) to the possibility of the expansion of the new electrode concept to 8G class large-area plasma processing and the additional issues in order to improve the process efficiency.

  • PDF

Study on the simulation of a spark ignition engine using BOOST (상용 소프트웨어를 이용한 스파크 점화 기관의 시뮬레이션에 관한 연구)

  • Jeong, Chang-Sik;Woo, Seok-Keun;Ryu, Soon-Pil;Yoon, Keon-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.733-742
    • /
    • 2016
  • In recent years, gas engines fueled with LNG or synthetic gas have been attracting considerable attention for marine use owing to their potential to facilitate better fuel economy and to reduce emissions. It has been confirmed that gas engines using the Otto cycle, which involves premixed combustion, can satisfy Tier III regulations without the EGR or SCR system. The objective of this study is to acquire simulation technologies for predicting gas engine performances in industrial fields. Using the commercial software BOOST, the simulation is conducted on a gasoline engine rather than a marine engine due to the gasoline engine's easier accessibility. This study consists of two stages. In the first stage published previously, the optimal modeling techniques for representing the behavior of the gas in the intake and exhaust systems were determined. In the current study, we formulated a method to evaluate the combustion and heat transfer processes in the cylinder and to ultimately determine the major performance parameters, given that the analytical model derived from the previous stage has been applied. Through this study, we were able to determine a combustion and heat transfer model and a valve discharge coefficient that are less reliant on empirical data: we were also able to formulate a methodology through which relevant constants are decided. We confirmed that the values of transient cylinder pressure variation, indicated mean effective pressure, and air supply can be successfully predicted using our modeling techniques.

Effects of Systemic and Focal Hypoxia on the Activities of Rostral Ventrolateral Medullary Neurons in Cats

  • Yan, Hai-Dun;Kim, Charn;Kim, Ji-Mok;Lim, Won-Il;Kim, Sang-Jeong;Kim, Jun
    • The Korean Journal of Physiology
    • /
    • v.30 no.1
    • /
    • pp.105-116
    • /
    • 1996
  • Rendering the brain ischemic would evoke the cerebral ischemic reflex which is characterized by an arterial pressor response, apnea and bradycardia. Since the rostral ventrolateral medulla (RVLM) is known to play a key role in the maintenance of normal cardiopulmonary activity, during the cerebral ischemic reflex some cardiac related cells should be excited and respiration related cells inhibited. In this context, the responses of RVLM neurons to systemie and focal hypoxia were analyzed in the present study. Twenty-five adult cats of either sex were anesthetized with ${\alpha}-chloralose$ and the single neuronal activities were identified from RVLM area. For the induction of focal hypoxia in the recording site, sodium cyanide was applied iontophoretically and for systemic hypoxia the animal was ventilated with nitrogen gas for a twenty-second period. Cellular activities were analyzed in terms of their discharge pattern and responses to the hypoxia by using post-stimulus time and single-pass time histograms. Of eighteen cardiac related cells recorded from the RVLM area, twelve cells were excited by iontophoresed sodium cyanide and of twenty-five respiration related cells, fourteen cells were excited by iontophoresed sodium cyanide. Remaining cells were either inhibited or unaffected. Eight of fifteen cells tested with iontophoresed sodium lactate were excited and remaining seven cells were inhibited. Systemic hypoxia induced by nitrogen gas inhalation elevated the arterial blood pressure, but excited, inhibited or unaffected the single neuronal activities. Some cells showed initial excitation followed by inhibition during the systemic hypoxia. Bilateral vagotomy resulted in a decrease of arterial pressor response to the systemic hypoxia, and a slight decrease in the rhythmicity related to cardiac and/or respiratory rhythms. The single neuronal responses to either systemic or focal hypoxia were not affected qualitatively by vagotomy. From the above results, it was concluded that the majority of the cardiac- and respiration- related neurons in the rostral ventrolateral medulla be excited by hypoxia, not through the mediation of peripheral chemoreceptors, and along with the remaining inhibited cells, all these cells be involved in the mediation of cerebral ischemic reflex.

  • PDF

Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

  • Mukin, Roman;Clifford, Ivor;Zerkak, Omar;Ferroukhi, Hakim
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.356-367
    • /
    • 2018
  • A series of tests dedicated to station blackout (SBO) accident scenarios have been recently performed at the $Prim{\ddot{a}}rkreislauf-Versuchsanlage$ (primary coolant loop test facility; PKL) facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal-hydraulic code TRACE (v5.0 Patch4) of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG) feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC) injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for secondary side depressurization affects the heat transfer from primary side; how the discharge capacity of the pressurizer relief valve affects the dynamics of the transient; how ACC initial pressure and nitrogen release affect the grace time between ACC injection and subsequent core heat up; and how well the alternative feeding modes of the secondary and/or primary side with mobile injection pumps affect core quenching and ensure stable long-term core cooling under controlled boiling conditions.

Safety evaluation of atmospheric pressure plasma jets in in vitro and in vivo experiments

  • Lee, Ji-Yoon;Park, Shin-Young;Kim, Kyoung-Hwa;Yoon, Sung-Young;Kim, Gon-Ho;Lee, Yong-Moo;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.3
    • /
    • pp.213-223
    • /
    • 2021
  • Purpose: The atmospheric pressure plasma jet (APPJ) has been introduced as an effective disinfection method for titanium surfaces due to their massive radical generation at low temperatures. Helium (He) has been widely applied as a discharge gas in APPJ due to its bactericidal effects and was proven to be effective in our previous study. This study aimed to evaluate the safety and effects of He-APPJ application at both the cell and tissue levels. Methods: Cellular-level responses were examined using human gingival fibroblasts and osteoblasts (MC3T3-E1 cells). He-APPJ was administered to the cells in the experimental group, while the control group received only He-gas treatment. Immediate cell responses and recovery after He-APPJ treatment were examined in both cell groups. The effect of He-APPJ on osteogenic differentiation was evaluated via an alkaline phosphatase activity assay. In vivo, He-APPJ treatment was administered to rat calvarial bone and the adjacent periosteum, and samples were harvested for histological examination. Results: He-APPJ treatment for 5 minutes induced irreversible effects in both human gingival fibroblasts and osteoblasts in vitro. Immediate cell detachment of human gingival fibroblasts and osteoblasts was shown regardless of treatment time. However, the detached areas in the groups treated for 1 or 3 minutes were completely repopulated within 7 days. Alkaline phosphatase activity was not influenced by 1 or 3 minutes of plasma treatment, but was significantly lower in the 5 minute-treated group (P=0.002). In vivo, He-APPJ treatment was administered to rat calvaria and periosteum for 1 or 3 minutes. No pathogenic changes occurred at 7 days after He-APPJ treatment in the He-APPJ-treated group compared to the control group (He gas only). Conclusions: Direct He-APPJ treatment for up to 3 minutes showed no harmful effects at either the cell or tissue level.

A study of the space sterilization device using atmospheric-pressure DBDs plasma (대기압 유전체장벽방전을 적용한 플라즈마오존 공간살균장치에 관한 연구)

  • Oh, Hee-Su;Lee, Kang-yeon;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.281-289
    • /
    • 2022
  • Plasma ozone is utilized in a variety of applications in the field of sterilization due to its high sterilization performance. Dielectric materials used in DBD(dielectric barrier discharges) are mainly polymer, quartz and ceramics. These dielectric layers have the advantage of limiting the amount of supplied electron charge and allowing plasma to occur evenly on the surface of dielectric. Actually, the target or environment for sterilization is often a complex structure, so research and academic study are needed by utilizing the concept of space sterilization. In this study, the device is applied to generate DBD plasma at atmospheric pressure for disinfection due to the effectiveness in producing radicals and ozone. The generator of plasma ozone is a basic structure of dielectric barrier discharge by placing ceramic tube dielectrics and stainless steel electrical conductors at regular intervals. Various applications can be developed based on the proposed design method. Plasma ozone generation for space sterilization device is recognized as an excellent sterilization device. Through the design and verification of the device, we intend to establish an optimal design of the spatial sterilization device and provide the basis data for sterilization applications.

Effect of Pesticide Residues on Perilla Leaf by Nozzle Types of Knapsack Sprayers (배부식 분무기 노즐이 들깻잎의 농약잔류에 미치는 영향)

  • Son, Kyeong-Ae;Kang, Tae Kyeong;Park, Byeong Jun;Jin, Yong-Duk;Gil, Geun-Hwan;Kim, Chan Sub;Kim, Jin Bae;Im, Geon-Jae;Lee, Key-Woon
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.282-287
    • /
    • 2012
  • This study was carried out to clarify the effects of the application of pesticide by different spray nozzle types on pesticide residues. The average droplet size and discharge rate were investigated when the manual compressed sprayer with two head disk type nozzle and the knapsack engine powered sprayer with two head fan shape nozzles were used. The fan type nozzles were classified into three types by the number of orifice in the nozzle. Three type nozzles tested were fan with one orifice, fan with two orifices and fan with three orifices. Fan (trade name : D-3) with 2.4 L/min. of the discharge rate and $76{\mu}m$ of the average droplet size while maintaining constant pressure $1.1{\pm}0.2$ MPa, and fan D-35 with 2.6 L/min. and $90{\mu}m$ while maintaining constant pressure $1.0{\pm}0.2$ MPa were appropriate. The orifice size of D-3 was 0.65 mm length ${\times}$ 0.45 mm width and the orifice size of D-35 was 0.62 mm length ${\times}$ 0.46 mm width. The residue levels of imidacloprid on perilla leaves among four applications by four different nozzles show significantly difference with 5% significance level. The residue levels $3.76{\sim}3.92mg\;kg^{-1}$ by fan or disk type is smaller than $4.52{\sim}4.92mg\;kg^{-1}$ by fan II or fan III. The residue levels of imidacloprid on perilla leaf were different depend on the spray nozzles type.

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF