• Title/Summary/Keyword: Discharge Pressure

Search Result 1,480, Processing Time 0.029 seconds

Applied Sound Frequency Monitoring in the Transformer Oil Using Fiber Optic Sagnac Interferometer (사냑형 간섭계 광섬유 센서를 이용한 변압기유 내에서의 외부 음향 주파수 모니터링)

  • Lee, Jongkil;Lee, Seunghong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.288-294
    • /
    • 2015
  • The fiber optic Sagnac interferometer is well established as a sensor for detection of physical perturbations such as acoustic and vibration. In this paper acoustic signals generated in the cylindrical cavity submerged in transformer oil were measured by the fiber optic sensor array in one Sagnac loop. Two different external sound frequencies, $f_1$ and $f_2$, were applied to the sensor array simultaneously by using piezoelectric with frequency range from 5 kHz to 90 kHz. Based on the experimental results, fiber optic sensor detected harmonic series of applied sound frequency such as $f_1$, $f_2$, $2f_1$, $2f_2$, ${\mid}f_1-f_2{\mid}$, ${\mid}f_1+f_2{\mid}$. Suggested fiber optic sensor array can be applied to monitor physical quantities such as internal sound pressure and vibration due to partial discharge in the real electric transformer system.

Permeation Characteristics of the Microfiltration Tubular Module using the Discharged Rod (배출봉을 이용한 정밀여과용 관형 모듈의 투과특성)

  • Chung, Kun-Yong;Choi, Jeong-Gyu
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.285-290
    • /
    • 2009
  • The permeation experiments were carried out for the nominal pore size $0.1\;{\mu}m$ and 5 mm inner diameter microfiltration tubular membrane equipped with self-designed discharging rod in order to determine the effect of fouling reduction. Dioctyl tinoxide (DOTO) latex particle was used to prepare up to 0.5 wt% concentration of feed solution, and the experiments were operated within 1.6 bar. The permeation flux effect on the discharged rod was measured as a result of flux comparison between the cases of equipped and non-equipped discharge rod modules for every experiment. The permeation flux for the case using the discharged rod was enhanced to 20% at 1.6 bar operating pressure. The improvement on permeation flux for using the discharged rod was greater as the concentration of feed increased, and reached up to 43% under 0.5 wt% concentration of feed solution.

Electrode properties upon the substitution of Mo for Mn in Zr-basd AB2-type Hydrogen Storage Alloys (Zr1-xTixV0.4Ni1.2Mn0.4-yMoy계 합금전극의 Mo 함량에 따른 물성 및 전극특성)

  • Seo, Chan-Yeol;Park, Choong-Nyeon
    • Journal of Hydrogen and New Energy
    • /
    • v.11 no.4
    • /
    • pp.189-202
    • /
    • 2000
  • $AB_2$ type Zr-based Laves phases alloys have been studied for potential application as a negative electrode in a Ni-MH battery. The $AB_2$-type electrodes have a much higher energy density than $AB_5$-type electrodes per weight, however they have some disadvantages such as poor activation behavior and cycle life etc. Nonetheless, the $AB_2$-type electrodes have been studied very extensively due to their high energy density. In this study, in order to develop the cycle life, the Mn of $AB_2$ alloy composition was substituted partially by Mo. The alloys were melted by arc furnace and remelted 4-5 times for homogeneity. The alloy powder was used below 200-325 mesh for experiments. The structures and phases of the alloys were analyzed by XRD, SEM and EDS, and measured the curve of a pressure-composition isotherms. The electrodes were prepared by cold pressing of the copper-coated(25 wt%) alloy powders, and tested by a half cell. The results are summarized as follows. The cycle life was improved with the increase of Mo amount in $Zr_{1-x}Ti_xV_{0.4}Ni_{1.2}Mn_{0.4}Mo_y$(x=0.3, 0.4) and the activation was faster, whereas the discharge capacity decreased.

  • PDF

Study on CO2 Decomposition using Ar/CO2 Inductively Coupled Plasma (아르곤/이산화탄소 혼합가스의 유도 결합 플라즈마를 이용한 이산화탄소 분해 연구)

  • Kim, Kyung-Hyun;Kim, Kwan-Yong;Lee, Hyo-Chang;Chung, Chin-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.135-140
    • /
    • 2015
  • Decomposition of carbon dioxide is studied using $Ar/CO_2$ mixture inductively coupled plasmas (ICP). Argon gas was added to generate plasma which has high electron density. To measure decomposition rate of $CO_2$, optical emission actinometry is used. Changing input power, pressure and mixture ratio, the plasma parameters and the spectrum intensity were measured using single Langmuir probe and spectroscope. The source characteristic of Carbon dioxide ICP observed from the obtained plasma parameters. The decomposition rate is evolved depending on the reaction and discharge mode. This result is analyzed with both the measurement of the plasma parameters and the dissociation mechanism of $CO_2$.

Characteristic as a Resonance Frequency of $SF_6$ Gas (SF6 가스중의 공진주파수에 따른 신호특성)

  • Lee, Y.H.;Lee, H.D.;Park, J.N.;Shin, Y.S.;Park, J.S.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1867-1869
    • /
    • 2003
  • In this paper, chamber(Circuit breaker compartment of C-GIS) made of stainless steel with 4 mm width is used. Artificial defect was made on enclosure or HV conductor of chamber and $SF_6$ gas was injected into it according to pressure. In this experiment, Acoustic emission sensors of different types was used to compare sensitivity to detect acoustic signal occurred by Partial discharge(PD) of according to types and resonance frequency in $SF_6$ gas atmosphere. Sensors used in tests was R6I, R15I and 2/4/6 Pre-Amplifier connected with R6IU without pre. amp. In case of R6IU, gain was adjusted with 40 dB like other sensors and operated by differential mode. Post amplifier(post. amp) and band pass filter(BPF) were developed Gain of post. amp. is 60 dB and BPF has band width of $50{\sim}300$ kHz. Also, envelope circuit developed reduces frequency of AE sensor. As a result, in $SF_6$ atmosphere, R6IU and R6I had resonance frequency of 60 Hz was better than R15I. Also, R6IU was better than R6I because of type property of pre.amp. had differential mode.

  • PDF

Water Hammer in the Pump Pipeline System with an Air Chamber (에어챔버가 설치된 가압펌프 계통에서의 수격현상)

  • Kim, Sang-Gyun;Lee, Kye-Bock
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.187-193
    • /
    • 2007
  • Water hammer following the tripping of pumps can lead to overpressures and negative pressures. Reduction in overpressure and negative pressure may be necessary to avoid failure, to improve the efficiency of operation and to avoid fatigue of system components. The field tests on the water hammer have been conducted on the pump rising pipeline system with an air chamber. The hydraulic transient is modeled using the method of characteristics. Minimizing the least squares problem representing the difference between the measured and predicted transient response in the system performs the calibration of the simulation program. Among the input variables used in the water hammer analysis, the effects of the polytropic exponent, the discharge coefficient and the wave speed on the result of the numerical analysis were examined. The computer program developed in this study will be useful in designing the optimum parameters of an air chamber for the real pump pipeline system. The correct selection of air chamber size and the effects of related parameters to minimize water hammer have been investigated by both field measurements and numerical modeling.

Optical Characteristic Analysis of Electrodeless Lamp due to the Density Difference of Mercury (수은의 밀도차에 의한 무전극 램프의 광특성 분석)

  • Lee, Kye-Seung;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.477-486
    • /
    • 2017
  • For the analysis of the optical characteristics of electrodeless lamps, all the lamp surface temperatures have been treated the same. However, the interpretation of optical properties in this way has not been sufficient in terms of accuracy. In this paper, to overcome this problem, we divided the inside of the bulb into two parts, hot spot and cold spot, and analyzed the density difference of mercury by different temperatures. Here, it is assumed that the distribution of temperature and density is linear. The effect of optical characteristics through redistribution of hot spot and cold spot density was analyzed. It was also confirmed that the ratio of the density of the redistributed discharge gas has a great influence on the saturation of the optical characteristics. Therefore, it is proved that the design method through the domestic setting is very useful in the actual design, and the method for shortening the time for stabilizing the optical characteristics is obtained.

Effect of favorite music therapy on anxiety and vital sign in patients undergoing gynecologic surgery using the general anesthesia (선호 음악요법이 전신마취 산부인과 수술 환자의 불안과 활력 징후에 미치는 효과)

  • Yang, Jung-Lim;Noh, Min-Young;Yang, Kyung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1189-1199
    • /
    • 2015
  • This study examined the effects of favorite music therapy on the anxiety and vital signs at each point in gynecologic surgery using the general anesthesia. The research design was a non-equivalent control group non-synchronized design. The data were collected from May 1 to July 30, 2013 and the participants were 44 patients (experimental group, 21, control group, 23) received music therapy while waiting for anesthetic induction and PACU (Post Anesthesia Care Unit). Repeated measures ANOVA was performed to analyze the data by SPSS 18.0. Music therapy reduced the anxiety level at inducing the anesthetic time, and awakening time (p=.003; p=.011). The systolic blood pressure maintained stability at discharge from the PACU (p=.023), and pulse rate was stable at the awakening time (p=.016). This findings support the use of music as a nursing intervention to reduce anxiety and maintain the vital signs for gynecologic surgery patients under general anesthesia.

Performance Simulation of Flow Control Oil Pump for Auto Transmission According to Rotating Speed (자동변속기용 유량제어 오일펌프의 회전속도 변화에 따른 성능 해석)

  • Moon, Han-Byul;Cho, Hong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3044-3050
    • /
    • 2015
  • The purpose of this study is to analyze the performance of the flow control oil pump for automatic transmission. The numerical model for analysis the performance of the flow control oil pump was develop and the characteristics of the internal flow, discharge flow rate, displacement of outer ring, driving torque, generation of cavitation was investigated according to rotating speed. As a result, the cavitation generation increased as the rotating speed increased. The volumetric efficiency was 90% for 2200 rpm and it decreased rapidly, then it decreased about 81% for 5000 rpm. Besides, the cavitation generation was 20%~30% for inlet of suction part, but it reduced below 13% owing to the compression. However, it shows higher cavitation generation for high rotating speed like 5000 rpm.

High Performance ESD/Surge Protection Capability of Bidirectional Flip Chip Transient Voltage Suppression Diodes

  • Pharkphoumy, Sakhone;Khurelbaatar, Zagarzusem;Janardhanam, Valliedu;Choi, Chel-Jong;Shim, Kyu-Hwan;Daoheung, Daoheung;Bouangeun, Bouangeun;Choi, Sang-Sik;Cho, Deok-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.4
    • /
    • pp.196-200
    • /
    • 2016
  • We have developed new electrostatic discharge (ESD) protection devices with, bidirectional flip chip transient voltage suppression. The devices differ in their epitaxial (epi) layers, which were grown by reduced pressure chemical vapor deposition (RPCVD). Their ESD properties were characterized using current-voltage (I-V), capacitance-voltage (C-V) measurement, and ESD analysis, including IEC61000-4-2, surge, and transmission line pulse (TLP) methods. Two BD-FCTVS diodes consisting of either a thick (12 μm) or thin (6 μm), n-Si epi layer showed the same reverse voltage of 8 V, very small reverse current level, and symmetric I-V and C-V curves. The damage found near the corner of the metal pads indicates that the size and shape of the radius governs their failure modes. The BD-FCTVS device made with a thin n- epi layer showed better performance than that made with a thick one in terms of enhancement of the features of ESD robustness, reliability, and protection capability. Therefore, this works confirms that the optimization of device parameters in conjunction with the doping concentration and thickness of epi layers be used to achieve high performance ESD properties.