Dissolution Characteristics of Copper Oxide in Gas-liquid Hybrid Atmospheric Pressure Plasma Reactor Using Organic Acid Solution

  • Kwon, Heoung Su;Lee, Won Gyu
    • 공업화학
    • /
    • 제33권2호
    • /
    • pp.229-233
    • /
    • 2022
  • In this study, a gas-liquid hybrid atmospheric pressure plasma reactor of the dielectric barrier discharge method was fabricated and characterized. The solubility of copper oxide in the organic acid solution was increased when argon having a larger atomic weight than helium was used during plasma discharge. There was no significant effect of mixing organic acid solutions under plasma discharge treatment on the variation of copper oxide's solubility. As the applied voltage for plasma discharge and the concentration of the organic acid solution increased, the dissolution and removal power of the copper oxide layer increased. Solubility of copper oxide was more affected by the concentration in organic acid solution rather than the variation of plasma applied voltage. The usefulness of hybrid plasma reactor for the surface cleaning process was confirmed.

왕복동식 수소압축기의 토출구 유동에 관한 CFD해석 (CFD Analysis on Discharge Passage Flow of Hydrogen Reciprocating Compressor)

  • 이경환;;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.561-566
    • /
    • 2008
  • The reciprocating compressor is widely used in the industry field, because it has simple principle and high efficiency. In this work, in order to improve design of discharge passage line in hydrogen compression system Numerical analysis was conducted. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including velocity, pressure and turbulence kinetic energy distribution of hydrogen gas going out from the cylinder to discharge-path line are presented in this paper. Discharge-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows velocity, pressure and turbulent kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement might be done.

  • PDF

대체냉매 공기조화기용 로터리 압축기의 성능향상을 위한 최적 토출계에 관한 실험적 연구 (An Experimental Study on the High Performance Optimal Discharge System of a Rotary Compressor for an Air Conditioner using alternative Refrigerant R410a)

  • 윤영;정진택;민만기
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.96-105
    • /
    • 2001
  • R410a which is one of HFC refrigerants is being considered to be a promising replacement for R22 widely used in domestic air conditioners. The rolling piston type rotary compressors for R410a have lower energy efficiency than those for R22 because of the high pressure difference between a suction chamber and a discharge chamber in the compression mechanism. in addition, the re-expansion gas loss of the rotary compressor for R410a which occurs a ta clearance volume in a discharge port becomes larger than that for R22 due to high density of R410a refrigerant. Therefore, Pressure-Volume analyses for various design parameters of a discharge system were carried out to improve efficiency of a R410a rotary compressor. The results such as performance dta, over-compression loss, and re-expansion loss were acquired by P-V analyses and analyzed quantitatively. As a conclusion, the optimal specifications of several design parameters of a discharge system were obtained by analyzing P-V diagrams.

  • PDF

실내실험과 현장실험을 통한 다양한 PVD의 연약지반개량효과 (Laboratory Test and Field Study of Soft Ground Improvement Effect by Using Various PVDs)

  • 신은철;쟌나라 나자로바
    • 한국지반신소재학회논문집
    • /
    • 제7권2호
    • /
    • pp.15-21
    • /
    • 2008
  • 인공연직배수재는 일반적인 샌드드래인에 비하여 비용 절감, 지반 교란의 최소화, 시공성 및, 시공 중에 발생될 수 있는 배수재의 변형을 최소화하는 유연성을 지니고 있다. 본 연구에서는 실내실험을 통하여 측압과 동수경사에 따른 여러형태 PVD의 통수능을 도출하였다. 시험결과는 압밀된 점토에 대한 과압력이 증가하였으며, 또한 PVD 공시체의 측압도 증가하였다. 이는 측압이 증가함에 따라 통수능이 감소됨을 나타내고 있으며, PVD 코어의 공극크기는 통수능과 비례관계에 있음을 보여준다. 현장조건을 고려하여 시뮬레이션을 통한 침하량에 대한 수치해석을 수행한 결과 현장계측한 침하량과 유사하게 나타났다.

  • PDF

Development of an advanced atmospheric pressure plasma source with high spatial uniformity and selectiveness for surface treatment

  • 임유봉;최원호;이승훈;한우용;이종현;이상균;하정민;김종훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.176-177
    • /
    • 2016
  • In the last few decades, attention toward atmospheric pressure plasma (APP) has been greatly increased due to the numerous advantages of those applications, such as non-necessity of high vacuum facility, easy setup and operation, and low temperature operation. The practical applications of APP can be found in a wide spectrum of fields from the functionalization of material surfaces to sterilization of medical devices. In the secondary battery industry, separator film has been typically treated by APP to enhance adhesion strength between adjacent films. In this process, the plasma is required to have high stability and uniformity for better performance of the battery. Dielectric barrier discharge (DBD) was usually adopted to limit overcurrent in the plasma, and we developed the pre-discharge technology to overcome the drawbacks of streamer discharge in the conventional DBD source which makes it possible to produce a super-stable plasma at atmospheric pressure. Simulations for the fluid flow and electric field were parametrically performed to find the optimized design for the linear jet plasma source. The developed plasma source (Plasmapp LJPS-200) exhibits spatial non-uniformity of less than 3%, and the adhesion strength between the separator and electrode films was observed to increase 17% by the plasma treatment.

  • PDF

무전극 형광램프 국내외 표준화 동향 (A Trend of the National and International Standards for Fluorescent Induction Lamps)

  • 조미령;신상욱;이세현;황명근;이도영;양승용;함중걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.145-147
    • /
    • 2007
  • Fluorescent induction lamps are assembly of a Low Pressure Mercury discharge vessel and an inductive power coupler. A vessel containing at least a Low Pressure Mercury vapor, which will be energized by means of the Inductive Coupler. The Ultra Violet radiation from the resulting discharge is converted by a layer of fluorescent material into visible light. The discharge vessel may have means of mechanical fixation to position it to the Inductive power coupler. The component to transform High Frequency electrical energy, by means of induction, in order to energize the Low Pressure Mercury in the discharge vessel. The component includes electrical connection. Fluorescent induction lamps don't have international standards yet. So we try to correspond Korea standards to international standards.

  • PDF

배수재의 직경과 형상변화가 수평진공배수에 미치는 영향 (Effects of Size and Shape of Drain on Horizontal Vacuum Drain)

  • 유남재;박병수;정길수;이병곤
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.293-301
    • /
    • 2001
  • This paper is experimental results of investigating the efficiency of horizontal vacuum drainage system. Effects of size and shape of drain on horizontal vacuum drainage were studied. Model tests in the laboratory with soft marine clay were carried out with drain pipe of having three different diameters and PBD (Plastic Board Drain) of strip shape so that consolidation settlement of soft clay due to applied vacuum pressure, amount of discharge, ground settlement and distributions of pore pressure and undrained shear strength were measured during testing. From results of model test, amount of discharge due to vacuum pressure was increased with the diameter of pipe drain whereas the drain efficiency of pipe in per unit area of drain surface was decreased with diameter of pipe. The rate of discharge per unit time was reduced very fast with diameter of pipe. Settlement of ground surface with time was increased with diameter of pipe as a result of increase of discharge to drain pipe.

  • PDF

연료 과농 환경에서 분사기 유량 통과 특성 연구 (Study of Flow Discharging Characteristics of Injectors at Fuel Rich Conditions)

  • 서성현;임병직;김문기;안규복;김종규;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.9-12
    • /
    • 2010
  • 본 논문은 연료 과농 연소 환경 하의 이중 와류 동축형 분사기의 유량 통과 특성 파악을 위해 수행한 실험결과를 수록하였다. 액체산소와 케로신(Jet A-1)을 사용하여 연소시험을 수행하고 유량 통과 특성을 유량계수로 표현하였다. 유량계수 산출을 위해 유량, 압력, 온도를 계측하였다. 연료 분사기의 경우, 산화제 측 분사기 형상, 연소압, 혼합비에 관계없이 일정한 유량 계수 값을 보였다. 이에 반해 산화제 분사기는 연소압과 혼합비 변화에 영향을 받는 것으로 나타났다. 화염 형성 변화가 유량계수 변화에 특히 산화제 측에 영향을 주고 있음을 밝혔다.

  • PDF

A Method to Monitor Vacuum Degree Using Capacitive Partial Discharge Coupler

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Yi, Sang-Hwa;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.959-964
    • /
    • 2012
  • Internal pressure of vacuum interrupter (VI) is one of the most important parameters in VI operation and may increase due to the outgassing from the materials inside VI or gas permeation through metal flange or ceramic vessel. The increase of the pressure above a certain level leads to the failures of switching or insulation. Therefore, an effective pressure check of VI is essential and an analysis of partial discharge (PD) characteristics is an effective monitoring method to identify the degree of the internal pressure of VI. This paper introduces a research work on monitoring the internal pressure of VI by analyzing PDs which were measured using a capacitive PD coupler. The authors have developed cost effective capacitive coupler based on the ceramic material that has an excellent insulation properties and the main component of the capacitive coupler is made by SrTiO3. Detectable internal pressure range and distinguishability of the internal pressure of VI were investigated. From the PD tests results, the internal pressure range, from $10^{-2}$ torr to 500 torr, can be monitored by PD measurements using the capacitive coupler and PD inception voltage (PDIV) follows the Paschen's law. In addition, rise time of PD pulse at 13.2kV decreases with the increase of the internal pressure of VI.

신회유동을 갖는 압력식 분무기의 분무특성에 관한 연구 (An Experimental Study on the Spray Characteristics of the Pressure Swirl Atomizer)

  • 조대진;윤석주
    • 한국분무공학회지
    • /
    • 제2권1호
    • /
    • pp.46-51
    • /
    • 1997
  • In this study, spray characteristics of the pressure swirl atomizer have teen investigated. Four atomizers with the different orifice diameter and five tangential ports with the different inlet number were fabricated. For the purpose of the measurement of the mean drop sine, Malvern particle sizer was used. And also discharge coefficient was measured and spray cone angle was measured by using shadow graphy method. As a result when the injection pressure was increased, mean drop size was decreased. And the dominant factor which influence on the spray characteristics of pressure swirl atomizer was orifice diameter.

  • PDF