• 제목/요약/키워드: Discharge Load Density

검색결과 32건 처리시간 0.023초

Design of the High Frequency Resonant Inverter for Corona Surface Processes

  • Choi, Chul-Yong;Lee, Dae-Sik
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.119-122
    • /
    • 2005
  • A algorithm for control and performance of a pulse-density-modulated (PDM) series-resonant voltage source inverter developed for corona-dischange precesses is presented. The PDM inverter produces either a square-wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant dc voltage and operating frequency. Moreover it can achieve zero-current-switching (ZCS) and zero-voltage-switching (ZVS) in all the operating condition for a reduction of switching lost. Even though the corona discharge load with a strong nonlinear characteristics, new high frequency resonant inverter is shown the wide range power control from 5% to 100%.

  • PDF

PPS시스템 이용 바이오디젤 혼합율에 따른 극미세입자 배출특성 비교 (Comparison of Nano-particle Emission Characteristics in CI Engine with Various Biodiesel Blending Rates by using PPS System)

  • 권지원;김민식;정명철;이진욱
    • 한국분무공학회지
    • /
    • 제17권3호
    • /
    • pp.134-139
    • /
    • 2012
  • The main purpose of this study is to analyze and compare the nano-particle emission characteristics by 3-different biodiesel blending rates in a CI engine. Nano-particle number density emitted from various operating conditions of compression ignition engine can be investigated by using the PPS (Pegasor Particle Sensor) system. Namely, some particle charged through the corona discharge in real-time can be measured by PPS system. Under the steady state operation of the 2.0L CRDi diesel engine with different operating condition and biodiesel blending rates, the nano-particle number density was analyzed at the downstream position of DOC system. As this research result, more engine load speed and higher the concentration of biodiesel blending rate showed that the nano-particle number density decreases. Also we found that DOC system for clean diesel engine is effectively useful instrument to reduce diesel particulate matter as resource of nano-particle generation.

A Novel Hybrid Supercapacitor Using a Graphite Cathode and a Niobium(V) Oxide Anode

  • Park, Gum-Jae;Kalpana, D.;Thapa, Arjun Kumar;Nakamura, Hiroyoshi;Lee, Yun-Sung;Yoshio, Masaki
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권4호
    • /
    • pp.817-820
    • /
    • 2009
  • To meet the high current load requirement from the high energy density realized by metal oxide and high power density graphite, we propose a novel hybrid supercapacitor consisting of Nb2O5 and KS6 graphite in 1.0 M LiPF6-EC:DEC (1:2). This new system exhibits a sloping voltage profile from 2.7 to 3.5 V during charging and presents a high operating voltage plateau between 1.5 and 3.5 V during discharging. The cell was tested at a current density of 100 mA/g with a cut-off voltage between 3.0 and 1.0 V. This novel energy storage system delivers the highest initial discharge capacity of 55 mAh/g and exhibits a good cycle performance.

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.

금호강, 남강 중권역 지류·지천의 상세오염 현황 및 오염기여율 조사 (Analysis of Specific Contaminated Status and Pollutant Loads Contribution Rate of the Tributaries in Gumho and Nam River Basin)

  • 나승민;권헌각;김경훈;신동석;임태효
    • 한국습지학회지
    • /
    • 제18권4호
    • /
    • pp.363-377
    • /
    • 2016
  • 본 연구는 낙동강수계 오염도가 높은 금호강 및 남강 중권역의 지천들 가운데 수질측정망과 일정한 거리에 있고 오염도가 높은 지천들을 선정하여 각 지점의 오염부하량, 오염특성, 중점관리지천별 세부 유입되는 지천의 오염현황 및 중점 지류가 낙동강 본류에 미치는 영향 등을 살펴보았다. 그 결과, 금호강 및 남강의 대부분의 수질항목별 오염도는 유사하였으나, TN, Chl-a 및 SS는 금호강이 남강에 비해 약 20~120% 이상 높은 오염도를 보였다. 오염발생부하율(kg/day) 및 발생밀도($kg/day/km^2$)는 유량과 하천유하면적에 따라 하천 오염도 순위가 달랐으며, 이러한 영향은 남강에서 더 크게 차이가 발생하였다. 금호강 및 남강의 상세오염조사는 하천의 유로길이, 합류되는 소하천의 개수와 형태에 따라 상세지점을 2개에서 최대 9개까지 나누어 조사하였으며, 그 결과 달서천과 의령천의 오염도가 높게 나타났다. 이외에도, 달서천과 의령천의 본류오염 기여율이 약 10% 내외로 높게 나타났으며, 이는 주변공단, 생활거주지역 형태 및 크기, 농경지 경작 유 무 및 축사 존재 유 무에 따라 오염도 및 상 하류 오염형태가 다르기 때문으로 판단된다

The KSTAR Vacuum Pumping and Fueling System Upgrade

  • Lim, J.Y.;Chung, K.H.;Cho, S.Y.;Lee, S.K.;Shin, Y.H.;Hong, S.S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.39-39
    • /
    • 1999
  • The KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak is a nuclear fusion experimental device for a long pulse/steady-state plasma operation, adopting fully superconducting magnets. In accordance with completion of the basic design of the torus vacuum vessel and the enclosing cryostat, the vacuum pumping and gas fueling basic design has been developed to fulfil the physics requirements. The ultra-high vacuum pumping and sophisticated gas fueling system of the machine is essential to achieve such roles for optimized plasma performance and operation. Recently the vacuum exhaust system using dedicated pumping ports for the vacuum vessel and cryostat has been modified to meet more reliable and successful performance of the KSTAR[Fig. 1].In order to achieve the required base pressure of 5 x 10-9 torr, the total impurity load to the vessel internal is limited to ~5 x 10-5 torr-1/x, while the cryostat base pressure is kept as ~5 x 105 torr to mitigate the thermal load applied to the superconducting magnets. Each KSTAR fueling system will be separately capable of fueling gas at a rate of 50 torr-1/x, consistent with the given pumping throughput. In order to initiate a plasma discharge in KSTAR, the vacuum vessel is filled to a gas pressure of few 10-6 to few 10-4 torr, and additional gas injection is required to maintain and increase the plasma density during the course of the discharge period.

  • PDF

황구지천 유역의 오염부하 특성 및 지류 영향 평가 (Evaluation on Pollution Load Characteristics and Influence of Tributaries in the Hwangguji Stream)

  • 임수진;임병란;이한샘;강주형;안태웅;신현상
    • 한국물환경학회지
    • /
    • 제37권4호
    • /
    • pp.249-262
    • /
    • 2021
  • This study investigated the pollution characteristics of the main pollution zone in the Hwangguji watershed and the influence of the tributary on the main stream. The characteristics of the main pollution zone, including, the water quality index (WQI), stream rating, load duration curve (LDC), delivery load density (DLD), and contribution of the tributary to the mainstream, were evaluated by time-series visual heatmap. The WQI of the mainstream of Hwangguji was lowered to the poor (IV) level from the inflow point of Suwon stream (SW) and the LDC excess rate in the T-P was higher than that of BOD5, especially for the wet season, suggesting that management of non-point source with T-P is preferred. The contribution (%) of the tributaries in the upstream section of Hwangguji watershed were BOD5 14.54%, TOC 15.67%, T-N 5.43%, and T-P 6.97%. In particular, the Suwon sewage treatment plant located in the mainstream showed a high contribution of BOD5 (64.40%) and T-P (53.54%), respectively, due to the high discharge rate (6.019 m3/sec). Meanwhile, Sammi and Gal stream have a large impact on the mainstream with high DLD and poor WQI. Thus, both streams were considered as pollution hot spots. These results provide useful basic data for preparing more effective water quality improvement and management plans in the watershed.

MATLAB/Simulink를 이용한 오프그리드형 고효율 태양광 충전 시스템 설계 (Design of an Off Grid type High efficiency Solar charging system Using MATLAB/Simulink)

  • 미흐렛 가아브레슬라세 마루;김민;변기식;김관형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.735-737
    • /
    • 2017
  • An Off grid or remote solar electric systems are an energy supply to our home or to our companies without the utility of Grid at all. Off grid solar systems are very important for those who live in remote locations especially for developing countries where getting the electric grid is extremely expensive, inconvenient or for those who doesn't need to pay a monthly bill with the electric bill in general. The main critical components of any solar power system or renewable energy harvesting systems are the energy storage systems and its charge controller system. Energy storage systems are the essential integral part of a solar energy harvesting system and in general for all renewable energy harvesting systems. To provide an optimal solution of both high power density and high energy density at the same time we have to use hybrid energy storage systems (HESS), that combine two or more energy storage technologies with complementary characteristics. In this present work, design and simulation we use two storage systems supercapacitor for high power density and lithium based battery for high energy density. Here the system incorporates fast-response supercapacitors to provide power to manage solar smoothing and uses a battery for load shifting. On this paper discuss that the total energy throughout of the battery is much reduced and the typical thermal stresses caused by high discharge rate responses are mitigated by integrating supercapacitors with the battery storage system. In addition of the above discussion the off grid solar electric energy harvesting presented in this research paper includes battery and supercapacitor management system, MPPT (maximum power point tracking) system and back/boost convertors. On this present work the entire model of off grid electric energy harvesting system and all other functional blocks of that system is implemented in MATLAB Simulink.

  • PDF

소옥천 유역 비점오염 관리를 위한 취약성 지수분석 및 평가에 관한 연구 (A Study on the Analysis and Evaluation of Vulnerability Index for the Management of Nonpoint source in SoOak River Watershed)

  • 갈병석;문현생;홍선화;박천동;길한뉘;박재범
    • 한국지리정보학회지
    • /
    • 제22권2호
    • /
    • pp.107-120
    • /
    • 2019
  • 본 연구에서는 대청호 상류에 위치한 소옥천을 대상으로 유역 및 오염원 특성을 조사하여 각 특성별 지수를 분석하고 취약지역을 분석하였다. 다양한 유역 및 오염원 자료를 지수화하기 위하여 표준화법인 Dimension Index법을 적용하였으며 선정된 지수와 수질모니터링 자료와의 상관성 분석을 통해 각 오염원별 영향인자를 도출하였다. 오염원별 영향인자에 미치는 특성들은 각각의 유의성에 차이가 있었으며 BOD와 COD는 인구밀도와 대지면적 비율, T-N은 CN과 논면적 비율, T-P는 인구밀도와 대지면적 비율에서 유의한 영향이 있는 것으로 검토되었다. 오염원별 영향인자로 판단된 지수를 이용하여 취약지역 우선순위를 산정하였고 배출부하량을 고려하여 산정된 취약지역과 순위를 비교 검토하였다. 배출부하량은 비점오염 대책 수립시 많이 사용되고 있으나 호소나 하천에 유입되는 유달부하량과 차이가 있어 수질 모니터링 자료와의 상관성 분석시 수질과 유의미한 값이 낮게 나타났다. 따라서 효율적인 비점오염 관리를 위해서는 취약지역 선정과 함께 수질과 상관성 높은 영향인자를 분석하고 해당 인자에 대한 관리가 우선으로 필요할 것으로 판단된다.

전기이중층커패시터의 가속열화시험 (An Accelerated Degradation Test of Electric Double-Layer Capacitors)

  • 정재한;김명수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권2호
    • /
    • pp.67-78
    • /
    • 2012
  • An electric double-layer capacitor(EDLC) is an electrochemical capacitor with relatively high energy density, typically hundreds of times greater than conventional electrolytic capacitors. EDLCs are widely used for energy storage rather than as general-purpose circuit components. They have a variety of commercial applications, notably in energy smoothing and momentary-load devices, and energy-storage and kinetic energy recovery system devices used in vehicles, etc. This paper presents an accelerated degradation test of an EDLC with rated voltage 2.7V, capacitance 100F, and usage temperature $-40^{\circ}C{\sim}65^{\circ}C$. The EDLCs are tested at $50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$, respectively for 1,750hours, and their capacitances are measured at predetermined times by constant current discharge method. The failure times are predicted from their capacitance deterioration patterns, where the failure is defined as 30% capacitance decrease from the initial one. It is assumed that the lifetime distribution of EDLC follows Weibull and Arrhenius life-stress relationship holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.