• 제목/요약/키워드: Discharge Intensity

검색결과 354건 처리시간 0.026초

히터 일체형 하이브리드 단판형 플라즈마 방전소자 (One-Plate Type Hybrid Plasma Discharge Device with Heating Element)

  • 최우진;최은혜;성형석;권진구;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.320-326
    • /
    • 2019
  • Recently, the application of atmospheric plasma technology in air filtration is increasing. Sterilization by an atmospheric plasma device is very effective. However, ozone gas, which is generated during atmospheric plasma formation, poses a hazard to human health. To reduce the ozone gas during plasma discharge, we fabricated a one-plate hybrid plasma discharge device with a heating element, which can decompose ozone gas effectively by a simple heating action. In this study, we evaluated the plasma discharge characteristics and ozone concentrations with various Ar flow rates and temperatures. With increasing Ar gas flow rate, the ozone concentration and spectrum intensity increased till an Ar gas flow rate of 60 sccm, and decreased thereafter. When discharged in high temperature, the ozone concentration and spectrum intensity decreased. Further, to evaluate the state of the treated surface under various plasma discharge and heating conditions, we measured the variation in the contact angles on the surface. Regardless of the temperature, the contact angle increased with increasing discharge voltage. However, the contact angle increased when discharged at high temperature.

레이저 펌핑용 Xe-flashlamp 의 방전 특성 (Discharge Characteristics of Xe-flashlamp for Laser pumping)

  • 최면숙;오철한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.409-410
    • /
    • 1989
  • Discharge characteristics of a commercial made Xe-flashlamp have been studied for the pumping source of dye Lasers. The rise-time, FWHM, intensity and energy of pumping light pulses of the lamp were measured as functions of the serial resistor and applied voltage. The grid effects of the lamp on pre-discharge and the spectrum of light pulses also have been investigated.

  • PDF

UV emission characteristics of Ne+$N_2$ gas-mixture discharges in AC Plasma Display Panel

  • Baek, Byung-Jong;Hong, Sang-Min;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.586-589
    • /
    • 2002
  • The Ultra Violet(UV) emission characteristics of Neon + Nitrogen gas-mixture discharge was investigated in AC plasma display panel. The firing voltage of Ne+$N_2$ gas-mixture discharge increased with increasing nitrogen concentration. The UV intensity emitted from the gas discharge also increased with increasing nitrogen concentration. The UV efficiency increase with increasing $N_2$ partial pressure at low $N_2$ concentration, and then UV efficiency is saturated at high $N_2$ concentration.

  • PDF

Toward Efficacy Improvement in a PDP Discharge Cell from Structural Considerations

  • Tachibana, Kunihide
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.20-23
    • /
    • 2009
  • The efficacy improvement issues in a unit discharge cell have been approached from the structural considerations. The tested cell designs include (a) a coplanar type with annular auxiliary electrode buried in barrier ribs, (b) a coplanar type with split auxiliary electrodes also burred in barrier ribs and (c) a coaxial type with a floating electrode stacked on the base electrode. From spatiotemporally resolved optical images of near-IR emission taken by a gated-ICCD camera and relative VUV emission intensity estimated by laser absorption spectroscopy, the differences in the discharge and light emission performances of those three cell types have been compared and discussed.

  • PDF

SF_6 가스와 절연지의 절연계에서 가스압력에 따른 부분방전현상 (Partial Discharge Phenomenon with $SF_6$ Gas Pressures in Insulation consisting of Insulation Paper and $SF_6$ Gas)

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.65-71
    • /
    • 2001
  • This paper describes partial discharge phenomenon with SF6gas pressures in insulation consisting of insulation paper and SF6 gas. We made the specimens with SF6 gas gaps which exist between aramid papers and electrodes and calculated the electric field intensity in the these gaps. We measured the partial discharge inception voltages and the AC breakdown voltages with the test method of IEC 60060-2 and did the partial discharge degradation experiments with a constant voltage. According to gas pressures, the breakdown voltages in SF6gas gaps were calculated by Paschen's law. And these results showed the ability applying partial discharge inception voltages evaluation to Paschen's law and the relationship between the PD quantities occurring insulation breakdown and PD occurring area.

  • PDF

교류형 플라즈마 표시기의 신 대향형 구조에 대한 방전 특성 분석 (Analysis on the Discharge Characteristics of AC Plasma Display Panel with Counter Sustain Electrodes)

  • 배현숙;황기웅
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1579-1583
    • /
    • 2008
  • We proposed the new structure of ac plasma display panel(PDP) to improve the luminous efficacy and driving voltage characteristics. Through two-dimensional numerical simulations, we analyzed the effects of new counter discharge type, which consists of counter sustain electrodes and auxiliary electrodes. Generally, an advantage of AC PDP with the counter sustain electrodes has been known for the driving characteristics of the low voltage. In this work, the new counter structure using the ignition discharge by the auxiliary pulse applied to the address electrode showed the result of the increased luminous efficacy. The short gap discharge between two auxiliary electrodes on the front plate could intensity the long gap discharge between counter electrodes. The reliability of simulation result could be confirmed by the experimental result in the test panel.

광학적인 방법에 의한 플라즈마 디스플레이 패널의 3차원 광 방출 측정과 분석 (The Measurement and Analysis of Three-Dimensional Light Emitted from Plasma Disp1ay Panel by Optica1 Method)

  • 최훈영;이석현;이승걸
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권1호
    • /
    • pp.31-38
    • /
    • 2002
  • We measured a 3-dimensional images of the light emitted from plasma display panel(PDP) by using newly proposed scanned point detecting system. In the panel without phosphor, as we scan from the rear glass to the front glass, the detected light intensity increases and the light intensity detected in the inside edge of the ITO electrodes shows the stronger intensity than others. The light intensity detected between the barrier ribs shows the largest value of brightness. Also, as the sustain voltage increases, the detected light intensity increases. In the panel with phosphor, the intensity of light detected at barrier rib shows the stronger light intensity than rear plate. Therefore, the phosphor of barrier rib is very important. From these results the 3-dimensional measurement is necessary to understand exactly the discharge phenomenon in the PDP cell.

핀이 부착된 와이어형 방전극의 형상에 따른 코로나 방전특성에 대한 연구 (Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries)

  • 정성일;이재근;정동규;안영철
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.95-100
    • /
    • 2006
  • Electrostatic precipitators(EPs) have low pressure drop and high dust collection efficiency and are widely used for industrial dust collectors. The current-voltage characteristics, which are important to maintain high dust collection efficiency, depend on several factor: discharge electrode shape, gas flow property, dust loading etc. In this study, experiments are performed to investigate the current-voltage characteristics of the corona discharge of various electrode geometries and an empirical model is proposed to predict current-voltage characteristics of the corona discharge. The corona onset voltage correction coefficient$(\alpha)$ and the geometry correction coefficient$(k_g)$ are used to the conventional equation for wire-plate type discharge electrode. The corona onset voltages are -6.3kV and almost constant when the numbers of discharge pins are varied from 3 to 9. The length of discharge pins has very sensitive effects on the corona onset voltage. They are increased from -6.3 to -7.8kV when the discharge pin length are 8.5 and 4.5mm, respectively. The empirical model shows good agreement with experimental results and can predict the effects of discharge pin length and number.

도시유역의 내수배제를 위한 도시유출모델의 비교 (Comparison of Urban Runoff Models for Interior Drainage in Urban Basin)

  • 최윤영;이영화;지홍기
    • 상하수도학회지
    • /
    • 제14권3호
    • /
    • pp.251-259
    • /
    • 2000
  • In this study, the urban runoff models, ILLUDAS model and SWMM, are analyzed the probable peak discharge and discharge using rainfall distribution by Huff's method at Bum-uh chun area in Taegu city. The probability rainfall and intensity is analyzed by Pearson-III type. The rainfall duration, 90 minutes, is determined by the critical duration computed the maximun peak discharge for some rainfall durations. The peak discharge according to Huff's rainfall distribution types compute in order of type 3, type 4, type2, and type 1, so Huff's 3 type is selected as an adequate rainfall distribution in Bum-uh chun basin. ILLUDAS model and SWMM are shown as good models in Bum-uh chun, but SWMM is computed higher peak discharge than ILLUDAS model, so SWMM is shown as the adequate urban runoff model for the design of interior drainage in urban basin.

  • PDF

Auto-Leveling of HID Headlamp Using Preview Control

  • Yang, Boojoong;Kang, Heeyong;Yang, Sungmo
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1404-1411
    • /
    • 2002
  • A newly developed high intensity discharge (HID) automotive headlamp results in a high luminous gradient at the cutoff line, and proves the superior concept in safer and more com-fortable nighttime driving. This new headlamp technology Provides drivers expanded night vision by a significantly improved light pattern. However, the HID headlamp may dazzle other traffics during traversing a rough road or encountering an unexpected bump. To resolve this problem, an automatic headlamp leveling device is necessary. A preview control is presented for the design of the leveling system. The proposed control algorithm is capable of attenuating a dynamic glare which is one of the major detractors to a driving in dark roads. Computer simulations using ADAMS are carried out to confirm the effectiveness on the control system.