• 제목/요약/키워드: Discharge Input Power

검색결과 157건 처리시간 0.03초

태양광/연료전지용 배터리 충·방전 하이브리드 시스템 설계 (Design of Hybrid System for Battery Charge·Discharge using Photovoltaic/Fuel cell)

  • 박봉희;조영민;최주엽;조상윤;최익;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.123-129
    • /
    • 2014
  • Photovoltaic and fuel cell systems can be used as power source in mobile robots. At this time the photovoltaic system generally generate power in daytime. The starting time of fuel cell is slower than the lithium battery. To compensate for these disadvantages, a battery charge-discharge system is used. Especially the bi-directional converter is used mainly in the charge-discharge method. The controller in a buck converter controls the input voltage of the converter to meet the maximum power point tracking(MPPT) performance. First of all, the simulations of hybrid system for battery charge-discharge system in each step simulated using solar and fuel cell modeling as input source in PSIM. Experiment of the buck and bi-directional converter system is conducted through using photovoltaic/fuel cel simulator(pCube) instead of solar and fuel cell. This hybrid system for battery charge discharge using photovoltaic/fuel cell generates emergency power for the communication system in mobile robot.

환경개선을 위한 형광방전등형 오존발생기의 특성 (Characteristics of Fluorescent Discharge Lamp Type Ozonizer for Environment Improvement)

  • 박용권;이상근;전병준;송현직;이광식;하장호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.500-505
    • /
    • 2002
  • In this paper, fluorescent discharge type ozonizer has been designed and manufactured. Ozone discharge and generation characteristics have been investigated in accordance with a sort of internal electrodes, output voltage of power supply, air flow rate and discharge power. Air has been used as the supplied gas of the ozonizer In this paper, when disuse fluorescent lamp was used as an internal electrode. Air flow rate was varied from 2[1/min] to 10[1/min]. The maximum ozone concentration and yield were 3495[ppm] and 23.4[g/kWh] respectively at 2[1/min] air flow rate and 35.2[W] input power. Illumination was appeared as 5[lx] within 15[cm] from external electrode. Whorl fluorescent discharge type ozonizer was used, air flow rate was also varied from 2[1/min] to 10[1/min]. At this moment, the maximum ozone concentration and yield were 2824[ppm] and 21.7[g/kWh] respectively at 2[1/min] air flow rate and 30.5[W] input power. Illumination was also appeared as 5[lx] within 15[cm] from external electrode like used fluorescent lamp.

고전압 방전을 이용한 수질분식에 관한 특성 (A Characteristics on Water Quality Analysis Used the High-Voltage Discharge)

  • 조국희;김영배;조문수
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.156-161
    • /
    • 2004
  • 본 논문은 수질 오염 항목의 대표격인 대장균 제거를 위해 고전압 펄스 전원과 직류 전원을 비드(SiO$_2$, $Al_2$O$_3$, ZrO$_2$)가 없는 방전관, 비드가 있는 방전관, 그리고 수중 방전관에 사용하였다. 실험 결과에 따르면 대장균 제거 특성은 입력 전압의 비에 따라 나타났는데, 이는 입력전압이 증가할 때 방전관내의 전계영역이 같이 증가하기 때문이다. 그리고 고전압 펄스 전원을 사용했을 때 지르코니아(ZrO$_2$) 비드 방전관이 다른 방전관들보다 우수하였으며, 직류전원을 사용한 수중 방전관이 고전압 펄스를 사용한 방전관들보다 수중 대장균 제거 특성이 우수한 결과를 보였다.

플라즈마 발생장치용 공진형 인버터 전력변환장치 (A Resonant Type Inverter Power Conversion Equipment for Plasma Generator)

  • 김주용;서기영;문상필;정장근;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균용 전원장치에 관한 연구 (A study on power system for plasma sterilization)

  • 강욱중;김영문;문상필;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.52-54
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described, For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc.. PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템 (Resonance inverter power system for plasma sterilization effective improvement)

  • 김주용;문상필;김종실;김영문;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균 효과 향상을 위한 공전형 전원 시스템 (Resonance Inverter Power System for Sterilization Effective Improvement of Plasma)

  • 김주용;문상필;정장근;이현우;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

오신호 입력에 따른 펌프의 고장징후 조기감지 성능분석 (Performance Analysis on Early Detection of Fault Symptom of a Pump with Abnormal Signals)

  • 정재영;이병오;김형균;김대웅
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.66-72
    • /
    • 2016
  • As a method to improve the equipment reliability, early warning researches that can be detected fault symptom of an equipment at an early stage are being performed out among developed countries. In this paper, when abnormal signal is input to actual normal signal of a pump, early detection studies on pump's fault symptom were carried out with auto-associative kernel regression as an advanced pattern recognition algorithm. From analysis, correlations among power of motor driving pump, discharge flow of pump, power output of pump, and discharge pressure of pump are exited. When the abnormal signal is input to one of those normal signals, the other expected values are changed due to the influence of the abnormal signal. Therefore, the fault symptom of pump through the early-warning index is able to detect at an early stage.

디젤엔진용 코로나 방전식 전기집진장치의 개발 과정에서의 배기 정화 성능에 관한 기초연구 (A Study on the Performances of Exhaust Gas Purification at Process on the Development of Corona Discharge Type Electrostatic Precipitator for Diesel Engines)

  • 손병호;배종욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.904-910
    • /
    • 2007
  • In this study an experimental research has been conducted to reduce NOx and smoke emission from diesel engine exhaust gas simultaneously by application of corona discharge type electrostatic precipitator(ESP). The ESP was installed between exhaust gas silencer and outlet terminal of exhaust gas system. The operating conditions as input parameters taken in this experiment were corona power input, gas velocity and equivalence ratio of gas. It was found that the corona discharge type ESP has notable effect on reducing smoke in exhaust gas but appeared to bring slight effect on reducing NOx.

전극 형태에 따른 평판형 오존발생기의 특성 (The Characteristics of Plate Type Ozonizer with Variation of Electrode Form)

  • 윤병한;이창호;우성훈;이광식
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.149-156
    • /
    • 2008
  • 최근 오존은 그 활용성을 인정받아 다양한 분야에서 사용되고 있으며, 그 수요 또한 계속 증가하는 추세이다. 이에 다양한 종류의 오존발생기가 연구되고 있으며, 고농도 및 고수율을 얻는 것이 연구목표라 할 수 있다. 본 논문에서는 전극 형태에 따른 평판형 오존발생기를 제작하여 원료가스의 유량 및 방전전력의 변화에 의한 오존생성농도, 오존생성량 및 오존생성수율 특성을 연구하였다.