• Title/Summary/Keyword: Discharge Impact Analysis

Search Result 174, Processing Time 0.022 seconds

Flow Structure Interaction 3-D Reciprocating Compressor and Impact Analyses of Compressor Discharge Valve (압축기 토출벨브의 유체-구조 연계해석 및 충돌해석)

  • Octavianty, Ressa;Kim, Dong-Hyun;Park, Kang-Gyun;Jung, Won-Hyun;Ahn, Jae-Woo;Moon, Kyeong-Ho;Ko, Young-Pil;Kim, Hyeong-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.633-640
    • /
    • 2007
  • In this paper, 3-D reciprocating compressor is taken into flow-structure interaction analysis. The full cycle process consisted of cylinder expansion and compression has been modeled without considering flow leakage through cylinder wall. Fully-coupled FSI analysis of this compressor model was iteratively solved and gives sufficient result with the experimental test. The study is emphasized to thoroughly investigate discharge valve motion, opening and closing, in order to determine discharge valve region which is prone to have high effective stress. The cylinder pressure is successfully validated before conducting impact analyses between discharge valve and other susceptible supported structure. Velocity profile has been obtained in FSI analysis is used as initial condition to carry out further impact analyses. Stress result of discharge valve and valve spring gives preliminary estimation of higher stress area due to its impact phenomena.

  • PDF

Dynamic Analysis of a Discharge Valve for Electrodynamic Oscillating Compressor (전동형 진동식 압축기 토출밸브의 동적해석)

  • 김형진;박윤식
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.615-622
    • /
    • 2000
  • Discharge valve mechanism for an electrodynamic-oscillating compressor is different from that of a conventional reciprocating compressor. It has a larger discharge port area, heavier valve mass and stiffer valve spring comparing with the reciprocating one. Since the motion of piston is not kinematically restricted as in conventional reciprocating compressors, the stroke of the piston can change sensitively with supplied boltage and load. Thus piston can impact with discharge valve occasionally. This work deals on dynamic analysis of discharge valve considering all of those different characteristics. Impact is considered by a spring-mass model, and the pressure fluctuation at the both sides of the valve is also included considering the discharge port area and valve spring preload. It is assumed that piston moves in the region of between top and bottom dead center not by calculating piston motion from an electrodynamic equation but by getting values through experiment. Discharge pressure fluctuation is calculated using Helmholtz modeling. Finally, dynamic model for a discharge valve is constructed. In order to validate the model analysis results, the valve motion is experimentally measured and compared with analysis.

  • PDF

Water Quality Impact Assessment in Korea - Comparing with the Integrated Control of Pollutant-Discharging Facilities - (수질분야 환경영향평가의 개선방안 - 환경오염시설의 통합관리와 대비하여 -)

  • Lee, Jong Ho;Cho, Jae Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.5
    • /
    • pp.331-343
    • /
    • 2017
  • The important changes in water environment management in Korea can be summarized as the enactment of Act on the Integrated Control of Pollutant-Discharging Facilities. Therefore water quality impact assessment should be reexamined and be revised. This study examines the present water quality impact assessment items (permissible discharge limits, standards for effluent water quality including Total Pollutant Load Management System) and considers the land use regulation for water quality conservation and NVZs(Nitrate Vulnerable Zones of EU and England). It also considers lately adopted standards(maximum discharge standards, permissible discharge standards, and marginal discharge standards etc) based on Act on the Integrated Control of Pollutant-Discharging Facilities and then compares Korean BAT and its counterpart control technology of U.S.A. And it also compares the items of water quality impact assessment with those of Integrated Control of Pollutant-Discharging Facilities, based on EIS reporting items. This study suggests five improvement measures for water quality impact assessment. First reflection of discharge impact analysis on impact prediction and assessment, second reflection of permissible discharge standards on agreed standards in the EIA procedure, third, reflection of diversified BAT on mitigation measures in the EIA procedure, forth introduction of land use regulation such as NVZs, finally strengthening linkage between water quality items and land use items etc.

A Stochastic Analysis of the Water Quality with Discharge Variation in Upper Nakdong River Basin (낙동강 상류 유역에서의 유량변동에 따른 수질의 통계학적 분석)

  • Choi, Hyun Gu;Han, Kun Yeun;Choi, Seung Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.833-843
    • /
    • 2011
  • The purpose of this study is to analysis pollutant loading of upper Nakdong River basin according to the variation of discharge. The correlation between discharge and pollutant concentration and between discharge and pollutant loading were analyzed by statistical method, respectively. Regression equation of pollutant loading and discharge was represented as $L=_aQ^b$ in which L = pollutant loading(kg/day), and b = regression coefficients, and Q = discharge($m^3/day$). The correlation coefficient of study area was in range of 0.8428 to 0.9935. The SS was the highest b value 1.2856~1.7730 among water quality parameters because the pollutant loading of SS was much affected by flow. Additionally, the applicability of the regression equations was verified by comparing predicted results with observed value. The correlation coefficient of verification was in range of 0.8983 to 0.9987 and NSEC was in range of 0.7018 to 0.9960. Therefore the pollutant loading was good correlated with discharge. The main result will be used as basic data for water quality management and design of environment fundamental facilities.

Modification of Discharge Mechanism of Binder Harvesters (바인더수확기(收穫期)의 방출구조(放出構造) 개선(改善)에 관한 연구(硏究))

  • Park, Keum Joo;Chung, Chang Joo;Ryu, Kwan Hee
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.26-38
    • /
    • 1983
  • Binder harvesters introduced to Korea were originally designed to be used for Japonica varieties which are highly resistant to shattering. In order to improve the performance of the binder to Indica varieties which are easily shattered and have shorter stem, mechanical modifications of the binder are inevitable. Shattering losses of the binder can be classified into two major parts; one incurred before and one after binding operations. The latter has been evaluated as great as the former. Previous studies indicated that the high discharge losses resulted from a great impact force of the discharge arm on the rice bundle during the discharge process. This study was intended to theoretically analyze the discharge mechanism of four-bar linkage. For this purpose, two commercially available binder harvesters having a four-bar linkage as a discharge mechanism were analyzed. Using the results from the motion analysis and the other structural constraints of the machines, they were modified and experimentally compared with the machines without modification to see whether any decrease in grain losses was obtained. The results obtained in this study are summarized as follows: 1. The path, velocity and acceleration of discharge arm were computer analyzed by vector analysis. Using results of the analysis and intrinsic constraints of the binder, discharge mechanism was modified to reduce the impact force on bundle by discharge arm in the range where the discharge performance was not deteriorated. This modification of the discharge mechanism could be done with an aid of four-bar linkage synthesis technique. As a result, average velocity and acceleration of the discharge arm during the discharge process were reduced respectively by 19 percent and 33 percent for binder A, and 17 percent and 35 percent for binder B. 2. Through the modification of the discharge mechanism, discharge losses of binder A were reduced by 42-56 percent for Milyang 23, Poongsan and Hangang chal, and discharge losses of binder B were reduced by 13-20 percent for Milyang 23 and Poongsan. 3. Discharge losses were decreased as the bundle size became larger and the size effect on the decrease rate appeared more significant in the binders with modifications than in those without modifications.

  • PDF

The Analysis of Runoff Characteristics by Alterations of SCS-CN Value using LID Method (LID 기법 적용에 의한 SCS-CN값 변화가 강우유출특성에 미치는 영향 분석)

  • Kwon, Jun-Hee;Park, In-Hyeok;Ha, Sung-Ryoung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.49-57
    • /
    • 2010
  • The objective of the research is to analyze changing trend of water discharge in precipitation, according to changing land use, through an environment-friendly urban development method called LID. The study chose S1 basin (Separated Sewer districts) in Cheongju region for survey. Among LID methods, relatively more applicable methods of green rooftop space and parking lot with permeable material were selected to construct plausible scenarios. Curve Number (CN) value was calculated due to land use patterns in each scenario, and SWMM model simulation were conducted during 2008 for comparative analysis. For Case 1, only parking lot with permeable material was applied to the scenario. Green rooftop space I and II were applied to Case 2 and 3 respectively. For Case 4 and 5, green rooftop space I and II were applied, in addition to parking lot with permeable material, Calculation of CN value showed that for S1 basin, the value was 88.1 (prior to scenario application), 86.5 (Case 1), 81.9 (Case 2), 68.5 (Case 3), 80.4 (Case 4) and 67.2 (Case 5). Changing pattern of rain water discharge was analyzed for each scenario. For Case 1, the change was not remarkable before and after application of scenario. In Case 2 and 4, the impact of rain water discharge as source of pollutant fell to 20~30%. The rate dropped to 30~50% in Case 3 and 5 respectively. The result demonstrates that the amount of rain water discharge, amount and frequency of sewer overflow, frequency of rain water discharge, and pollution load decreased in accordance with declining CN value in each scenario. In installing green rooftop space, the effect was twice greater when rain water discharge was directly infiltrated into soil.

A Study on the Improvement of the Road Traffic Noise Prediction for Environmental Impact Assessment (환경영향평가시 도로교통소음예측에 관한 개선방안 연구)

  • Lee, Nae-Hyun;Park, Young-Min;Sunwoo, Young
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.4
    • /
    • pp.297-304
    • /
    • 2001
  • Recently the road traffic noise has appeared as a significant environmental issue because of dramatic increase of vehicles and expansion of newly constructed road. Therefore, this study proposes the method that improves prediction factors and models through analysis of the existing road traffic noise prediction model. Prediction factors can be improved by establishing guideline for diffraction attenuation and applying daily traffic discharge, peak traffic discharge, and average traveling speed through an analysis of level service. Prediction must be made by periods of one or five years during 20 years. Prediction models also can be improved to include better prediction model through setting the database, establishing functional relation between physical properties and noise levels by acoustic analysis, and developing models for road traffic noise prediction in residential areas.

  • PDF

Numerical Analysis on the Discharge Characteristics of a Liquid Rocket Engine Injector Orifice

  • Cho, Won-Kook;Kim, Young-Mog
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • A numerical analysis was performed on the fluid flow in injector orifice of a liquid rocket engine. The present computational code was verified against the published data for turbulent flow in a pipe with a sudden expansion-contraction. Considered were the parameters for the flow analysis in an injector orifice: Reynolds number, ratio of mass flow rate of the injector orifice and inlet flow rate, and slant angle of the injector orifice. The discharge coefficient increased slightly as the Reynolds number increased. The slant angle of the injector changed critically the discharge coefficient. The discharge coefficient increased by 7% when the slant angle changed from $-30^{\circ}$ to $30^{\circ}$ The ratio of mass flow rate had relatively little impact on the discharge coefficient.

A Multilevel Analysis about the Impact of Patient's Willingness for Discharge on Successful Discharge from Long-term Care Hospitals (퇴원 의지가 요양병원의 성공적 퇴원에 미치는 영향에 대한 다수준 분석)

  • Ghang, Haryeom;Lee, Yeonju
    • Health Policy and Management
    • /
    • v.32 no.4
    • /
    • pp.347-355
    • /
    • 2022
  • Background: Since November 2019, long-term care hospitals have been able to provide patients with discharging programs to support the elderly in the community. This study aimed to identify both patient- and hospital-level factors that affect successful community discharge from long-term care hospitals. Methods: A multilevel logistic regression model was performed using hospitals as a clustering unit. The dependent variable was whether a patient stayed in the community for at least 30 days after discharge from a long-term care hospital. As for the patient-level independent variables, an agreement between a patient and the family about discharge, length of hospital stay, patient category, and residence at discharge were included. The number of beds and the ratio of long-stay patients were selected for the hospital-level factors. The sample size was 1,428 patients enrolled in the discharging program from November 2019 to December 2020. Results: The number of patients who were discharged to the community and stayed at least for 30 days was 532 (37.3%). The intraclass correlation coefficient was 22.9%, indicating that hospital-level factors had a significant impact on successful community discharge. The odds ratio (OR) of successful community discharge increased by 1.842 times when the patients and their families agreed on discharge. The ORs also increased by 3.020 or 2.681 times, respectively when the patients planned to discharge to their own house or their child's house compared to those who didn't have a plan for residence at discharge. The ORs increased by 1.922 or 2.250 times when the hospitals were owned by corporate or private property compared to publicly owned hospitals. The ORs decreased by 0.602 or 0.520 times when the hospital was sized over 400 beds or located in small and medium-sized cities compared to less than 200 bedded hospitals or located in metropolitan cities. Conclusion: The results of the study showed that the patients' and their family's willingness for discharge had a great impact on successful community discharge and the hospital-level factors played a significant role in it. Therefore, it is important to acknowledge and support long-term care hospitals to involve active in the patient discharge planning process.

The Study on the Improvement of Environmental Assessment Method through Analysis of Environmental Investigation Results of Taean Thermal Power Plant (환경영향평가와 사후환경조사의 비교에 관한 연구 - 태안화력발전소 사례분석 -)

  • Chun, Sang-Ki;Lee, Sung-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.61-74
    • /
    • 2000
  • This study compares the results of environmental impact assessment with the results of post-environmental investigation, using the case of Taean thermal power plant construction. The atmospheric and water qualities were not greatly changed before and after the construction of the power plant. However, the site of the highest concentration predicted by the atmospheric quality modeling in environmental impact assessment was different from that after operation of 4 power plants. There was also a difference in the diffusion range of thermal discharge water between the measured result(1km) and the predicted value(1.5km) with the model. Thus, environmental impact evaluation should be based on long-term (more than a year) environmental monitoring data. For the modeling of atmospheric quality and numerical thermal discharge water diffusion, appropriate models for each plant should be selected and the numerical modeling should be accompanied by computer simulation, wind tunnel test, etc. Moreover, environmental evaluation should focus more on the degree of impact on surroundings than the prediction of changes in surroundings caused by operation of plants.

  • PDF