• Title/Summary/Keyword: Discharge Control

Search Result 1,425, Processing Time 0.031 seconds

Association between defoliant exposure and survival to discharge after out-of-hospital cardiac arrest (고엽제 노출과 병원 밖 심정지 후 생존 퇴원과의 연관성)

  • Kim, Dong Wook;Kye, Yu Chan;Lee, Jung Youp;Jung, Eui Gi;Kim, Dong Sung;Choi, Hyun Jung;Lee, Young
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.1
    • /
    • pp.38-43
    • /
    • 2021
  • Purpose: We investigated the association between defoliant exposure and survival to discharge after out-of-hospital cardiac arrest. Methods: This is a retrospective case-control study based on the cardiopulmonary resuscitation (CPR) registry. The electronic medical records of out-of-hospital cardiac arrest victims from 6/9/2008 to 12/31/2016 were analyzed statistically. The case patients group had a history of defoliant exposure while the control group did not. Among the 401 victims studied, a total of 110 patients were male out-of-hospital cardiac arrest patients. Baseline characteristics and the parameters involved in cardiac arrest were analyzed and compared between the two groups after propensity score matching. The primary outcome was survival to discharge, and secondary outcomes were sustained return of spontaneous circulation (ROSC) and survival to admission. Results: After propensity score matching a total of 50 patients (case=25, control=25) were analyzed. Primary outcome (survival to discharge) was not significantly different between case and control groups [(OR, 1.759; 95% C.I., 0.491-6.309) and (OR, 1.842; 95% C.I., 0.515-6.593), respectively]. In the subgroup analysis, there were also no significant differences between the control group and subgroups in primary and secondary outcomes according to defoliant exposure severity. Conclusion: There is no statistically significant association between defoliant exposure and survival of out-of-hospital cardiac arrest.

Design of 30Watt Inverter for high luminance LCD Backlight Application (LCD용 고휘도 Backlight 구동을 위한 30Watt급 인버터의 설계)

  • 허정욱;김태조;임성규
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.747-750
    • /
    • 1999
  • A 30Watt inverter with 300: 1 dimming capability for high luminance, one cell, surface discharge plasma light source for LCD backlight was designed and tested. It was possible to achieve 300:1 dimming control by using the push-pull type inverter with burst-mode dimming control. The surface discharge plasma light cell with luminance of more than 5, 260 cd/$m^2$ was successfully operated.

  • PDF

A Study on Frequency Control and Active Power Control of Wind Turbine Generation System for PMSG (PMSG 풍력발전 시스템의 출력 제어 및 주파수 제어 연구)

  • Lee, Kwang-Soo;Kim, Mun-Kyeom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.597-607
    • /
    • 2014
  • This paper proposes active power control and frequency support control schemes of wind turbine generation system by using modified Maximum Power Point Tracking(MPPT) of Permanent Magnet Synchronous Generator(PMSG). Most wind turbine generation system is completely decoupled from the power system and power output control with pitch control. According to the frequency deviation, however, MPPT control can not contribute to the frequency change of the power system due to its active power output control. For solving this, the de-loaded(DL) control scheme is constructed for the frequency support control, which is based on applying the active power output control in the rotor speed control of PMSG. The rotor speed by used in the proposed DL control scheme is increased more than the optimal rotor speed of MPPT, and then this speed improvement increases the saved kinetic energy(KE). In order to show the effectiveness of the proposed control scheme, the case studies have been performed using the PSCAD/EMTDC. The results show that the proposed active power output control scheme(DL control and KE discharge control) works properly and the frequency response ability of the power system can be also improved with the frequency support of wind farm.

Evaluation of an Individualized Education before Discharge and Follow-up Telephone Consultation on Self-efficacy for Kidney Transplant Patients (신장이식환자의 자기효능전략을 이용한 퇴원 시 개별교육과 추후 전화상담의 효과)

  • Hwang, Young-hui;Yi, Myungsun
    • Journal of Korean Biological Nursing Science
    • /
    • v.17 no.4
    • /
    • pp.331-340
    • /
    • 2015
  • Purpose: This study was to develop and evaluate an individualized education program based on self-efficacy for patients with kidney transplantation in Korea. Methods: A nonequivalent control group pretest-posttest design was used. The participants consisted of 43 patients who underwent kidney transplants at one hospital in Seoul, from July 2012 to April 2013. The experimental group received an individualized education based on self-efficacy in the hospital and follow-up telephone consultation in the 2nd and 3rd week after discharge. The control group received a routine discharge education. Knowledge, self-efficacy, and compliance related to kidney transplant were measured and analyzed by frequency, average, Mann-Whitney U test, Fisher's exact test, independent t-test, and ${\chi}^2$-test using SPSS WIN 20.0. Results: Significant differences were found in self-efficacy between the experimental group and the control group. But no significant differences were found in knowledge and compliance between two groups. The scores of several items on monitoring health status in compliance were higher in the experimental group than those of the control group. Conclusion: The results of this study demonstrate the fact that an education program based in self-efficacy for patients with kidney transplant would be effective in improving self-efficacy and the ability to monitor their health status.

Effects of the Nurse-led Discharge Education on Symptom Experience and Self-Care Compliance in Patients with Chronic Obstructive Pulmonary Disease (일대일 퇴원교육이 만성폐쇄성 폐질환자의 증상경험 및 자가간호수행에 미치는 효과)

  • Cho, Eun-Hye;Hwang, Seon-Young
    • Korean Journal of Adult Nursing
    • /
    • v.23 no.6
    • /
    • pp.595-604
    • /
    • 2011
  • Purpose: This study was conducted to examine the effects of the nurse-led one-on-one discharge education on the levels of symptom experience and self-care compliance among patients with chronic obstructive pulmonary disease (COPD) who had not previously participated in an education or respiratory rehabilitation program. Methods: This study used a quasi-experimental pre-and post-test design with nonequivalent control group. Sixty seven hospitalized patients (34 for experimental and 33 for control groups) were recruited from in-patient units of a general hospital from August to November, 2010. The one-on-one education session of symptom management and daily self-care was administered to experimental group for 50 minutes along with a follow-up phone call. Self-administered questionnaire was administered at the pretest and at 1 month after discharge. Results: The subjects were 67.43(${\pm}10.24$)years old in average. The mean differences of symptom experience (t=3.39, p=.001) and self-care compliance (t=-38.13, p<.001) in the experimental group was significantly higher than those of the control group. Conclusion: Nurse-led one-on-one discharge education was effective in reducing the level of symptom experience and enhancing self-care compliance at home within one month after discharge. Therefore, this form of one-on-one education provided by nurses might be applicable effectively for COPD patients who do not have access to respiratory rehabilitation programs.

PREDICTION OF THE ORIFICE DISCHARGE COEFFICIENT USING COMPUTATIONAL FLUIDS DYNAMICS (전산유동해석을 이용한 ORIFICE 방출 계수 예측)

  • Ok, H.;Kim, I.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.147-150
    • /
    • 2006
  • Vent ports are installed on the walls of closed compartments of a launch vehicle to control the pressure drop in the compartments. The ports can be modelled as an orifice, and the accurate prediction of the discharge coefficient of an orifice is essential for the design of vent ports. Experimental methods have been used to determine the discharge coefficients for various shapes of orifices, and extensive databases are available. Wind tunnel tests have been also done to evaluate the effect of interaction between venting outflow and freestream for limited conditions. The goal of the present research is to predict the discharge coefficient of an orifice using CFD and evaluate the accuracy of the method, especially for the orifices exposed to the external flow.

  • PDF

Discharge Characteristics of a KSTAR NBI Ion Source

  • Chang Doo-Hee;Oh Byung-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.226-233
    • /
    • 2003
  • The discharge characteristics of a prototype ion source was investigated, which was developed and upgraded for the NBI (Neutral Beam Injection) heating system of KSTAR (Korea Superconducting Tokamak Advanced Research). The ion source was designed for the arc discharge of magnetic bucket chamber with multi-pole cusp fields. The ion source was discharged by the emission-limited mode with the control of filament heating voltage. The maximum ion density was 4 times larger than the previous discharge controlled by a space-charge-limited mode with fully heated filament. The plasma (ion) density and arc current were proportional to the filament voltage, but the discharge efficiency was inversely proportional to the operating pressure of hydrogen gas. The maximum ion density and arc current were obtained with constant arc voltage ($80{\sim}100V$), as $8{\times}10^{11}cm^{-3}$ and 1200 A, respectively. The estimated maximum beam current was about 35 A, extracted by the accelerating voltage of 80kV.

Optimal cell structure of a wall-cathode and wall auxiliary anode for high performance plasma display panel (벽형의 음극 전극과 보조 전극을 갖는 고효율 플라즈마 표시기의 최적 전극 구조에 관한연구)

  • 신범제;정희섭;서정현;황기웅
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.6
    • /
    • pp.33-42
    • /
    • 1997
  • In this paper, a new structure for a dC plasma display pane(PDP) with a wall-catode and a wall-auxilizry anode has been suggested. The wall-cathode with a sufficient discharge area maximizes the discharge volume. The auxiliary anode surrounding the discharge region makes the effective control of the charged particles possible. We have investigated the cahracteristics of the new cell structure with a 2-dimensional computer simulation and a micro gap discharge system, and compared experimentally with those of previous cell structure. The new cell structure with the wall-cathode and auxiliary wall-anode turned out to have improved luminance, discharge forming time and sustain voltage.

  • PDF

Development and Evaluation of a Transitional Care Program for Patients Discharged from Military Hospitals (군병원 퇴원환자의 전환관리 프로그램 개발 및 효과 평가)

  • Joe, Seun-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.4
    • /
    • pp.599-609
    • /
    • 2010
  • Purpose: The purpose of this study was to develop and evaluate a transitional care program for patients discharged from military hospitals. The study consists of two phases: developing the program and evaluating its effectiveness. Methods: The conceptual framework used to guide the development of the program was Meleis's transition theory. A quasiexperimental design was employed for this study. Participants were recruited from patients discharged from one military hospital, 72 in the control group and 56 in the experiment group. Data were analyzed using SPSS WIN 12.0 program with chi-square, Fisher's exact test, independent t-test, and mixed model. Results: Participants in the transitional care program reported promoting a positive personal condition, and more healthy patterns of response in the first week after being discharged and a smoother discharge transition. Conclusion: The transitional care program developed for discharge patients from military hospital promoted discharge readiness and promoted smooth discharge transition.

A Study on Color Control in Gas Discharge Tube with the Variation of Frequency (주파수 변화에 따라 기체 방전관 색상 제어에 관한 연구)

  • Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.53-56
    • /
    • 1996
  • In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of Hg-Ne (10 Torr), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency high voltage. As increasing frequency in the gas discharge tube, the phenomena, that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing frequency. The method of changing frequency has been shown to be suitable for the luminous color control.

  • PDF