• Title/Summary/Keyword: Discharge Control

Search Result 1,428, Processing Time 0.03 seconds

Case Control Study Identifying the Predictors of Unplanned Intensive Care Unit Readmission After Discharge (집중치료실 퇴실환자의 비계획성 재입실 예측 인자를 규명하기 위한 사례대조군 연구)

  • Park, Myoung Ok;Oh, Hyun Soo
    • Journal of Korean Critical Care Nursing
    • /
    • v.11 no.3
    • /
    • pp.45-57
    • /
    • 2018
  • Purpose : This study was performed to identify the influencing factors of unplanned intensive care unit (ICU) readmission. Methods : The study adopted a Rretrospective case control cohort design. Data were collected from the electronic medical records of 844 patients who had been discharged from the ICUs of a university hospital in Incheon from June 2014 to December 2014. Results : The study found the unplanned ICU readmission rate was to be 6.4%(n=54). From the univariate analysis revealed that, major symptoms at $1^{st}$ ICU admission, severity at $1^{st}$ ICU admission (CPSCS and APACHE II), duration of applying ventilator application during $1^{st}$ ICU admission, severity at $1^{st}$ discharge from ICU (CPSCS, APACHE II, and GCS), and application of $FiO_2$ with oxygen therapy, implementation of sputum expectoration methods, and length of stay of ICU at $1^{st}$ ICU discharge were appeared to be significant; further, decision tree model analysis revealed that while only 4 variables (sputum expectoration methods, length of stay of ICU, $FiO_2$ with oxygen therapy at $1^{st}$ ICU discharge, and major symptoms at $1^{st}$ ICU admission) were shown to be significant. Conclusions : Since sputum expectoration method was the most important factor to predictor of unplanned ICU readmission, a assessment tool for the patients' capability of sputum expectoration needs to should be developed and implemented, and standardized ICU discharge criteria, including the factors identified from the by empirical evidences, might should be developed to decrease the unplanned ICU readmission rate.

A Study on the Wear Behavior of Tetrahedral Amorphous Carbon Coatings Based on Bending Angles of the Filtered Cathodic Vacuum Arc with Different Arc Discharge Currents (자장여과아크소스의 자장필터 꺾임 각도와 아크방전전류에 따라 증착된 ta-C 코팅의 마모 거동 연구)

  • Kim, Won-Seok;Kim, Songkil;Jang, Young-Jun;Kim, Jongkuk
    • Tribology and Lubricants
    • /
    • v.38 no.3
    • /
    • pp.101-108
    • /
    • 2022
  • The structure and properties of tetrahedral amorphous carbon (ta-C) coatings depend on the main process parameters and bending angles of the magnetic field filter used in the filtered cathodic vacuum arc (FCVA). During the process, it is possible to effectively control the plasma flux of carbon ions incident on the substrate by controlling the arc discharge current, thereby influencing the mechanical properties of the coating film. Furthermore, we can control the size and amount of large particles mixed during carbon film formation while conforming with the bending angle of the mechanical filter mounted on the FCVA; therefore, it also influences the mechanical properties. In this study, we consider tribological characteristics for filtered bending angles of 45° and 90° as a function of arc discharge currents of 60 and 100 A, respectively. Experiment results indicate that the frictional behavior of the ta-C coating film is independent of the bending angle of the filter. However, its sliding wear behavior significantly changes according to the bending angle of the FCVA filter, unlike the effect of the discharge current. Further, upon changing the bending angle from 45° to 90°, abrasive wear gets accelerated, thereby changing the size and mixing amount of macro particles inside the coating film.

A Control Method of Bidirectional DC-DC Converter for Fuel Utilization and Durability Improvement in Fuel Cell Vehicles (연료전지자동차에서 연료이용률과 연료전지 내구성 향상을 위한 양방향 DC-DC 컨버터의 제어기법)

  • Jo, Jin-Sang;Jung, Sang-Min;Lee, Jin-Hee;Han, Soo-Bin;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.428-435
    • /
    • 2005
  • In this paper a power controller is proposed to accurately control the commanded power for charge and discharge operation of a bidirectional DC-DC converter so that durability is improved in hybrid systems such as fuel cell vehicles. Also, a control algorithm for charge and discharge operation is proposed to improve fuel utilization and keep battery SOC constant so that energy is effectively utilized.

Cascaded H-bridge Multilevel Inverter for High Precision and Linear Control of the Rate of Ozone Yielding

  • Park, Sung-Jun;Kang, Feel-Soon
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.321-329
    • /
    • 2013
  • A multilevel inverter employing a cascade transformer is proposed for a silent-discharge-tube ozone generating system. The proposed inverter consists of four full-bridge inverters and fourteen transformers which have a series-connected secondary. It can accurately control the amplitude of the output voltage; hereby, it improves a linear characteristic of the rate of ozone yielding. The power regulation characteristics and operational principle of the proposed system are explained from a practical point of view. High precision ozone generating performance of the proposed multilevel inverter is verified by computer-aided simulations and experiment results.

Battery Discharge System Configuration using Photovoltaic Simulator and PCS (태양광 시뮬레이터와 PCS를 이용한 배터리 방전시스템 구성)

  • Jeong, Da-Woom;Park, Sung-Min;Park, Seong-Mi;Park, Sung-Jun;Moon, Seung-Pil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.491-498
    • /
    • 2020
  • Recently, In the production line of batteries, charge and discharge tests are essential to verify battery characteristics. In this case, the battery charging uses a unidirectional AC/DC converter capable of output voltage and current control, and the discharge uses a resistive load. Since this method consumes energy during discharge, it must be replaced with a bi-directional AC/DC converter system capable of charging and discharging. Although it is difficult to replace the connected inverter part of the bi-directional AC/DC converter system due to the high cost, the spread of the solar-connected inverter rapidly increases as the current solar supply business is activated, and thereby the solar-connected type Inverter prices are plunging. If it can be used as a power converter for battery discharge without program modification of the solar-powered inverter, it will have competition. In this paper, propose a new battery discharge system using a combination of a photovoltaic DC/DC simulator and photovoltaic PCS using a battery to be used as a power converter for battery discharge without program modification of a low-cost photovoltaic inverter. In addition, propose an optimal solar characteristic curve for the stable operation of PCS. The validity of the proposed system was verified using a 500[W] class solar DC/DC simulator and a solar PCS prototype.

Hydraulic Relation of Discharge and Velocity in Small, Steep Mountain Streams Using the Salt-dilution Method (Salt-dilution 방법을 이용한 산지소하천의 유량과 유속 관계 분석)

  • Yang, Hyunje;Lee, Sung-Jae;Im, Sangjun
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.2
    • /
    • pp.158-165
    • /
    • 2018
  • Reach-average velocity prediction in steep mountain streams is important for understanding fluvial processes and practical applications of erosion control in mountain streams. little studies have been conducted in reach-average velocity, but hydraulic researches have been carried out to examine the relationship between discharge and reach-average velocity in torrent reaches using a relatively large amount of discharge data. In this study, a total of 87 data were measured in 8 torrent reaches. Salt-dilution method was used to estimate discharge. Reach-average velocity was calculated from harmonic mean of travel time that were measured by salt-dilution technique. In order to exlpore the hydraulic relation, both discharge and velocity were non-dimensionalized by using $D_{50}$, $D_{84}$, ${\sigma}_{pro}$ and $IPR_{90}$. It also indicated that ${\sigma}_{pro}$ and $IPR_{90}$ were good variables as roughness height for develop the relationship between non-dimensional discharge and velocity in mountain streams. Generally, reach-average velocity could increase exponentially as discharge increases.

Ecological Characteristics of Marine Algal Communities at the Discharge Canals of Three Nuclear Power Plants on the East Coast of Korea (동해안 3개 원전 배수로 해조군집의 생태적 특성)

  • Kim, Young-Hwan;Ahn, Jung-Kwan
    • ALGAE
    • /
    • v.20 no.3
    • /
    • pp.217-224
    • /
    • 2005
  • The species composition and biomass of marine algae at the discharge canals of three (Gori, Wolseong and Uljin) nuclear power plants on the east coast of Korea were investigated seasonally from February 1992 to October 2000. As a result, 103-107 species of marine algae were found at the discharge canals during the past nine years. In general, algal communities established at the discharge canals were less diverse than those at the intake canals and control sites. 43 species (6 blue-green, 9 green, 10 brown and 18 red algae) of marine algae occurred more than 1/6 frequency and thus can be categorized as warm tolerant species. Among these, two green (Urospora penicilliformis, Cladophora albida), four brown (Sphacelaria divaricata, S. rigidula, Sargassum coreanum, S. fulvellum) and four red algae (Stylonema alsidii, Bangia atropurpurea, Hypnea charoides, Chondria crassicaulis) are recorded as warm tolerant marine algae for the first time in Korea during this study. Enteromorpha compressa, Padina arborescens, Amphiroa zonata and Ahnfeltiopsis flabelliformis were common species found more than 50% frequency at the discharge canals of all three nuclear power plants investigated. Dominant species in biomass were Padina arborescens and Amphiroa zonata. Results showed that, as a whole, the red algae appeared as predominant algal group at the discharge canals of all three nuclear power plants on the east coast of Korea. However, the biomass proportion of dominant algae at the discharge canals of each nuclear power plant varied over the year during the past nine years.

Micro-gap DBD Plasma and Its Applications

  • Zhang, Zhitao;Liu, Cheng;Bai, Mindi;Yang, Bo;Mao, Chengqi
    • Journal of the Speleological Society of Korea
    • /
    • no.76
    • /
    • pp.37-42
    • /
    • 2006
  • The Dielectric Barrier Discharge (DBD) is a nonequilibrium gas discharge that is generated in the space between two electrodes, which are separated by an insulating dielectric layer. The dielectric layer can be put on either of the two electrodes or be inserted in the space between two electrodes. If an AC or pulse high voltage is applied to the electrodes that is operated at applied frequency from 50Hz to several MHz and applied voltages from a few to a few tens of kilovolts rms, the breakdown can occur in working gas, resulting in large numbers of micro-discharges across the gap, the gas discharge is the so called DBD. Compared with most other means for nonequilibrium discharges, the main advantage of the DBD is that active species for chemical reaction can be produced at low temperature and atmospheric pressure without the vacuum set up, it also presents many unique physical and chemical process including light, heat, sound and electricity. This has led to a number of important applications such as ozone synthesizing, UV lamp house, CO2 lasers, et al. In recent years, due to its potential applications in plasma chemistry, semiconductor etching, pollution control, nanometer material and large area flat plasma display panels, DBD has received intensive attention from many researchers and is becoming a hot topic in the field of non-thermal plasma.

The development of the discharge reactor for water purification and a spectroscopic study on its discharge emission (수처리용 방전 리액터의 개발과 방전 발광의 분광학적 분석 연구)

  • Han, Sang-Bo;Park, Jae-Youn;Kim, Jong-Seog;Jung, Jang-Gun;Koh, Hee-Seog;Park, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.581-582
    • /
    • 2005
  • In order to apply the discharge plasma processing. to industrial areas, the control of the chemical reaction mechanism is necessary. The hybrid plasma reactor was designed for the effective treatment of wastewater and hazardous volatile organic substances. This plasma reactor was similar to the barrier discharge, and surface discharge on the dielectric surface was propagated to the water surface strongly for the heterogeneous chemical reaction at the interface between the working gas and the water surface. The discharge emission in this discharge reactor was mainly $N_2$ second positive band in the case of $N_2$ or air gas atmosphere, and intensities from OH radicals in Ar gas atmosphere were stronger than in $N_2$ or air gas atmosphere. From this result, it is necessary to apply Ar gas for the effective generation of OH radicals in this plasma reactor.

  • PDF

EFFECTS OF MONOCALCIUM PHOSPHATE SUPPLEMENTATION ON PHOSPHORUS DISCHARGE AND GROWTH OF CARP (Cyprinus carpio) GROWER

  • Kim, J.D.;Ahn, K.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.4
    • /
    • pp.521-526
    • /
    • 1993
  • Two percent of monocalcuim phosphate (MCP) was added to control diet consisted of fish meal (18%), soybean meal (36%) and wheat flour (37%) in order to examine the effects on phosphorus (P) discharge and growth of carp (Cyprinus carpio). Growth trial, during which digestibility measurements were made over 7 days, was conducted for 4 weeks using a recirculated rearing system with a settling column for feces collection. Fishes (initial body weight of about 200 g) were fed five times a day upto satiation with tank controlled at $24-26^{\circ}C$. Fishes fed the diet containing 2% MCP (MCP-2) showed about two-fold improvement on both growth rate and feed utilization, compared to those of fishes fed the control diet; weight gain (129 g vs 62 g), feed conversion ratio (1.20 vs 2.46), protein efficiency ratio (2.09 vs 1.07) and daily growth index (3.70 vs 1.93). However, feed intakes were maintained at the same level (150 g/fish) between the two treatments. Dry matter digestibilities of two diets were relatively low, which were 58 and 60% for respective control and MCP-2 diets due to low digestibility of total carbohydrates. However, the digestibilities of both dietary protein (85%) and lipid (90%) of diets were relatively high. While all the P fed were observed to be discharged from fish fed control diet, the discharge from fish fed the MCP-2 diet was decreased up to less than the half (34.9 g/kg wt. gain) of the control. These present results revealed that the supplementation of dietary P requirement by MCP can not only promote growth performances but also reduce the level of P loading to water which is the primary water pollution indicator.