• 제목/요약/키워드: Discharge Control

검색결과 1,425건 처리시간 0.025초

관외착빙형 빙축열조의 방열성능 모델링 (Modelling of Thermal Discharge Performance for Ice-on-coil Type Ice-Storage Tank)

  • 이상렬;이경호;최병윤;한승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.280-285
    • /
    • 2001
  • This paper presents a modelling of thermal discharge performance for a static ice-on-coil ice-storage tank. Through the present study, discharging characteristics were examined with the existing results of theoretical and numerical heat transfer analyses. Also, an experiment was conducted to obtain a real set of discharge performance. The thermal effectiveness, the ratio of the actual heat transfer rate to the maximum possible heat transfer rate, decreased when the stored energy decreased during discharging period. And the effectiveness increased as the coolant flow rate through the storage increased, of which increasing rate decreased abruptly near the maximum and the minimum stored energy. An empirical correlation was obtained from the experimental and the numerical analysis data.

  • PDF

ESTIMATION OF DAM DISCHARGE FOR THE DOWN STREAM WATER QUALITY

  • Ha, Jin-Kyu;Hong, Il-Pyo
    • 물과 미래
    • /
    • 제35권5호
    • /
    • pp.51-59
    • /
    • 2002
  • In recent years the human impact on the environment becomes increasing lift threatening, calls for the better management of resources. In field of water quality of river flow, the best way to conserve water quality is specific efforts to control the pollutant loadings and treat the loadings in the basin to reduce the discharge of pollutant loadings to river. But in general the water quality influenced by the dam discharge. Especially in dry season, it is more dominant way to improve the water quality which contaminated with the pollutant loadings from the basin. The dam discharge amounts of the 2 dams in the Keum River that maintain the down stream water quality were estimated for the year of 1999, 2001, 2006, 2011, in case of irrigation and non-irrigation seasons. The pollutant loadings for the basin are estimated with the planning of treatment plants construction schedule for every sub-basins. The river flow rates were considered low flow as 2.33 year low flow and 10 year low flow. The QUAL2E model was used as a tool of simulation.

  • PDF

Development of a Microwave Discharge Ion Engine using Multi-Monopole Antenna

  • Nakashima, H.;Miyamoto, T.;Mii, K.;Nishijima, T.;Ijiri, H.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.314-317
    • /
    • 2004
  • On 9/5/2003, the planet probe “HAYABUSA” as MUSES-C project was launched by The Institute of Space and Astronautical Science. “HAYABUSA” has microwave discharge ion engines and these engines are characterized by their high efficiency and specific impulse in comparison with chemical engine. A large ion engine can be used as a planet explorer, while a small ion engine can be used as attitude control of small satellite. We have been developing a high thrust density microwave discharge ion engine using “Multi-Monopole Antenna”. The performance of this engine are: ion cost of 344W/A, propellant utilization efficiency of 52% and thrust density of 0.055mN/$\textrm{cm}^2$ for Kr gas flow rate of 2.5sccm, microwave(2.45㎓) power of 32W and acceleration voltage of l.4㎸.

  • PDF

Analysis of the Effects of SD Plasma on Aerodynamic Drag Reduction of a High-speed Train

  • Lee, Hyung-Woo;Kwon, Hyeok-Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1712-1718
    • /
    • 2014
  • Experimental analysis according to the plasma actuator design variables was performed in order to verify the effects of sliding discharge plasma on aerodynamic drag reduction of a high-speed train. For the study, sliding discharge plasma actuator and high-frequency, high-voltage power supply were developed and experimented to figure out the best design variables for highest ionic wind velocity which could reduce the drag force. And then, 5% reduced-scale model of a high-speed train was built for wind tunnel test to verify it. From the results, it was confirmed that sliding discharge plasma had contribution to reduce the drag force and it had the potential to be applied to real-scale trains.

유동대전에 의한 절연유중의 정전기 방전기구와 대책에 관한 연구 (A Study on the Mechanism and Countermeasure of Electrostatic Discharge in Insulating Oil by Streaming Electrification)

  • 박광현;임헌찬;김두식;황명환;육재호;이덕출
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.10-15
    • /
    • 1993
  • In this paper, it is studied the electrostatic discharge In Insulating oil for the purpose of the technical control of the streaming electrification resulted from the interface between an insulating liquid and a solid. The streaming current increases exponentially with flow rate and In region of lower than 50[$^{\circ}C$]but decreases at higher than the same temperature. The phenomena of electrostatic discharge appear at an interface between measuring tank and insulating oil when the seven sheets of gauzes are inserted in electrification apparatus. And those of partial or surface discharge are shown when eight sheets are inserted.

  • PDF

선대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 바이어스된 3전극의 영향 (Effect of the Biased Third Electrode of a Wire-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.648-652
    • /
    • 2008
  • Corona discharge and ozone generation characteristics of a wire-plate plasma reactor, with a biased third electrode, have been investigated with an emphasis on the role of the bias voltage and frequency applied on the third electrode. It was found that the wire-plate plasma reactor, with the biased third electrode, had a switching characteristic on its I-V characteristics for negative and positive discharges, which is very different from that of a conventional wire-plate plasma reactor without the third electrode. As a result, the corona discharge and ozone generation characteristics of the proposed plasma reactor could be controlled by adjusting the bias voltage and frequency of the third electrode. The corona onset and breakdown voltages, and ozone generation and yield, were increased compared with those of without the third electrode. These, however, reveal the effectiveness of the biased third electrode.

AISI 4340강의 방전가공에서 공정변수의 최적화 (Optimization of Process Parameters for AISI 4340 Steel in Electrical Discharge Machining)

  • 최만성
    • 반도체디스플레이기술학회지
    • /
    • 제18권2호
    • /
    • pp.17-22
    • /
    • 2019
  • The method of electrical discharge machining (EDM), one of the processing methods based on non-traditional manufacturing procedures, is gaining increased popularity, since it does not require cutting tools and allows machining involving hard, brittle, thin and complex geometry. This present investigation details the determination of optimum process parameter to attain the better machining performance in EDM of AISI 4340 steel with graphite as a tool electrode. The experimental combinations are planned and analyzed by Taguchi's design of experiments approach. To predict the optimal condition, the experiments are conducted by using Taguchi's L27 orthogonal array. The influence of process variables such as discharge current, pulse on and pulse off time, voltage and spark speed were investigated to control the various desired performance measures such as surface roughness. Analysis of Variance (ANOVA) has to be performed to know the magnitude of each factor. Investigations indicate that the surface roughness is strongly depend on pulsed current.

신월빗물저류배수시설의 수직유입구 설계조건에 따른 유입특성 분석 연구 (A study on vertical inlet of inflow characteristics of the Shinwol rainwater storage & drainage system by design condition)

  • 박수호;오준오;박재현;박창근
    • 한국수자원학회논문집
    • /
    • 제50권2호
    • /
    • pp.129-138
    • /
    • 2017
  • 대심도 저류 및 배수터널은 기 개발된 도시의 부족한 배수관망 능력을 보강하기 위하여 지하에 설치하는 대규모 도시홍수 배제 시설물로 원활한 홍수 유입을 위해 적정한 규모의 수직유입구가 요구되어진다. 접선형 수직유입구 설계 시 유입구의 능력을 평가하는 중요인자로 Yu and Lee(2009)가 지배유량개념을 소개하였는데, 본 연구에서는 서울시에 설치하고자 하는 신월빗물저류배수시설의 수직유입구 3개소를 대상으로 수리모형실험을 실시하고 제안된 지배유량 개념의 적정성을 평가하였다. 지배유량 이론식($Q_{cp}$)을 이용하여 실제 측정된 지배유량($Q_{cm}$)과 비교 분석하였는데, 그 결과 이론식 대비 66~69%로 이론식이 지배유량을 과대 산정하는 것으로 평가되었다. 지배유량 이론식의 과대산정 원인을 분석하기 위하여 Yu and Lee (2009)가 사용한 자료들과 본 연구에서 측정된 자료들을 활용하여 지배유량비($Q_{cm}/Q_{cp}$)를 3가지 영역으로 분류하고 각 인자에 대한 민감도 분석을 실시하였다. Yu and Lee (2009)가 제안한 지배유량식은 접선형 수직유입구 설계인자인 B, z, ${\beta}$, e/B에 대한 영향만 고려하였으나 ${\theta}$, L과 연계된 변수들로 복합적으로 고려하는 식의 개선이 필요한 것으로 판단된다.

원자력발전소 직류전원계통용 축전지 성능시험 분석 (Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant)

  • 김대식;차한주
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

입원 기간 중 관상동맥 우회술 환자를 위한 심장재활 교육의 효과 (Effect of Cardiac Rehabilitation Education for Coronary Artery Bypass Grafting Patients during Their Hospitalization)

  • 최명애;김금순;이명선;최스미;이정숙
    • Journal of Korean Biological Nursing Science
    • /
    • 제10권1호
    • /
    • pp.69-79
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of cardiac rehabilitation education for CABG patients on anxiety & depression, self-esteem, general health status, health related quality of life, body mass index, serum lipid concentration (high density lipoprotein, low density lipoprotein, total cholesterol), heart rate and blood pressure. The subjects of the study consisted of 36 patients who underwent CABG at A hospital in Seoul, from January 1, 2006 to June 30, 2007. The experimental group (20 patients) received the individual education during the hospitalization. The control group (16 patients) received routine discharge education by ward nurses. Psychological variables, general health status and health related quality of life (QOL) after cardiac rehabilitation education were determined by self-reported questionnaire at 1st week, 3rd week and 6th week after the discharge. Physiological variables were measured in out patient visiting at 4th week after discharge. Score of anxiety & depression and health related QOL in the experimental group showed a significant decrease at 1st week, 3rd week and 6th week after the discharge compared with the control group. Score of self-esteem, general health status and physiological variables in the experimental group showed no significant difference from the control group.

  • PDF