• Title/Summary/Keyword: Discharge Control

Search Result 1,425, Processing Time 0.025 seconds

Effects of Tailored Supportive Education on Physical, Emotional Status and Quality of Life in Patients with Congestive Heart Failure (맞춤형 지지교육이 심부전증 환자의 신체, 정서적 상태 및 삶의 질에 미치는 효과)

  • Lee, Eun-Sook;Shin, Eun-Suk;Hwang, Seon-Young;Chae, Myeong Jeong;Jeong, Myoung-Ho
    • Korean Journal of Adult Nursing
    • /
    • v.25 no.1
    • /
    • pp.62-73
    • /
    • 2013
  • Purpose: This study was conducted to examine the effects of tailored supportive education on physical, psychological status and quality of life in the patients with congestive heart failure (CHF) who had not participated previously in cardiac rehabilitation program. Methods: This study was used a non-equivalent control pre-post design, conducted on 64 CHF patients under medical treatment in a hospital. The experimental group (n=31) received the tailored supportive educational program (once 1~2 days before discharge and 6 times after discharge through outpatient visits or telephone contact: once every week for the first 4 weeks after discharge and once every 2 weeks for the remaining 4 weeks). The control group (n=33) received a traditional discharge education. Data were analyzed using descriptive statistics, ${\chi}^2$-test, Fisher's exact test, t-test and repeated measure ANOVA using the SPSS/ WIN 18.0 program. Results: Participants in the experimental group showed the significantly increased scores of the quality of life (F=16.01, p<.001), and the significantly decreased scores of physical function (F=7.27, p=.009), depression (F=8.25, p=.006) and anxiety (F=4.11, p=.047), when compared to those of the control group. Conclusion: The findings indicated tailored supportive education was an effective intervention care in physical, emotional status and quality of life for CHF patients.

The PV MPPT & Charge and Discharge Algorithm for the Battery Included Solar Cell Applications (배터리 내장형 초소형 태양광 장치용 PV MPPT 및 충방전 제어 알고리즘)

  • Kim, Seung-Min;Park, Bong-Hee;Choi, Ju-Yeop;Choy, Ick;Lee, Sang-Chul;Lae, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.69-75
    • /
    • 2013
  • To increase the efficiency of the photovoltaic, almost photovoltaic appliances are controlled by Maximum Power Point Tracking(MPPT). Existing most of the PV MPPT techniques have used power which multiplies sensed output current and voltage of the solar cell. However, these algorithms are unnecessarily complicated and too expensive for small and compact system. The other hand, the proposed MPPT technique is only one sensing of the MPPT converter's output current, so there is no need to insert another sensors of battery side. Therefore, this algorithm is simpler compared to the traditional approach and is suitable for low power solar system. Further, the novel proper charge/discharge algorithm for the battery with PV MPPT is developed. In this algorithm, there is CC battery charge mode and load discharge mode of the PV cell & battery dual. Also we design current control to regulate allowable current during the battery charging. The proposed algorithm will be applicable to battery included solar cell applications like solar lantern and solar remote control car. Finally, the proposed method has been verified with computer simulation.

A Case-control Study of unexpected Readmission in a University Hospital (비예정 재입원의 위험요인에 대한 환자-대조군 연구)

  • Yu, Seung-Hum;Oh, Hyohn-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.3
    • /
    • pp.289-296
    • /
    • 1999
  • Objectives: This study describes the risk factors affecting the unexpected readmission of 261 patients who were discharged from a university hospital in Seoul. Methods: This case-control study reviewed medical records of inpatients who had been discharged from a hospital between 1 August 1995 and 31 October 1995 after the treatment for general diseases. The cases were 68 patients who were readmitted unexpectedly within 28 days of discharge from an index stay, and the controls were 193 Patients who were discharged without readmission during the study period. Results: Logistic regression analysis results were as follows; Patients who had no operation during their hospital stay were more likely to be readmitted unexpectedly than patients who had operation. Patients who had 1 or 2 parts of their body being involved in treatment were more likely to be readmitted unexpectedly than patients who hand more than 3 parts of their body being involved in treatment. Patients who had complications after surgery were more likely to be readmitted unexpectedly than patients who had no complications. Insufficient discharge planning caused unexpected readmissions. Conclusions: Discharge planning education should be extended to health care providers. And the assessment of discharge planning should be evaluated. Readmission is often necessary for the treatment of related problems of originating from initial hospitalization, which causes cost problems. Unexpected readmission is preventable and the models for readmission can serve as a valuable clinical tool for high risk patients.

  • PDF

High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method (제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식)

  • Jung, Jae-Chul;Seo, In-Woo;Oh, Byung-Joo;Whang, Ki-Woong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

The Effects of Individualized Education on Stroke Patients' Post-discharge Anxiety and Self-care Compliance (개별화된 교육이 허혈성 뇌졸중 환자의 불안과 자가간호수행에 미치는 효과)

  • Park, Hyoung-Sook;Lee, Mee-Hun;Ha, Jae-Hyun
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: This study aimed to identify the effect of individualized education on stroke patients' post-discharge anxiety and self-care compliance. Methods: It was a pretest-posttest design with non-equivalent groups. A total of 32 hospitalized stroke patients in experimental group were given individualized education three times at one day before, the day of and one week after discharge. Data were analyzed using descriptive statistics, t-test and $x^2$-test. Results: The scores of anxiety at posttest were $45.66{\pm}9.58$ in control group and $35.44{\pm}8.21$ in the experimental group. Self-compliance scores were $44.00{\pm}7.99$ in control and $61.06{\pm}7.69$ in the experimental group. These indicate that anxiety score is significantly lower (t=-4.58, p<.001), and self-compliance score is significantly higher (t=8.70, p<.001) in experimental group. Conclusion: If stroke patients receive a relevant individualized education, it could help reduce their anxiety. Also it would be useful to maintain and improve their self-care compliance after discharge.

A Study on Color Control in Gas Discharge Tube (기체 방전관의색상 제어에 관한 연구)

  • Lee, Jong-Chan;Aono, Masaharu;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.285-288
    • /
    • 1996
  • The electronic operation of the gas discharge tube is controlled by the electrical energy as sinusoidal waveform in arbitrary frequency range, or as a sequence of pulses at a wide range of duty cycle, the gas composition, the kind of electrode and the vessel geometry. In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of IIg-Ne ( 10 Torr ), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency and pulse width in high voltage. As increasing pulse width and frequency in the gas discharge tube, the phenomenons that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist. The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing pulse width and frequency. The changing method of pulse width and frequency has been shown to be suitable for the luminous color control.

  • PDF

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

Soft-Start Open Circuit Voltage and Constant Current Sequence Control of 2.5[kW] HID Search Lamp for Ship (선박용 2.5[kW] HID 탐사등의 Soft-Start 방식에 의한 개방회로 전압과 점등전류 순차 제어)

  • Park, Noh-Sik;Kwon, Soon-Jae;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.45-51
    • /
    • 2008
  • HID(High Intensity Discharge) search lamp for shipment requires a high open circuit and output current compare than vehicle. This paper presents a soft-start open circuit voltage and constant current sequence control method for 2.5[kW] HID search lamp. The proposed method controls the opal circuit voltage and discharge current of HID lamp according to ignition signal with a simple 8-bit micro-processor and PWM device. For the stable control of lamp, micro-processor checks the output voltage and current. And the checked signals are compared with ignition signal and changes the control mode for stable operation. An ignition signal and micro-processor change the control mode from open circuit voltage contort to constant current control. The proposed control scheme is verified from experimental tests of 2.5[kW] HID search lamp for shipment.

Evaluation of Channel-forming Discharge for the Abandoned Channel Restoration Design of Cheongmi Stream (청미천 구하도 복원 설계를 위한 하도형성유량 산정)

  • Ji, Un;Kang, Jun-Gu;Yeo, Woon-Kwang;Han, Seung-Won
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.12
    • /
    • pp.1113-1124
    • /
    • 2009
  • The abandoned channel restoration is one of methods to enhance the environmental function and ecological habitat as well as the functions of water-utilization and flood control. The channel-forming or dominant discharge must be evaluated and defined to design the cross-sectional and plane geometries of the stable and equilibrium channel for the abandoned channel restoration project. In general, bankfull discharge, specified recurrence interval discharge, and effective discharge have been used to decide the channel-forming discharge. In this study, bankfull discharge, specified recurrence interval discharge, and effective discharge were calculated and compared for the abandoned channel restoration site of Cheongmi Stream and their relations to historical bed changes were analyzed. The bankfull discharge, 488 $m^3/s$, of the abandoned channel restoration site of Cheongmi Stream was calculated using HEC-RAS data and ranged between 1.5-year and 2-year recurrence discharges. Also, the effective discharge evaluated with the sediment rating curve and mean daily discharge data is greater than the bankfull discharge. According to the survey data of 1994 and 2008, the bed elevation of the study reach was decreased over time. It is indicated that the channel bed is changing to the stable condition to allow the effective discharge.

The induced discharge characteristics in atmosphere adopting a pulsed $CO_2$ laser (펄스형 $CO_2$ 레이저를 이용한 기중 침 대 침 전극간의 유도방전 특성)

  • Jung, Yong-Ho;Choi, Jin-Young;Lee, Yu-Soo;Chung, Hyun-Ju;Song, Gun-Ju;Kim, Hee-Je
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.172-175
    • /
    • 2002
  • The technique of induced discharge by a pulsed CO2 laser is being applied to control electrical discharge path, material processing, triggered lightning for protecting the power equipments. In this paper, we have investigated about the characteristics of the induced discharge at atmospheric conditions by using a plasma channel, which is produced when a pulsed CO2 laser radiation is focused by a focusing mirror as a trigger source. A plasma channel produced by laser radiation has an effect on decreasing the threshold voltage and inducing the discharge in both needle electrodes. We have confirmed a delay time between a produced plasma channel and an electrical discharge after laser radiation. We provided the decreased voltage lower than the natural discharge voltage between electrode type of needles and was induced the discharge by forming a plasma channel between them. In this research we could understand the time delay of induced discharge by laser radiation, and the characteristics of the discharge cause by the decrease in the threshold voltage, and the polarity effect by changes of plasma channel positions between two electrodes.

  • PDF