• 제목/요약/키워드: Disc displacement

검색결과 197건 처리시간 0.026초

Buckling delamination of the PZT/Metal/PZT sandwich circular plate-disc with penny-shaped interface cracks

  • Cafarova, Fazile I.;Akbarov, Surkay D.;Yahnioglu, Nazmiye
    • Smart Structures and Systems
    • /
    • 제19권2호
    • /
    • pp.163-179
    • /
    • 2017
  • The axisymmetric buckling delamination of the Piezoelectric/Metal/Piezoelectric (PZT/Metal/PZT) sandwich circular plate with interface penny-shaped cracks is investigated. The case is considered where open-circuit conditions with respect to the electrical displacement on the upper and lower surfaces, and short-circuit conditions with respect to the electrical potential on the lateral surface of the face layers are satisfied. It is assumed that the edge surfaces of the cracks have an infinitesimal rotationally symmetric initial imperfection and the development of this imperfection with rotationally symmetric compressive forces acting on the lateral surface of the plate is studied by employing the exact geometrically non-linear field equations and relations of electro-elasticity for piezoelectric materials. The sought values are presented in the power series form with respect to the small parameter which characterizes the degree of the initial imperfection. The zeroth and first approximations are used for investigation of stability loss and buckling delamination problems. It is established that the equations and relations related to the first approximation coincide with the corresponding ones of the three-dimensional linearized theory of stability of electro-elasticity for piezoelectric materials. The quantities related to the zeroth approximation are determined analytically, however the quantities related to the first approximation are determined numerically by employing Finite Element Method (FEM). Numerical results on the critical radial stresses acting in the layers of the plate are presented and discussed. In particular, it is established that the piezoelectricity of the face layer material causes an increase (a decrease) in the values of the critical compressive stress acting in the face (core) layer.

Radiologic Evaluation of Proper Pedicle Screw Placement after Pedicle Screw Fixation in Degenerative Lumbar Disc Disease

  • Ju, Sun-Min;Kim, Young-Soo;Kim, Sung-Bum;Ko, Yong;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권4호
    • /
    • pp.265-268
    • /
    • 2005
  • Objective : With the increasing popularity of pedicle screw fixation devices for several indications, the safety and reliability of screw insertion in the small pedicle has become a major issue. Many studies have investigated the accuracy of screw placement after pedicle screw fixation using various method. The reported displacement rates have been very different. The purpose of the study is to investigate the proper placement of pedicle screw insertion in the lumbar spine on 26 consecutive patients. Methods : Between September and December 2003, 26 consecutive patients [16women and 10men] were analyzed after transpedicular screw fixation of the lumbar and lumbosacral spine. After pedicle screw fixation in this study, 2-mm slices of CT scan were performed in all patients to detect caudal and cranial deviation of screw and medial and lateral deviation. Pedcile screw placement related complication was evaluated clinically. Results : A total of 144 inserted pedicle were analyzed in 26patients, and 58pedicle screws [40.3%] were detected to be improper placement. There were 14level [9.0%] of caudal or cranial deviation and 44level [30.6%] of medial or lateral deviation to the pedicle. Extra-pedicle placement was found on 4levels [2.7%] with only lease of neurologic injury. Conclusion : Proper screw placement, though complication rate is low, is important not only for clinical symptom but also for biomechanics. Further study for screw placement related biomechanical changes is needed.

Effect of simultaneous therapy of arthrocentesis and occlusal splints on temporomandibular disorders: anterior disc displacement without reduction

  • Lee, Hye-Sung;Baek, Hyun-Su;Song, Dong-Suk;Kim, Hee-Chul;Kim, Hyo-Geun;Kim, Bok-Joo;Kim, Myung-Soo;Shin, Sang-Hoon;Jung, Sung-Hee;Kim, Chul-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권1호
    • /
    • pp.14-20
    • /
    • 2013
  • Objectives: This study sought to evaluate the effect of simultaneous application of arthrocentesis and occlusal splint. Materials and Methods: A retrospective study of 43 patients (3 males, 40 females) whose symptoms had improved was conducted at the Department of Oral and Maxillofacial Surgery, Dong-A University Hospital between 2008 and 2010. Subjects were divided into three groups: Group A (17 patients with arthrocentesis and occlusal splints simultaneously applied), Group B (13 patients whose symptoms did not improve with occlusal splints, undergoing arthrocentesis after occlusal splint use for 8 weeks), and Group C (13 patients that only used occlusal splints). We compared these groups in maximum comfortable opening (MCO) and the visual analogue scale of pain and noise. Follow-up was performed at 1 week, 1 month, 3 months, and 6 months. Results: The improvement of symptoms was noted in all three groups, but Group A had a quicker improvement than the other groups, in terms of pain reduction and MCO increases. Conclusion: The simultaneous application of arthrocentesis and occlusal splints can reduce patient discomfort more quickly.

임상증상에 따른 악관절이상의 방사선학적 소견에 대한 비교연구 (RADIOLOGICAL EVALUATION OF TEMPOROMANDIBULAR JOINT DISORDERS FOLLOWED BY CLINICAL SYMPTOMS)

  • 박태원;유동수
    • 치과방사선
    • /
    • 제19권1호
    • /
    • pp.7-18
    • /
    • 1989
  • The authors analyzed the clinical findings, radiological findings and their correlations in the temporomandibular joint disorders. The results were as follows: 1. The most prevalent age group was in the first decade, then the second decade and the third decade. Female were more common with a ratio of 3.4:1. 2. The most common clinical findings was the pain on open mouth position (42.3%), then came the clicking and limitation of mouth opening. 3. The most common bone change on the condyle side was the erosion, then came the flattening, the osteopyte and the sclerosis in that orders. 4. In the case of the crepitus, the coarse crepitus showed more radiological change than the fine crepitus. The 27% of the patients with crepitus showed the bone change and the patients with crepitus showed more bone change than any other clinical symptoms. 5. In the case of the mouth opening limitation, the evaluation of the translatory movement by transcranial projection was in accordance with the clinical evaluation. 6. The correlation between the clinical symptom and the condylar position within the mandibular fossa was not present and in the case of diagnosis of disc displacement, the transcranial projection seemed not to be able to substitute for the arthrography. Radiographically, the most prevalent age group which showed the bone change was in the first, the second and the third decade. And the bone change seemed to have no relationship with aging.

  • PDF

Lateral pterygoid muscle volume and migraine in patients with temporomandibular disorders

  • Lopes, Sergio Lucio Pereira De Castro;Costa, Andre Luiz Ferreira;Gamba, Thiago De Oliveira;Flores, Isadora Luana;Cruz, Adriana Dibo;Min, Li Li
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.1-5
    • /
    • 2015
  • Purpose: Lateral pterygoid muscle (LPM) plays an important role in jaw movement and has been implicated in Temporomandibular disorders (TMDs). Migraine has been described as a common symptom in patients with TMDs and may be related to muscle hyperactivity. This study aimed to compare LPM volume in individuals with and without migraine, using segmentation of the LPM in magnetic resonance (MR) imaging of the TMJ. Materials and Methods: Twenty patients with migraine and 20 volunteers without migraine underwent a clinical examination of the TMJ, according to the Research Diagnostic Criteria for TMDs. MR imaging was performed and the LPM was segmented using the ITK-SNAP 1.4.1 software, which calculates the volume of each segmented structure in voxels per cubic millimeter. The chi-squared test and the Fisher's exact test were used to relate the TMD variables obtained from the MR images and clinical examinations to the presence of migraine. Logistic binary regression was used to determine the importance of each factor for predicting the presence of a migraine headache. Results: Patients with TMDs and migraine tended to have hypertrophy of the LPM (58.7%). In addition, abnormal mandibular movements (61.2%) and disc displacement (70.0%) were found to be the most common signs in patients with TMDs and migraine. Conclusion: In patients with TMDs and simultaneous migraine, the LPM tends to be hypertrophic. LPM segmentation on MR imaging may be an alternative method to study this muscle in such patients because the hypertrophic LPM is not always palpable.

헤드각이 변화하는 Electrosurgical Knee Wand에 적용된 형상기억합금 스프링의 전기적 피로특성 (Electro-fatigue Characteristic of Shape Memory Alloy Applied to the Electrosurgical Knee Wand of Variation of Wand Head Angle in Electrosurgical Knee Surgeries)

  • 안재욱;김철웅;이호상;왕준호;오동준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1547-1552
    • /
    • 2008
  • The tip of these catheter with straight needles is not able to reach in the vicinity of the disc bulging, which are the cause of the low back pain and because the far indirect radio-frequency treatment results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body catheter device. To increase the possibility of nucleoplasty, the needle tip should be located at the closest area of the lesion. For this reason, the best way to increase the success rate of the operation is that the needle tip should access 3-dimensionally to the operating field as soon as possible. To achieve this aim, our studies are restricted as follows: 1) the SMA catheter design to control the 3-dimensional direction, 2) the security of the immediate response by the positive control of the SMA element thermal distribution using Peltier thermoelectric elements, 3) the aquisition of the control data by monitoring the relationship between the temperature of SMA element and the displacement, and 4) the design of the controller to guarantee the accurate location.

  • PDF

Clinical evaluation of temporomandibular joint disorder after orthognathic surgery in skeletal class II malocclusion patients

  • Jang, Jin-Hyun;Choi, Sung-Keun;Park, Sung-Ho;Kim, Jin-Woo;Kim, Sun-Jong;Kim, Myung-Rae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제38권3호
    • /
    • pp.139-144
    • /
    • 2012
  • This study was performed in order to evaluate the occurrence of temporomandibular joint disorder after surgical correction of skeletal class II malocclusion. Materials and Methods: This study included 21 patients who underwent orthognathic surgery for the correction of dentofacial deformities by a single surgeon at Mokdong Hospital, Ewha Womans University from 2000 to 2010. They underwent bilateral sagittal split ramus osteotomy for the treatment of undesirable mandibular advancement. The temporomandibular disorder (TMD) symptoms prior to surgery were recorded and the radiographic evaluation (panorama, bone scan, and magnetic resonance imaging [MRI]) of the post-surgery temporomandibular joint (TMJ) were assessed in order to evaluate condylar resorption, remodeling and disc displacement. The minimum follow-up period, including orthodontic treatment, was 12 months. Orthognathic procedures included 1-jaw surgery (n=8 patients) and 2-jaw surgery (n=13 patients). The monocortical plate was used for bilateral sagittal split ramus osteotomy fixation. Results: Among class II malocclusion patients with TMD symptom, clicking improved in 29.1%, and maximum mouth opening increased from $34.5{\pm}2.1$ mm to $37.2{\pm}3.5$ mm. The differences were not statistically significant, however. Radiographic changes in bone scan improved slightly based on the report by radiologist but not in TMJ dynamic MRI. Conclusion: No particular improvements were found in patients with joint sound only. Patients with limitation of mouth opening showed an increase in the degree of opening, but the difference was not statistically significant (P>0.05).

Cam의 CAD/CAM (CAD/CAM system for Cam)

  • 김기대
    • Journal of Biosystems Engineering
    • /
    • 제16권3호
    • /
    • pp.228-238
    • /
    • 1991
  • Cam plays very important roles due to continuous requirement for the high-speed and automation of the machinery. A large number of studies of cam curve were carried out by many researchers, and CNC milling and machining center for manufacturing cam have been widely used recently. The purpose of this study was to develop a CAD/CAM system for cam using QuickBasic language in 16-bit PC for application of cam design and manufacturing. Results obtained were as follows : 1. It was possible to input data by entering cam angle and its corresponding R, from 0 to 360 deg. of cam angle. The tediousness at entering data was minimized because of the same data format for both cylindrical cam and disc cam, and free format used for data file. 2. It was possible to design cam by choosing only the number of cam curve because of developing the CAD/CAM program with dimensionless method of cam curves including widely used 19 kinds. After selecting the number of the cam curve, the CAD/CAM system automatically shows the characteristics of cam motion enough to help a designer to decide : displacement, velocity, acceleration and jerk. 3. It was possible to execute, in an efficient way, both the cam profile synthesis and the generation of NC program for CNC machining center by using the input data. 4. This NC program generated by the CAD/CAM system developed here, was evaluated as positive in relation with actual manufacturing experiments and thought to be useful in its application without any modification. It can be said that this CAD/CAM system could be used by the beginners to design and manufacture the cam automatically as the system consists of very simple dialogue methods. In addition, self-developed QuickBasic would be would used as a basic tool for further stuides in this area of research, together with application.

  • PDF

MRI를 이용한 한국인 하악과두의 형태에 관한 연구 (A STUDY ON THE MORPHOLOGY OF MANDIBULAR CONDYLE)

  • 이두희;오순호;서창호;김준배
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권5호
    • /
    • pp.423-427
    • /
    • 2001
  • Objective: This study was prepared to figure out a certain dimension and morphology of the condyle at the central, medial and lateral aspects on MR images of asymptomatic volunteers, which could be comparable with those of the TMD patients' condyle. Materials: Sixty TMJs from 30 asymptomatic volunteers(15 male, 15 female) who had no clinical symptoms and no disc displacement on sagital and coronal view of MRI were served as normal. Method: MR images were taken from the asymptomatic volunteers and the dimension of the anteroposterior length, mediolateral width, height, convexities were measured through the images on the sagittal and coronal sections of mandibular condyle. Then, these data were collected and analyzed. Result: The mean value of anteroposterior length was $8.00{\pm}1.21mm$ at central section and mediolateral length was $21.40{\pm}2.32mm$ on coronal view. The anterior condylar length at medial side was the shortest and the convexity of anterior slop at the lateral side was proved to be the flattest among 3 sections. There were little dimensional and morphological differences at sagittal sections, but the mediolateral width of condyle at coronal section was significantly different between male and female. Conclusion: In sagittal sections, the anterior condyle length was shortest at medial side and the convexity of anterior slop was flattest at lateral side, and there were little dimensional and morphologic differences between male and female. In coronal section, male's condyle was more wider and flatter than female's.

  • PDF

Evaluation of TMJ sound on the subject with TMJ disorder by Joint Vibration Analysis

  • Hwang, In-Taek;Jung, Da-Un;Lee, Jae-Hoon;Kang, Dong-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.26-30
    • /
    • 2009
  • STATEMENT OF PROBLEM. Qualitative and semi-quantitative methods have been developed for TMJ sound classification, but the criteria presented are completely inhomogeneous. Thus, to develop more objective criteria for defining TMJ sounds, electroacoustical systems have been developed. We used Joint vibration analysis in the BioPAK system(Bioresearch Inc., Milwaukee, USA) as the electrovibratography. PURPOSE. The aim of this study was to examine the TMJ sounds with repect to frequency spectra patterns and the integral > 300 Hz /< 300 Hz ratios via six-months follow-up. MATERIAL AND METHODS. This study was done before and after the six-months recordings with 20 dental school students showed anterior disk displacement with reduction. Joint vibrations were analyzed using a mathematical technique known as the Fast Fourier Transform. RESULTS. In this study Group I and Group II showed varied integral > 300 /< 300 ratios before and after the six-months recordings. Also, by the comparative study between the integral > 300 /< 300 ratios and the frequency spectrums, it was conceivable that the frequency spectrums showed similar patterns at the same location that the joint sound occurred before and after the six-months recordings. while the frequency spectrums showed varied patterns at the different locations that the joint sound occurred before and after six-month recordings, it would possibly be due to the differences in the degree of internal derangement and/or in the shape of the disc. CONCLUSIONS. It is suggested that clinicians consider the integral > 300 /< 300 ratios as well as the frequency spectrums to decide the starting-point of the treatment for TMJ sounds.