• Title/Summary/Keyword: Disc Height

Search Result 145, Processing Time 0.117 seconds

Analysis of Spinal Stability Affected by Working Height, Safety Handrail and Work Experience in Using Movable Scaffold (이동식 틀비계 사용 작업 시 작업대 높이, 안전난간 유무, 숙련도에 따른 척추 안정성 분석)

  • Kim, Jung-Yong;Min, Seung-Nam;Sung, Si-Hoon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.3
    • /
    • pp.347-356
    • /
    • 2010
  • The purpose of this study is to analyze the spine stability by comparing muscle activation in various scaffold working conditions. The independent working conditions were designed by two levels of working height, existence and absence of safety handrail, and the two levels of expertise. The corresponding activities of the agonist and antagonist muscles of spine were simultaneously recorded by using EMG. As results, novice worker showed increased muscle activity while doing the task on the 2nd floor, absence of handrail. And expert showed the increase of co-contraction while working on the 2nd floor without handrail. Such co-contraction was found to increase the spine stability when the working condition become risky. On the other hand, the co-contraction was prolonged, the spine muscle fatique and disc pressure could be increased, which would increase the risk of musculo-skeletal disorder. The results of co-contraction in this study indicates that the motor control system responds to maintain the stability of the spine particularly when workers cognitively recognize the danger of falling or imbalance. This study also quantitatively accounted for the biomechanical cause of LBP among workers who has to prevent themselves from falling. Therefore, if can be said that safe environment preventing falling can also prevent workers from MSDs as well. Such knowledge can be applied to design ergonomic workplace environment as well as movable scaffold.

Efficacy of Unilateral Biportal Endoscopic Decompression in Lumbar Foraminal Stenosis (요추 추간공 협착증에서 일측성 양방향 내시경적 측부 추간공 감압술의 효과)

  • Lee, Ji-Min;Woo, Young-Ha;Yoo, Seong-Ho;Kim, Young-Jun;Seo, Jin-Hyuk;Bae, Hyuk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.5
    • /
    • pp.411-417
    • /
    • 2020
  • Purpose: This paper reports the short-term clinical and radiological results of unilateral biportal endoscopic decompression (UBE) to prove its efficacy. Materials and Methods: Twenty patients who received unilateral biportal endoscopic far-lateral decompression (UBEFLD) were analyzed statistically using the visual analogue scale (VAS), modified Macnab criteria and Oswestry Disability Index (ODI) clinically. Radiologically, their intervertebral angle (IVA), percentage slip, disc height index (DHI) and foraminal height index (FHI) were analyzed pre- and postoperatively. Results: The VAS scores were 6.20 preoperatively, which improved to 2.05, 1.75 and 1.45 at postoperative one month, three months and one year, respectively (p<0.001). The modified macnab criteria in both the good or excellent category was 70.0%, 80.0% and 85.0% at postoperative one month, three months and one year, respectively (p=0.034). The ODI improved from 59.8% preoperatively to 35.8%, 33.2%, and 17.1% at postoperative one month, three months, and one year, respectively (p<0.001). The IVA was increased 0.40±0.88 after a surgery (p=0.057). Percentage slip was increased 0.19% after surgery (p=0.134). The DHI changed from 0.49 preoperatively to 0.62 postoperatively (p=0.359), and the FHI changed from 0.71 preoperatively to 0.79 postoperatively (p<0.001). Conclusion: UBEFLD displayed satisfactory results. Such a result highlights the potential of UBEFLD as an excellent alternative to spinal fusion or microscopic surgery.

Thermopile Radiometer Calibration Using Reference Instrument (표준준기에 의한 일사계 교정)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.199.2-199.2
    • /
    • 2010
  • The main purpose of the calibration procedure is to perform a one to one comparison of the reference pyranometer and the test pyranometer. In order to achieve this, both pyranometers need to be exposed to exactly the same irradiance, under the same circumstances. There are a number of error sources that could result in a wrong measurement. Most importantly Lamp instability, pyranometer offsets, thermal offsets of junctions, voltmeter offset, voltmeter instability, reference pyranometer instability, tilting of the pyranometers and differences in sensor height. Another sun-disc calibration procedure compares the computed vertical component of the direct irradiance as measured by a pyranometer with that measured by the pyranometer to be calibrated. Readings are taken with the levelled pyranometer on a clear day. Firstly the global irradiance and then the diffuse component are measured. Simultaneously measurement of direct irradiance is made with the pyrheliometer. The ways of performing the calibration and the subsequent calculation have been chosen such that the effect all these error sources has been eliminated as much as possible.

  • PDF

A Study on Major Health Components of National Health Examination Survey in Korea (국민건강진단조사(National Health Examination Survey) 내용선정에 관한 연구)

  • Lee, Soon-Young;Kim, Hae-Kyung;Park, Ju-Won;Shin, Seung-Soo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.2 s.61
    • /
    • pp.167-182
    • /
    • 1998
  • The purpose of this study was to identify the major health components and measurements to be conducted in National Health Examination Survey(KNHES). The prevalence and severity of disease, acceptability of population and the possibility of standardization of measurement were considered as guideline for selecting the components. On the base of magnitude and severity of disease, chronic liver disease, hepatic cancer, gastric ulcer, stomach cancer, essential hypertension, cerebrovascular disease, ischemic heart disease, pulmonary tuberculosis, lung cancer, DM, breast cancer, cervical cancer, arthritis and intervertebral disc disorder were selected as the preliminary target diseases. Questionnaire survey for 648 persons in 'K' city and medical specialists in five clinical societies were conducted for evaluation the acceptability of general population for the measurements and the possibility of standardization for the procedures. In conclusion, the major target diseases were chronic liver disease, hypertension and DM and the total cholesterol, high density lipoprotein, triglyceride, total protein, albumin, hemoglobulin, hematocrit, platlet count, anti-HBs, HBsAg, height and weight were selected for basic physical components.

  • PDF

A Study on the Pressure Resonance with Combustion Chamber Geometry for a Spark Ignition Engine (스파크 점화기관의 연소실 형상에 따른 공진현상 해석에 관한 연구)

  • Park, Gyeong-Seok;Jang, Seok-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1905-1910
    • /
    • 2001
  • Pressure resonance frequency that is caused in the combustion chamber can be interpreted by acoustic analysis. Until now the pressure resonance has been assumed and calculated to a disc type combustion chamber that neglected the combustion chamber height because the knock occurs near the TDC(top dead center). In this research FEM(finite element method) has been used to calculate the pressure resonance frequency inside the experimental engine combustion. The error of the resonance frequency obtained by FEM has decreased about 50% compared to the calculation of Draper's equation. Due to the asymmetry in the shape of the combustion chamber that was neglected in Draper's equation we could find out that a new resonance frequency could be generated. To match the experimental results, the speed of sound that satisfies Draper's equation is selected 13% higher than the value for pent-roof type combustion chamber.

The Effects of Spinal Stabilization Exercise using Gravity on patients with Degenerative Disc Disease (중력을 이용한 요부안정화 운동이 만성요통을 가진 노인환자에게 미치는 영향)

  • Kim, Hee-Ra;Kim, Yoon-Shin
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.23-31
    • /
    • 2008
  • Purpose: The purpose of this study was finding out the effects of spinal stabilization exercise using Centaur which is a 3D spinal stabilization sports implement on Chronic low back pain patients over 8 weeks. Methods: 30 patients with DDD were observed during the study. Their average age was 66.88years, height was 152.12cm and average weight was 58.91kg, 4 males and 26 females were involved. 8 various investigations were performed and varied values were compared with reinvestigation done after having exercised 8 weeks using 3-D CENTAUR We used VAS(visual analog scale) in order to see the variation of pain intensity, MOI(modified oswestry index) in order to see limitation of daily life. Results: VAS was lessened from 7.57 to 2.63, limitation of routine life(MOS) from 23.48 to 11.30, there were remarkable differences statistically(p<0.05). As a result of muscular investigation for static spinal stabilization by 8 variations of body deflection, muscular strength were all increased and there were signigicant differences statistically(p<0.05). Conclusion: It has turned out that pain and limitation of routine life was lessened, as a result of 8 weeks exercise using CENTAUR, and deep muscular power was increased. Thus it has turned out that 3-D spinal stabilization exercise has an effect on the strengthening spinal muscles and alleviation of their pain for old patients with DDD.

  • PDF

The Relationship between Anterior Disc Displacement without Reduction and Development of Anterior Open Bite (비정복성 관절원판변위와 전치부 개교합 발생간의 관계)

  • Hur, Yun-Kyung;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.293-303
    • /
    • 2007
  • The purpose of this paper is to evaluate if there is a relationship between anterior disc displacement without reduction and development of anterior open bite, and a relation between occurrence of open bite and occlusal appliance therapy. In general, the statistically significant differences were found between the Group 1 and 2 and normal mean group. The variables that represent mandibular size and form, showed a statistical significance in all 3 groups. Also 3 groups patients had a smaller ANB, a larger FMA than normal mean group. When we compared the 3 groups with respect to all cephalometric measurements by One-way analysis of variance (ANOVA), group 1 and 2 patients had a larger FMA, a larger SN to mandibular plane angle, a larger maxillomandibular plane angle, a larger occlusal plane to mandibular plane angle, a smaller total posterior facial height/total anterior facial height(%), and a larger gonial angle than group 3. The statistically significant differences were not found between the Group 1 and 2, and skeletal patterns were similar. Thus, morphologic features of patients with vertical discrepancies may represent a risk factor for the development of anterior open bite with or without occlusal appliance treatment. In case of patients with vertical discrepancy, we may have to be more careful when inducing a change of the vertical dimension.

Clinical Assessment, Panoramic and MRI Findings and Cephalometric Characteristics of Patients with Condylar Resorption (과두흡수환자의 자기공명영상 사진 평가 및 악안면 골격형태에 대한 연구)

  • Jang, Heon-Su;Hur, Yun-Kyung;Kim, Kyun-Yo;Ko, Yu-Jeong;Chae, Jong-Moon;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.4
    • /
    • pp.409-420
    • /
    • 2009
  • The aim of this study was to investigate clinical assessment, panorama & MRI findings and cephalometric characteristics in 42 patients with condylar resorption, who visited in the Department of Oral Medicine Kyungpook National University Hospital at 2006. The results were as follows; 1. Clinical assessment 1) Female was 34 and male was 8, females were predominant. Distribution of age showed as follows; 10s was 14, 20s was 13, 30s was 7, 40s was 3, 50s was 4 and 60s was 1 patient. 10s and 20s were predominant. 2) Most of the patients had parafunctional habit. 2. Findings of panorama & MRI 1) Most of the patients had degree of Grade II condylar resorption by panorama taking. 2) Most of the patients had disc dislocation and belonged to the degree of stage IV by MRI taking. 3. Cephalometric Characteristics 1) SN, SAr and saddle angle in female patients were significantly smaller and SN in male patients showed only significantly smaller than normal group. 2) SNA showed no difference from the normal group in both patients. SNB was smaller and ANB was lager in female patients than normal group. 3) SN-GoMe and FMA increased in patients. 4) Total posterior facial height & ramus height were significantly smaller. 5) Mandibular body length did not show any significant difference.

A New Standard Gerbera Cultivar 'Paspin' with Pastel Pink and Semi-double for Cut Flower (대륜계통의 파스텔톤 분홍색 반겹꽃 절화용 거베라 신품종 'Paspin')

  • Park, Sang Kun;Lim, Jin Hee;Choi, Seong Youl;Shin, Hak Ki;Lee, Jung Soo
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.4
    • /
    • pp.255-258
    • /
    • 2011
  • A new gerbera cultivar 'Paspin' was released by the National Institute of Horticultural & Herbal Science (NIHHS) in 2009. A cross was made between 'Lilabella' and 'Mephisto' with purple and semi-double in 2005. After investigation of the characteristics for five years (from 2005 to 2009), it was selected specially as a cut flower. The 'Paspin' cultivar has a pastel pink flower color (RHS R52B) with green disc center and semi-double flower. It has large-sized flowers which average flower diameter is about 12.8 cm. And inner ray floret and disc diameters are 7.87 cm and 2.57 cm, respectively. It has an adequate peduncle height of 48.6 cm, and a longer vase life of 10.8 days. It is vigorous in growth and also adaptable to the local cultural environments of Korea. It is expected that if the 'Paspin' cultivar will be planted, the royalty fees to be paid to other countries can be saved. And the local growers will also be benefitted since the cost of cultivars will be lower than the imported ones.

Cervical Cord Decompression Using Extended Anterior Cervical Foraminotomy Technique

  • Kim, Sung-Duk;Ha, Ho-Gyun;Lee, Cheol-Young;Kim, Hyun-Woo;Jung, Chul-Ku;Kim, Jong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.114-120
    • /
    • 2014
  • Objective : At present, gold-standard technique of cervical cord decompression is surgical decompression and fusion. But, many complications related cervical fusion have been reported. We adopted an extended anterior cervical foraminotomy (EACF) technique to decompress the anterolateral portion of cervical cord and report clinical results and effectiveness of this procedure. Methods : Fifty-three patients were operated consecutively using EACF from 2008 to 2013. All of them were operated by a single surgeon via the unilateral approach. Twenty-two patients who exhibited radicular and/or myelopathic symptoms were enrolled in this study. All of them showed cervical cord compression in their preoperative magnetic resonance scan images. Results : In surgical outcomes, 14 patients (64%) were classified as excellent and six (27%), as good. The mean difference of cervical cord anterior-posterior diameter after surgery was 0.92 mm (p<0.01) and transverse area was $9.77mm^2$ (p<0.01). The dynamic radiological study showed that the average post-operative translation (retrolisthesis) was 0.36 mm and the disc height loss at the operated level was 0.81 mm. The change in the Cobb angle decreased to 3.46, and showed slight kyphosis. The average vertebral body resection rate was 11.47%. No procedure-related complications occurred. Only one patient who had two-level decompression needed anterior fusion at one level as a secondary surgery due to postoperative instability. Conclusions : Cervical cord decompression was successfully performed using EACF technique. This procedure will be an alternative surgical option for treating cord compressing lesions. Long-term follow-up and a further study in larger series will be needed.