• Title/Summary/Keyword: Disaster and Safety Management

Search Result 1,222, Processing Time 0.025 seconds

Preliminary Uncertainty Analysis to Build a Data-Driven Prediction Model for Water Quality in Paldang Dam (팔당댐 유역의 데이터 기반 수질 예측 모형 구성을 위한 사전 불확실성 분석)

  • Lee, Eun Jeong;Keum, Ho Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.1
    • /
    • pp.24-35
    • /
    • 2022
  • For water quality management, it is necessary to continuously improve the forecasting by analyzing the past water quality, and a Data-driven model is emerging as an alternative. Because the Data-driven model is built based on a wide range of data, it is essential to apply the correlation analysis method for the combination of input variables to obtain more reliable results. In this study, the Gamma Test was applied as a preceding step to build a faster and more accurate data-driven water quality prediction model. First, a physical-based model (HSPF, EFDC) was operated to produce daily water quality reflecting the complexity of the watershed according to various hydrological conditions for Paldang Dam. The Gamma Test was performed on the water quality at the water quality prediction site (Paldangdam2) and major rivers flowing into the Paldang Dam, and the method of selecting the optimal input data combination was presented through the analysis results (Gamma, Gradient, Standar Error, V-Ratio). As a result of the study, the selection criteria for a more efficient combination of input data that can save time by omitting trial and error when building a data-driven model are presented.

Experimental Study on Ignition and Explosion Hazard by Measuring the Amount of Non-volatile (NVR) and Explosion Limit of Biodiesel Mixture (바이오디젤 혼합물의 가열잔분측정과 폭발한계 측정을 통한 발화 및 폭발위험성에 대한 실험적인 연구)

  • Kim, Ju Suk;Koh, Jae-Sun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.182-193
    • /
    • 2022
  • Purpose: By measuring and evaluating the risk of biodiesel through non-volatile residue (NVR) and flash point and explosion limit measurement at a specific temperature according to ASTM test standards, the risk of chemical fire causative substances is identified and a universal evaluation method By derivation and securing the risk-related data of the material, it can be used for the identification and analysis of the cause of the fire, and it can be applied to the risk assessment of other chemical substances Method: In order to measure the risk of biodiesel, it was measured using the non-volatile residue(NVR) measurement method, which measures how much flammable liquid is generated at a specific temperature. Heating was tested by applying KS M 5000: 2009 Test Method 4111. In addition, the flash point was measured using the method specified in ASTM E659-782005, and the energy supply method was measured using the constant temperature method. In addition, the explosion limit measurement was conducted in accordance with ASTM E 681-04 「Standard test method for concentration limits of flammability of chemicals(Vapors and gases)」 test standard. Result: As a result of checking the amount of combustible liquid by the non-volatile residue (NVR)measurement method, the non-volatile residue(NVR) of general diesel when left at 105±2℃ for 3 hours was about 30% (70% of volatile matter) and about 4% of biodiesel. In addition, similar results were obtained for the non-volatile residue(NVR)heating temperature of 150±2℃, 3 hours and 200±2℃ for 1 hour, and white smoke was generated at 200℃ or higher. In addition, similar values were obtained as a result of experimentally checking the explosion (combustion) limits of general diesel, general diesel containing 20% biodiesel, and 100% biodiesel. Therefore, it was confirmed that the flammability risk did not significantly affect the explosion risk. Conclusion: The results of this study suggested the risk judgment criteria for mixtures through experimental research on flammable mixtures for the purpose of securing the effectiveness, reliability, and reproducibility of the details of the criteria for determining dangerous substances in the existing Dangerous Materials Safety Management Act. It will be possible to provide reference data for the judgment criteria for flammable liquids that are regulated in the field. In addition, if the know-how for each test method is accumulated through this study, it is expected that it will be used as basic data in the research on risk assessment of dangerous substances and as a basis for research on the determination of dangerous substances.

Accuracy Analysis for Slope Movement Characterization by comparing the Data from Real-time Measurement Device and 3D Model Value with Drone based Photogrammetry (도로비탈면 상시계측 실측치와 드론 사진측량에 의한 3D 모델값의 정확도 비교분석)

  • CHO, Han-Kwang;CHANG, Ki-Tae;HONG, Seong-Jin;HONG, Goo-Pyo;KIM, Sang-Hwan;KWON, Se-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.234-252
    • /
    • 2020
  • This paper is to verify the effectiveness of 'Hybrid Disaster Management Strategy' that integrates 'RTM(Real-time Monitoring) based On-line' and 'UAV based Off-line' system. For landslide prone area where sensors were installed, the conventional way of risk management so far has entirely relied on RTM data collected from the field through the instrumentation devices. But it's not enough due to the limitation of'Pin-point sensor'which tend to provide with only the localized information where sensors have stayed fixed. It lacks, therefore, the whole picture to be grasped. In this paper, utilizing 'Digital Photogrammetry Software Pix4D', the possibility of inference for the deformation of ungauged area has been reviewed. For this purpose, actual measurement data from RTM were compared with the estimated value from 3D point cloud outcome by UAV, and the consequent results has shown very accurate in terms of RMSE.

A History of Termite Control and Improvements to Prevent Termites in Wooden Architectural Heritage (국내외 흰개미 방제 기술의 발달 과정과 목조건축문화재의 흰개미 피해 저감을 위한 방안)

  • LEE, Sangbin;IM, Ikgyun;KIM, Sihyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.2
    • /
    • pp.194-215
    • /
    • 2021
  • Termites are important decomposers in the ecosystem. They are also economically significant structural pests. In this study, we reviewed the developments of termite control and recent research on termite management to provide information on the prevention and control of termites. In Korea, most of the damage to wooden historical buildings is caused by subterranean termites. Reticulitermes speratus kyushuensis is the main species, which is widely found throughout the country. In the early 1900s, inorganic insecticides, such as arsenic dust, were used for termite control. After the synthesis of chlorinated hydrocarbon pesticide in the 1940s, it was widely utilized and demonstrated high termite control efficacy. However, chlorinated hydrocarbon insecticides were later banned, disappearing from markets after reports emerged concerning environmental contamination and toxicity to humans. Therefore, the termite control industry sought a new termiticide; hence many pesticides were utilized for termite control. Organophosphate (1960s), carbamate (1970s), pyrethroid, and insect growth inhibitor (1980s) were newly synthesized and adopted. In the 1990s, the first commercial baits using chitin synthesis inhibitors (CSI) were developed, providing a means to eliminate an entire colony of subterranean termites around a structure. Many studies have been carried out on soil termiticides (liquid termiticides) and CSI baits to increase their efficacy, and different baits such as aboveground bait stations, fluid bait, and high-durability bait were also developed in the 2000s. In addition, the paradigm of termite control has shifted from localized treatments using soil termiticides to area-wide pest management using CSI baits to create termite-free zones and protect buildings over time. Termite infestations in wooden historical buildings in Korea have been reported since 1980, and considerable attention was drawn in the 1990s when several UNESCO world heritages such as the Jongmyo Shrine and the Janggyeong Panjeon Depositories of Haeinsa Temple were infested by subterranean termites. Since then, a survey of termite infestation in wooden architectural heritage has been conducted, and the National Research Institute of Cultural Heritage and Heritage Care Program regularly monitors those properties. Finally, we suggest termite management using primarily CSI baits, selective application of various soil treatments applied to the object, foundation soil treatment, research and development of durable termite baits, application of area-wide programs for wooden-building complexes, application of integrated termite management (ITM), and regular education for owners and managers to prevent and reduce termite damage.

Learning from the USA's Single Emergency Number 911: Policy Implications for Korea (미국 긴급번호 911 운영시스템에 관한 연구: 긴급번호 실질적 통합을 위한 정책 시사점 제시 중심으로)

  • Kim, Hak-Kyong;Lee, Sung-Yong
    • Korean Security Journal
    • /
    • no.43
    • /
    • pp.67-97
    • /
    • 2015
  • In Korea, a single emergency number, such as 911 of the USA and 999 of the UK, does not exist. This issue became highly controversial, when the Sewol Ferry Sinking disaster occurred last year. So, the Korean government has planned to adopt a single emergency number, integrating 112 of the Police, 119 of the Fire and Ambulance, 122 of the Korean Coast Guard, and many other emergency numbers. However, the integration plan recently proposed by the Ministry of Public Safety Security seems to be, what is called, a "partial integration model" which repeals the 122 number, but still maintains 112, 119, and 110 respectively. In this context, the study looks into USA's (diverse) 911 operating system, and subsequently tries to draw general features or characteristics. Further, the research attempts to derive policy implication from the general features. If the proposed partial integration model reflects the policy implications, the model can virtually operate like the 911 system -i.e. a single emergency number system - creating inter-operability between responding agencies such as police, fire, and ambulance, even though it is not a perfect integration model. The features drawn are (1) integration of emergency call-taking, (2) functional separation of call-taking and dispatching, (3) integration of physical facilities for call-taking and dispatching, and (4) professional call-takers and dispatchers. Moreover, the policy implications derived from the characteristics are (1) a user-friendly system - fast but accurate responses, (2) integrated responses to accidents, (3) professional call-taking and dispatching & objective and comprehensive risk assessment, and finally (4) active organizational learning in emergency call centers. Considering the policy implications, the following suggestions need to be applied to the current proposed plan: 1. Emergency services' systems should be tightly linked and connected in a systemic way so that they can communicate and exchange intelligence with one another. 2. Public safety answering points (call centers) of each emergency service should share their education and training modules, manuals, etc. Common training and manuals are also needed for inter-operability. 3. Personal management to enable-long term service in public safety answering points (call centers) should be established as one of the ways to promote professionalism.

  • PDF

A Study on the Appropriate Management of Maritime Police Authority in Korea Coast Guard: Focusing on the Japan Coast Guard (해양경비안전본부의 해양경찰권 적정 운영방안에 관한 연구: -일본 해상보안청과의 비교를 중심으로-)

  • Son, Yeong-Tae
    • Korean Security Journal
    • /
    • no.42
    • /
    • pp.361-391
    • /
    • 2015
  • Regarding the [Government Organization Act; which is legislated on 19th November, 2014] Korea Coast Guard(KCG) has been re-organized and belong from Korea Coast Guard shall be established under the Minister of Oceans and Fisheries to Ministry of Public Safety and Security. Furthermore, National Police Agency(NPA) Commissioner has the right for administer duties concerning investigation and information by succession from Korea Coast Guard Commissioner. That means that main rule has been moved from prior KCG to Ministry of Public Safety and Security(MPSS) and NPA currently which is dual structure. Meanwhile, This kind of organization change has been effective to investigative agency which exert KCG's call of duty and causes needs of variety problems. In other words, There are quite huge changes such as KCG's reduction of their work, call of duty and re-organization regarding revised government organization act. However this change - including re-organization by government, was not able to take current MPSS's special features such as organization specialty and legal rights. It means, the current change has not been taken present law system CRIMINAL PROCEDURE LAW and there was no preparation to stable maritime police authority action as well. To sum up, this revised GOVERNMENT ORGANIZATION ACT is supposed to provide total, quick security service by establishing strong disasters and safety control tower. However they only contains few area such as organization revision regarding 'Sewol Ferry Disaster', they was not able to contain the other parts of Society. Therefore, in this article I would like to check the part of re-evaluation of current change made by KCC's organization revision. It is supposed to provide better legal stability by making clear of work area by government agencies who acts maritime police authority.

  • PDF

Monitoring on Biological Distribution Around Historical Wooden Buildings Adjacent to River - With the Case Study of Silleuksa Temple, Yeoju City?- (수계에 인접한 목조건축물의 생물분포 모니터링 연구 - 여주 신륵사를 중심으로 -)

  • Kim, Si Hyun;Lee, Hyun Ju;Lee, Min Young;Jeong, Seon Hye;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.33 no.4
    • /
    • pp.267-274
    • /
    • 2017
  • The Silleuksa temple in Yeoju city is adjacent to the South Han River and often has high humidity and fog days. In addition, its proximity to forests renders it prone to damage by insects and microorganisms. In order to obtain the basic data necessary for the establishment of a cultural property preservation management plan, the biological distribution of the wooden buildings and the termite distribution in the surrounding forests were monitored for three years. The wood-boring bee, an insect known to inflict damage to heritage structures, was confirmed, and the distribution of insects varied annually and seasonally, presumably due to the location characteristics of the site and the climate change during the year. In the forest behind, termite colonies were identified as a whole and their distribution pattern was different every year. As per the results of the microorganism survey, the species distribution and pollution degree were different at the entrance of the building. Therefore, it needs continuous biological distribution and conservation environment monitoring to mitigate the effects of wood-damaging organisms.were different according to the entrance of the building.

Improvement plan and factual survey for weirs, drop structures and bridges in medium scale streams of Kyonggi province (경기도 지방하천에서의 보, 낙차공 및 교량 시설물의 실태 및 개선 방안 제시)

  • Noh, Huiseong;Ahn, Taejin
    • Journal of Wetlands Research
    • /
    • v.22 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • Weirs are to secure amount water of streams and drop structures are to enhance stabilization of stream bed and bridges are to connect isolated region, which are called stream crossing structures. In the stream design criteria, directions for minimum size of structures are suggested to secure stability of stream crossing structures. However the sizes of almost all existing weirs and drop structures are not satisfied with the stream design criteria and only 22 percent of the peirs of bridges are satisfied. To enhance hydraulic stability of existing weirs and drop structures, it is required that the ratio of bed protection to apron should be above 3.3. According to factual survey of structures in the sample streams, it has been shown that the longitudinal slope of rapid works with 1:20 is the most reasonable to design velocity if existing weirs and drop structures are rehabilitated into rapid works. It has been known that violating freeboard and span length of piers should make existing bridges reconstructed or removed. However, comprehensive review including deterioration level of bridges, special regulation for span length, etc. should be considered to determine rehabilitation plan of bridges. In this study, a procedure has been suggested to improve hydraulic stability of weirs, drop structures and piers of bridges. Sound environment of stream and reduction of natural disaster could be achieved by improving stability of cross structures, which could be obtained by governmental budget and active stream management including observance of design criteria.

Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station (소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성)

  • Kim, Soo Jin;Ham, Seunghon;Jeon, Jeong Seok;Kim, Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.140-151
    • /
    • 2019
  • It is to assess the indoor air quality of the chemical hazardous materials exposed to the fire after firefighters returned to the fire scene. The research subject randomly selected four fire stations located in Seoul, Korea. Two fire stations were set up as control groups after the return of the firefighting activities at the actual fire scene, and two other fire stations were set up as control groups to measure the air quality of the room at normal levels regardless of the action. We conducted 24-hour monitoring for all fire accidents that occurred in Seoul Metropolitan using fire safety map computer system. Also, indoor air quality was measured immediately after homecoming if the experiment group was to be dispatched due to an accident of intermediate or larger scale. 11 hazardous substance items such as fine dust, formaldehyde, volatile organic compounds, PAH, VCM, acidity, asbestos, CO2, NO2, O3 were measured according to the process test method. Three of 11 types of harmful substances exceeded domestic and foreign standards, and one of them was found to be close to foreign standards. In particular, total volatile organic compounds, carbon dioxide and sulfuric acids were 2.5 times, 2.2 times and 1.1 times higher than the standard. Also, for formaldehyde and sulfuric acid, it was measured higher in the control group than in the case group. This findings could be used in policies to improve indoor air quality in the fire station of the Seoul Metropolitan Government.

Runoff analysis according to LID facilities in climate change scenario - focusing on Cheonggyecheon basin (기후변화 시나리오에서의 LID 요소기술 적용에 따른 유출량 분석 - 청계천 유역을 대상으로)

  • Yoon, EuiHyeok;Jang, Chang-Lae;Lee, KyungSu
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.583-595
    • /
    • 2020
  • In this study, using the RCP scenario for Hyoja Drainage subbasin of Cheonggyecheon, we analyzed the change with the Historical and Future rainfall calculated from five GCMs models. As a result of analyzing the average rainfall by each GCMs model, the future rainfall increased by 35.30 to 208.65 mm from the historical rainfall. Future rainfall increased 1.73~16.84% than historical rainfall. In addition, the applicability of LID element technologies such as porous pavement, infiltration trench and green roof was analyzed using the SWMM model. And the applied weight and runoff for each LID element technology are analyzed. As a result of the analysis, although there was a difference for each GCMs model, the runoff increased by 2.58 to 28.78%. However, when single porous pavement and Infiltration trench were applied, Future rainfall decreased by 3.48% and 2.74%, 8.04% and 7.16% in INM-CM4 and MRI-CGCM3 models, respectively. Also, when the two types of LID element technologies were combined, the rainfall decreased by 2.74% and 2.89%, 7.16% and 7.31%, respectively. This is less than or similar to the historical rainfall runoff. As a result of applying the LID elemental technology, it was found that applying a green roof area of about 1/3 of the urban area is the most effective to secure the lag time of runoff. Moreover, when applying the LID method to the old downtown area, it is desirable to consider the priority order in the order of economic cost, maintenance, and cityscape.