• Title/Summary/Keyword: Direct-connected Test Facility

Search Result 3, Processing Time 0.016 seconds

Combustion Test for a Supersonic Combustor Using a Direct-Connected Facility (직결형 설비를 이용한 초음속 연소기 연소 시험)

  • Yang, Inyoung;Lee, Kyung-Jae;Lee, Yang-Ji;Lee, Sanghoon;Kim, Hyungmo;Park, Poomin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.1-7
    • /
    • 2018
  • A combustion test for a supersonic combustor was conducted using a direct-connected type supersonic combustor test facility. The facility was verified for the capability of simulating required flow conditions. The test condition was maintained at Mach 2.0, $915^{\circ}C$ and 496 kPa for 15 s. Using gaseous hydrogen as the fuel, the combustor model was also tested for its ignition and flame holding capability at the fuel equivalence ratio of 0.12. Combustion efficiency was 71%, and the supersonic flow regime was obtained at this test condition.

Development of a Direct-Connected Supersonic Combustor Test Facility (직결형 초음속 연소기 시험 설비 개발)

  • Yang, Inyoung;Lee, Kyung-jae;Lee, Yang-ji;Kim, Hyung-Mo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.290-293
    • /
    • 2017
  • A direct-connected, continuous type combustion test facility was developed to test a supersonic combustor model used in scramjet engines. The facility requirements were determined by assuming the flight speed of Mach 5, yielding the combustor inlet flow speed of Mach 2. Also the cross-section of the supersonic combustor under test was assumed as $32mm{\times}70mm$. As a result, the facility was designed to have the flow total pressure of 548 kPaA, total temperature of 1,320 K, and flow rate of 0.776 kg/s. The facility consists of a turbo type air compressor, electric air heater, vitiation air heater and a two dimensional facility nozzle to accelerate the flow to Mach 2. Also, an oxygen supply system was added to compensate the vitiation. The exhaust de-pressurization system is not added. Designed pressure, temperature, and flow rate were verified through the test operation of the facility.

  • PDF

Combustion Performance According to the Cavity Flameholder Location in a Supersonic Combustor (초음속 연소기에서 공동형 보염기 위치에 따른 연소 성능)

  • Yang, Inyoung;Lee, Kyung-jae;Lee, Yang-ji;Lee, Sang-hoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.13-20
    • /
    • 2020
  • The effect of the relative distance between two cavity flame holders on the performance of a supersonic combustor was experimentally investigated. A rectangular cross-sectional combustor model with one cavity flame holder on each of two facing walls was used, with two difference distances between cavities of 135 mm and 220 mm. The fuel equivalence ratio was varied as 0.16 and 0.38. A direct-connected type test facility was used to provide Mach 2 flow condition. The test results revealed that the combustion pressure was higher for the shorter cavity distance case. But fuel equivalence ratio did not have large effect on the combustion pressure. It was concluded that, to get higher combustor pressure, there needs to be further combustor configuration change such as smaller cavity distance or tandem cavity installation.