불평형 전압 발생 시 유효전력 조절을 통한 전압형 HVDC의 DC전압 제어 방안 (Control Scheme Using Active Power Regulation for DC Voltage of VSC HVDC Under Unbalanced Voltage)

  • 박상인;허재선;문원식;김두희;김재철
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.232-239
    • /
    • 2015
  • Faced with unbalanced grid operation mode, the high voltage direct current (HVDC) based on voltage source converter (VSC) can be properly controlled by a dual current control scheme. For the modular multilevel converter (MMC) controlling the AC side current is able to limit the arm current which flows along the IGBT of submodule (SM) to rated current. However the limitation of the arm current results in leaving the control range of active power at MMC confined to below the rated capacity. As a result, limiting the arm current causes the problem that the DC side voltage of the HVDC can not be controlled to the reference value since MMC HVDC adjusts the DC side voltage through the active power. In this paper, we propose the algorithm adjusting the active powers of both MMCs to resolve the problem. The back-to-back MMC HVDC applying the algorithm is modeled by PSCAD/EMTDC to verify the algorithm.

고정자전압제어 전류형 인버터에 의한 유도전동기 구동시스템의 안정도 해석 (Stability Analysis of Induction Motor Driven by Stator Voltage Controlled CSI)

  • Song, Joong-Ho;Yoon, Tae-Woong;Youn, Myung-Joong
    • 대한전기학회논문지
    • /
    • 제41권1호
    • /
    • pp.32-41
    • /
    • 1992
  • This paper presents a comprehensive study on the stability of several control schemes for the induction motor driven by current source inverters. A stator voltage controlled current source inverter drive system without a speed sensor is investigated in order to find appropriate control schemes, which are primarily based on direct or, alternatively, indirect frequency control scheme. It can be seen, especially that an introduction of the indirect frequency control method improves the inherent instability of the current source inverter drive system for the induction motor. The overall control systems with either voltage control loop or current and voltage control loops in addition to each frequency control scheme, are analyzed by utilizing the root locus method and simulated by computer to show the validity of this analysis.

원전에 사용되는 직류전압제어 대전류원의 개발 (Large-Scale Current Source Development in Nuclear Power Plant)

  • 김종호;최규식
    • 한국항행학회논문지
    • /
    • 제28권3호
    • /
    • pp.348-355
    • /
    • 2024
  • 원전해체 시 대용량 처분시스템을 구동하거나 운영 중 제어봉 구동장치 제어시스템과 같은 대규모 측정전류를 요하는 중요설비를 측정 및 테스트하기 위해서는 측정 매체로서 안정적으로 전류를 공급할 수 있는 전류원이 필요하다. 그러나, 흔히 말하는 전원공급기는 전압원으로서 전압만을 내기 때문에 측정부하에 관계없이 일정한 전류를 공급할 수 있는 전류원 역할을 하지 못한다. 전류원은 전압원과 달리 제품을 만들기가 쉽지 않다. 원전 부품의 전류-전압 변환시험과 같은 건전성을 평가하기 위해서는 정상전류치보다 몇십배 훨씬 큰 수십 mA나 암페어 수준의 전류를 인가하여 테스트를 수행해야 하기 때문에 암페어(ampere) 단위의 전류를 공급할 수 있는 전류원이 필수적이다. 따라서 본 개발품에서는 이러한 필요에 의하여 입력이 전압으로 나타나는 전압원을 이용하여 측정대상에 원하는 전류를 일정하게 공급할 수 있는 전압제어으로서 대용량 전류를 공급할 수 있는 직류전압제어 대전류원을 개발하였다. 개발된 제품의의 신뢰성을 확인하기 위하여 원전에서 사용되는 실제의 데이터값을 적용하여 테스트하였으며, 그 결과를 분석하여 선택회로의 정당성을 입증하였다.

A New Approach for Constant DC Link Voltage in a Direct Drive Variable Speed Wind Energy Conversion System

  • Jeevajothi, R.;Devaraj, D.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.529-538
    • /
    • 2015
  • Due to the high efficiency and compact mechanical structure, direct drive variable speed generators are used for power conversion in wind turbines. The wind energy conversion system (WECS) considered in this paper consists of a permanent magnet synchronous generator (PMSG), uncontrolled rectifier, dc-dc boost converter controlled with maximum power point tracking (MPPT) and adaptive hysteresis controlled voltage source inverter (VSI). For high utilization of the converter's power capability and stabilizing voltage and power flow, constant DC-link voltage is essential. Step and search MPPT algorithm which senses the rectified voltage ($V_{DC}$) alone and controls the same is used to effectively maximize the output power. The adaptive hysteresis band current control is characterized by fast dynamic response and constant switching frequency. With MPPT and adaptive hysteresis band current control in VSI, the DC link voltage is maintained constant under variable wind speeds and transient grid currents respectively.

고정자전압제어 전류형 인버터에 의한 유도전동기의 속도제어 (Speed Control of Induction Motor Driven by Stator Voltage-Controlled CSI)

  • 송중호;윤태웅;김광배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.583-586
    • /
    • 1991
  • This paper presents a comprehensive study on the stability of several control schemes for the induction motor driven by current source inverters. A stator voltage-controlled current source inverter drive system without a speed sensor is investigated in order to find appropriate control schemes, which are primarily based on direct or, alternatively, indirect frequency control scheme. The overall control systems with either voltage control loop or current and voltage control loops provided in addition to each frequency control scheme are analyzed by utilizing the root locus method and simulated by computer to illustrate the validity of this analysis.

  • PDF

직통직권 발전기에 의한 직통분권 전동기의 특성해석 (Analysis of D-C Shunt Motor Characteristics, driving D-C Series Generator)

  • 이승원;한송엽
    • 전기의세계
    • /
    • 제16권1호
    • /
    • pp.7-13
    • /
    • 1967
  • There are many kinds of motors operating by rated voltage which is constant. In this paper, the characteristics of separately excited direct current motor is analyzed when its terminal voltage is varied as its load current. As for this source, direct current generator of a series field is used, and it is driven at constant speed by a primemover. The induced voltage of the generator is propotional to its load current but it saturates as its load current is large. The charateristics of motor is studied by analog computer because of the nonlinearity of generator. The results are as follows: (1) The load current and the rotor speed of motor increase as the load of motor increases. But the speed of rotor decreases for the influence of the saturation of the iron of generator field when its load current is large. (2) Decreasing the inertia of motor and increasing the inductance of the armature circuit improve the stability of motor and the region of stable state. (3) By changing the field current of the motor, the speed and the direction of rotor can be controlled in wide range.

  • PDF

위상제어정류기의 직접 디지털 제어 (Direct Digital Control of the Phase-Controlled Rectifier)

  • 송의호;권봉환
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.31-38
    • /
    • 1991
  • A direct digital control technique of a current source using the phase-controlled rectifier is presented. A digital firing technique without sensing the line voltage is proposed. This scheme generates firing pulses directly from error signal between command and output voltage. Thus the phase detection transformers filters and zero-crossing detector are unnecessary. The synchronism is modeled and analized. Also a software synchronization algorithm is presented without a look up table and controls the system in real time with fast dynamic characteristics. Using the single-chip microprocessor 8097BH, the direct digital control is implemented with minimal hardware structure. Using the time-weighted performance index, the optimal discrete IPM control technique is also proposed to control the current of the PCR.

  • PDF

High-Performance Elevator Traction Using Direct Torque Controlled Induction Motor Drive

  • Arafa, Osama Mohamed;Abdallah, Mohamed Elsayed;Aziz, Ghada Ahmed Abdel
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1156-1165
    • /
    • 2018
  • This paper presents a detailed realization of direct torque controlled induction motor drive for elevator applications. The drive is controlled according to the well-known space vector modulated direct control scheme (SVM-DTC). As the elevator drives are usually equipped with speed sensors, flux estimation is carried out using a current model where two stator currents are measured and accurate instantaneous rotor speed measurement is used to overcome the need for measuring stator voltages. Speed profiling for a comfortable elevator ride and other supervisory control activities to provide smooth operation are also explained. The drive performance is examined and controllers' parameters are fine-tuned using MATLAB/SIMULINK. The blocks used for flux and torque estimation and control in the offline simulation are compiled for real-time using dSPACE Microlabox. The performance of the drive has been verified experimentally. The results show good performance under transient and steady state conditions.

고주파 결합 인덕터 직렬 공진형 ZCS-PFM 초퍼 제어 방식을 이용한 새로운 승압형 DC-DC 컨버터 (A Novel Boost DC-DC Converter using High Frequency Coupled Inductor Series Resonant ZCS-PFM Chopper Control Method)

  • 김홍신;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.63-68
    • /
    • 2017
  • This paper proposes a new non-isolated DC conversion circuit topology of the voltage source coupled inductor series resonant high-frequency PFM controlled boost chopper type DC-DC power converter using two in one IGBT power module, which can efficiently operate under a principle of zero current soft switching for wide output regulation voltage setting ranges and wide fluctuation of the input DC side voltage as well as the load variation ranges. Its steady state operating principle and the output voltage regulation characteristics in the open-loop-based output voltage control scheme without PI controller loop are described and evaluated from theoretical and experimented viewpoints. Finally, in this paper the computer-aided simulation steady-state analysis and the experimental results are presented in order to prove the effectiveness and the validity of voltage regulation characteristics of the proposed series resonant zero current soft switching boost chopper type DC-DC power converter circuit using IGBTs which is based on simple pulse frequency modulation strategy more than, 20kHz.

A CMOS Frequency Synthesizer for 5~6 GHz UNII-Band Sub-Harmonic Direct-Conversion Receiver

  • Jeong, Chan-Young;Yoo, Chang-Sik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권3호
    • /
    • pp.153-159
    • /
    • 2009
  • A CMOS frequency synthesizer for $5{\sim}6$ GHz UNII-band sub-harmonic direct-conversion receiver has been developed. For quadrature down-conversion with sub-harmonic mixing, octa-phase local oscillator (LO) signals are generated by an integer-N type phase-locked loop (PLL) frequency synthesizer. The complex timing issue of feedback divider of the PLL with large division ratio is solved by using multimodulus prescaler. Phase noise of the local oscillator signal is improved by employing the ring-type LC-tank oscillator and switching its tail current source. Implemented in a $0.18{\mu}m$ CMOS technology, the phase noise of the LO signal is lower than -80 dBc/Hz and -113 dBc/Hz at 100 kHz and 1MHz offset, respect-tively. The measured reference spur is lower than -70 dBc and the power consumption is 40 m W from a 1.8 V supply voltage.