• Title/Summary/Keyword: Direct transfer

Search Result 934, Processing Time 0.031 seconds

Comparison of Endotracheal Intubation to Transfer - A Study of Simulation Using the SALT - (이송 중 기관내 삽관의 효율성 비교 - SALT를 이용한 시뮬레이션 연구 -)

  • Yun, Seong-Woo;Jung, Jun-Ho;Lee, Hyo-Ju;Choi, Mi-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.300-302
    • /
    • 2022
  • The purpose of this study is to compare the speed, confidence, and ease of endotracheal intubation in a transfer posture by using the SALT(Supraglottic Airway Laryngopharyngeal Tube), and a direct laryngoscope to improve the ability to implement professional airway management. The subject of the study was an experimental study by a randomized crossover design, targeting 28 first-class emergency medical technicians working in J-do fire station, and the SPSS 20.0 version was used for data analysis. The endotracheal intubation by using SALT showed a significant difference in speed compared to endotracheal intubation by using a direct laryngoscope(p<.001), and also showed a significant difference in confidence and ease(p<.001). If it is transfer to endotracheal intubation by direct laryngoscope, or in the case of transfer patients, if SALT is used, safe and rapid intubation will be possible.

  • PDF

Surgical Treatment of Anomalous Connection of Left Coronary Artery to the Pulmonary Artery [ALCAPA] (주관상동맥-폐동맥 이상연결증의 외과적 수술요법)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.228-233
    • /
    • 1993
  • Patients with anomalous connection of the left coronary artery to the pulmonary artery are at risk for myocardial infarction, and early or sudden death. Between 1986 to 1992, a total of 4 of these patients underwent surgical intervention with various operative techniques at our institution. Age at operation ranged from 2 months to 43 years. Three infant patients had congestive heart failure, 2 of them had mitral regurgitaion, and 1 had ST-T change on elctrocardiogram. Operative techniques included direct coronary artery transfer to the aorta[n=2], intrapulmonary tunnel from the aortopulmonary window[n=1], coronary artery bypass using saphenous vein[n=1]. One deaths occured at 2 weeks after direct coronary arterial transfer due to respiratory failure caused by Respiratory Syncitial virus pneumonia. Supravalvar pulmoanry stenosis occured after intrapulmoanry tunnel. We recommend direct aortic implatation of the anomalous coronary artery at the time of diagnosis. Intrapulmonary tunnel from aortopulmonary window or subclavian-coronary anastomosis could be alternatives in whom aortic implantation is not feasible anatomically.

  • PDF

A Finite Element Heat Transfer Analysis with Coupling of Roll and Molten Metal in Direct Rolling Process (직접압연공정에 있어서 롤과 용탕을 연계한 유한요소 열전도해석)

  • 김영도;강충길
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.946-957
    • /
    • 1994
  • In the steel industries, direct rolling process for production of strip from molten metal has been investigated to simplify processes, to minimize energy consumption, and to improve quality of the strip. In this study, two kinds of practicable scale cooling rollers are proposed. And heat transfer analysis of pool region and cooling roller considering flow of molten metal and roll rotation respectively using the finite element method are performed to obtain the proper initial condition and to observe cooling characteristics of cooling roller. From the results, variations of solidification final points and temperature distribution in roller are observed quantitatively according to roll rotation.

The Experimental heat transfer Analysis of a High torque and low speed direct drive rotary motor (고토크 저속 직접 구동식 회전 모터의 열특성 분석)

  • Jung, Moon-Kyung;Lee, Sang-Min;Choi, Moon-Suk;Um, Suk-Kee
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1391-1396
    • /
    • 2009
  • The direct drive motor used in a precision motion rotate at about 1/10 speed and high torque comparing with general rotary motor. Excessive heating of the coils cause an exacerbating the heat problems and reducing the performance of motor. Because the rotation speed of the rotor and surrounding air is low, the motor can not be inefficiently cooled, the thermal analysis in the motor is very important. As the variations of rotation speed and torque, the temperature of several parts is measured and the features of the heat transfer is analyzed and improved.

  • PDF

Direct Numerical Simulation of Mass Transfer in Turbulent Flow Around a Rotating Circular Cylinder (II) - Effect of Schmidt Number - (회전하는 원형단면 실린더 주위의 난류유동 물질전달에 대한)

  • Hwang Jong-Yeon;Yang Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.846-853
    • /
    • 2005
  • In this paper, mass transfer in turbulent flow around a rotating circular cylinder is investigated by Direct Numerical Simulation for Schmidt numbers Sc=1 and 1670. Correlation between Sherwood and Reynolds number predicted agrees well with other experimental results over both Sc. Reynolds analogy identified at Sc=1 definitely causes a strong correlation between concentration fluctuation and streamwise velocity. For Sc=1670, it is found that positive small values of concentration fluctuations are observed more frequently than the case of Sc=1 particularly out of the range of Nernst diffusion layer in the viscous sub-layer. This fact is fully confirmed by detailed statistical study using a probability density function of concentration fluctuations.

Injection Media Affecting Expression of Transgene Introduced by Direct in vivo Injection into Olive Flounder (Paralichthys of olivaceus) Muscle

  • Dong Soo Kim;Chang Hwa Jeong;Young Sun Cho;Yoon Kwon Nam
    • Journal of Aquaculture
    • /
    • v.12 no.1
    • /
    • pp.71-77
    • /
    • 1999
  • The potential utility of injection media (sucrose, PEG, and liposome) was demonstrated for direct gene transfer into olive flounder (Paralichthys olivaceus) muscles. Based on the use of sucrose (final cone. 20%), PEG 8,000 (final cone. 10%) or liposome (twice us of DNA injected), the present injection strategy significantly improved the level of transgene expression as well as persistent duration of expression. The increased amounts of expression in DNA injection with sucrose, PEG, and liposome were as high as from 2.1 to 4.9-folds of conventional TE-based DNA injection. The best result was obtained from injections of liposome-encapsulated DNA in which the expression was detectable at least 32 days after injection when compared to only 8-16 days from TE-based injections.

  • PDF

Liquid Bridge -Mediated Nanotransfer Molding : A New Direct Printing Method

  • Dang, Jeong-Mi;Jo, Bo-Ram;O, Hyeon-Seok;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.85-85
    • /
    • 2010
  • We report a new direct printing method, called liquid-mediated nanotransfer molding (LB-nTM), that uses a polar liquid-mediated transfer process. LB-nTM is based on the direct transfer of various materials from a stamp to a substrate via a liquid- bridge between the stamp and the substrate. This procedure can be adopted in automated printing machines that generate various material patterns with a wide range of feature sizes (as small as 60 nm) on diverse substrates. The patterns have been investigated by scanning electron microscopy(SEM).

  • PDF

Optimization of Nozzle Arrangement in a Liquid Direct Contact Cooling System : Constant Inlet Flowrate Analysis (액체식 직접 접촉 냉각장치의 노즐배열 최적화 : 정풍량 해석)

  • Kim Won-Nyun;Kim Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.402-409
    • /
    • 2006
  • For the design of a liquid direct contact cooling system, thermal and hydraulic analysis has been carried out. Well-known Zukauskas correlations are used to estimate the Nusselt number between the liquid refrigerant columns and the inlet airflow. The inlet air velocity is set at a typical value used in an actual showcase. For a constant column number, the best nozzle arrangement is determined for the maximum heat transfer. Heat transfer increases as the transverse pitch of the refrigerant column decreases. Among all the cases dealt with in the present study, the staggered arrangement with 140-columns of $14{\times}10$ shows the best thermal peformance and the expected temperature drop is $27.8^{\circ}C$. The effect of downstream refrigerant columns on the overall thermal performance is investigated as well.

A Study on the Impact Load Quantification of the Jaw Crusher (쇄석기의 충격하중 정량화에 대한 연구)

  • Hong, Sung Ju;Yang, Hae Jeong
    • Journal of Drive and Control
    • /
    • v.16 no.2
    • /
    • pp.1-7
    • /
    • 2019
  • Jaw crusher is a device that breaks rock collected from mines or quarries to produce aggregates of the size desired by user. A representative method for measuring load is to measure them by attaching force sensors directly to the part where the load is generated. However, the direct method has many limitations such as high-impact loads generation in equipment or space constraints, sensor capacities and costs. Therefore, Transfer Path Analysis (TPA) was used to indirectly measure impact loads by attaching acceleration sensors. In this study, both direct and TPA methods were used to measure the impact load of Jaw crusher. This study finally quantifies the impact of the load generated by the Jaw crusher using direct method and TPA method, and comparing the impact load measured calculated the derive the error rate.

Development of analysis program for direct containment heating

  • Jiang, Herui;Shen, Geyu;Meng, Zhaoming;Li, Wenzhe;Yan, Ruihao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3130-3139
    • /
    • 2022
  • Direct containment heating (DCH) is one of the potential factors leading to early containment failure. DCH is closely related to safety analysis and containment performance evaluation of nuclear power plants. In this study, a DCH prediction program was developed to analyze the DCH loads of containment vessel. The phenomenological model of debris dispersal, metal oxidation reaction, debris-atmospheric heat transfer and hydrogen jet burn was established. Code assessment was performed by comparing with several separate effect tests and integral effect tests. The comparison between the predicted results and experimental data shows that the program can predict the key parameters such as peak pressure, temperature, and hydrogen production in containment well, and for most comparisons the relative errors can be maintained within 20%. Among them, the prediction uncertainty of hydrogen production is slightly larger. The analysis shows that the main sources of the error are the difference of time scale and the oxidation of cavity debris.