• 제목/요약/키워드: Direct inlet

검색결과 126건 처리시간 0.021초

0.4 MW급 가스분사식 배연탈황 흡수탑의 운전 특성 (Operating Characteristics of 0.4 MW-Scale Gas Dispersion Type FGD Absorber)

  • 안희수;김기형;박승수;박광규;김영호
    • 한국대기환경학회지
    • /
    • 제24권4호
    • /
    • pp.415-422
    • /
    • 2008
  • This study was carried out to investigate the effect of operating and design conditions of gas dispersion type of absorber on $SO_2$ removal efficiency. pH difference between upper and lower part of gas dispersing plate of absorber was 0.2, which was relatively low. This was supposed that recirculation capacity of absorbing liquid between froth zone and reaction zone of absorber be increased by oxidation air injection through liquid riser which acted as liquid pump. Test results showed that $SO_2$ removal efficiency was more sensitive than absorber ${\Delta}P$. High $SO_2$ removal even at lower pH resulted from very low concentration of $HSO_3^-$ ion in absorbing liquid because of direct supply of dissolved oxygen into froth zone. 96% of $SO_2$ removal efficiency was obtained under the condition of absorber pH 5.2, flue gas flow rate of $1,530\;Nm^3/hr$, inlet $SO_2$ concentration of 800 ppm, absorber ${\Delta}P$ of 250mmAq. The following equation by a multiple linear regression was obtained to describe the relationship between $SO_2$ removal and operating variables. $$f=1-{\exp}(-1.3939+1.060pH+0.0139{\Delta}P-0.00267G-0.000064SO_2Conc.),\;R^2=0.9719$$

예조건화 기법과 직접모사법을 이용한 추력기 플룸 거동에 관한 연구 (Study on the Thruster Plume Behaviors using Preconditioned Scheme and DSMC Method)

  • 이균호;김수겸;유명종
    • 항공우주기술
    • /
    • 제8권1호
    • /
    • pp.144-153
    • /
    • 2009
  • 일반적으로 노즐 출구 부근에서 준연속체 상태로 방출된 추력기 플룸 유동은 노즐출구에서 멀어질수록 천이영역을 거쳐 자유분자 영역에 도달하기 때문에 희박영역에서의 추력기 플룸 영향을 연구하기 위해서는 광범위한 유동영역의 모델링이 가능한 직접모사법(DSMC)이 주로 사용된다. 본 논문에서는 희박영역에서 소형 단일추진제 추력기의 플룸 거동을 직접모사법을 이용해 수치적으로 예측하는 것이 목적이다. 정확한 결과를 효율적으로 유추하기 위해 예조건화 기법을 노즐 내부 연속체 영역의 해석에 도입하였으며, 이로부터 얻은 노즐 출구의 물성치 결과들을 직접모사법의 유입조건으로 적용하였다. 이렇게 두 기법을 결합하여 사용한 결과, 노즐 출구 부근에서 발생되는 강한 비평형성 및 넓은 후방 유동 영역 등과 같이 희박영역에서 플룸이 가지는 고유의 특성들을 확인할 수 있었다.

  • PDF

희박영역에서 예조건화 연속체기법과 직접모사법을 이용한 소형 추력기 플룸 거동에 관한 연구 (Study on Small Thruster Plume using Preconditioned Continuum Scheme and DSMC Method in Vaccum Area)

  • 이균호;이성남
    • 한국항공우주학회지
    • /
    • 제37권9호
    • /
    • pp.906-915
    • /
    • 2009
  • 일반적으로 노즐 출구 부근에서 준연속체 상태로 방출된 추력기 플룸 유동은 노즐출구에서 멀어질수록 천이영역을 거쳐 자유분자 영역에 도달하기 때문에 진공영역에서의 추력기 플룸 영향을 연구하기 위해서는 광범위한 유동영역의 모델링이 가능한 직접모사법(DSMC)이 주로 사용된다. 본 논문에서는 진공영역에서 소형 단일추진제 추력기의 플룸 거동을 직접모사법을 이용해 수치적으로 예측하는 것이 목적이다. 정확한 결과를 효율적으로 유추하기 위해 예조건화 기법을 노즐 내부 연속체 영역의 해석에 도입하였으며, 이로부터 얻은 노즐 출구의 물성치 결과들을 직접모사법의 유입조건으로 적용하였다. 이렇게 두 기법을 결합하여 사용한 결과, 노즐 출구 부근에서 발생되는 강한 비평형성 및 넓은 후방유동 영역 등과 같이 진공영역에서 플룸이 가지는 고유의 특성들을 확인할 수 있었다.

공동현상을 고려한 커먼레일용 고압 DME 인젝터 노즐의 최적 설계 연구 (Study on the Optimum Design of High Pressure Common-rail DME Injector Nozzle with Consideration of Cavitation)

  • 정수진;박정권;이상인
    • 한국자동차공학회논문집
    • /
    • 제21권1호
    • /
    • pp.99-106
    • /
    • 2013
  • DME (Di-Methyl Ether) is synthetic product that is produced through dehydration of methanol or a direct synthesis from syngas. And it is able to save fossil fuel and reduce pollutants of emission such as PM and $CO_2$. In spite of its advantages it is difficult to design DME fuelled engine system because DME fuel may cause to severely generate cavitation and corrosion in fuel delivery system due to physical properties of DME. Therefore, in this study three-dimensional internal flow characteristics with consideration of cavitation were predicted in the DME injector using diesel and DME fuel. Moving grid technique was employed to describe needle motion and 1-D hydraulic simulation of injector was also simulated to obtain transient needle motion profiles. The results of simulation show that cavitations was generated at the inlet of nozzle near high velocity region both diesel and DME. And mass flow rate of DME is reduced by 4.73% compared to that of diesel at maximum valve lift because cavitation region of DME is much more larger. To increase flow rate of DME injector, internal flow simulation has been conducted to investigate the nozzle hole inner R-cut effect. The flow rates of diesel and DME increase as R-cut increases, and flow coefficient of DME fuel injector was increased by 6.3% on average compared with diesel fuelled injector. Finally, optimum shape of DME injector nozzle is suggested through the comparison of flow coefficient with variation of nozzle hole inner R-cut.

A Bio-fluidic Device for Adaptive Sample Pretreatment and Its Application to Measurements of Escherichia coli Concentrations

  • Choi Won-Jae;Park Je-Kyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권1호
    • /
    • pp.54-60
    • /
    • 2006
  • In this paper, we describe a bio-fluidic device for adaptive sample pretreatment, in order to optimize the conditions under which absorbance assays can be conducted. This device can be successfully applied to the measurement of Escherichia coli (E. coli) concentrations using adaptive dilution, with which the dilution ratio can be adjusted during the dilution. Although many attempts have been previously made to miniaturize complex biochemical analyses at the chip scale, very few sample pretreatment processes have actually been miniaturized or automated at this point. Due to the lack of currently available on-chip pretreatments, analytical instruments tend to suffer from a limited range of analysis. This occasionally hinders the direct and quantitative analysis of specific analyses obtained from real samples. In order to overcome these issues, we exploit two novel strategies: dilution with a programmable ratio, and to-and-fro mixing. The bio-fluidic device consists of a rectangular chamber constructed of poly(dimethylsiloxane) (PDMS). This chamber has four openings, an inlet, an outlet, an air control, and an air vent. Each of the dilution cycles is comprised of four steps: detection, liquid drain, buffer injection, and to-and-fro mixing. When using adaptive sample pretreatment, the range in which E. coli concentrations can be measured is broadened, to an optical density (O.D.) range of $0.3{\sim}30$. This device may prove useful in the on-line monitoring of cell concentrations, in both fermenter and aqueous environments.

하인두암에서의 하부경계 파악을 위한 자기공명영상활영술의 유용성 (The Efficacy of MRI for Evaluation of Inferior Margin of Hypopharyngeal Cancer)

  • 진영완;이동엽;홍남표;송영호;최희석;안회영
    • 대한기관식도과학회지
    • /
    • 제6권1호
    • /
    • pp.7-15
    • /
    • 2000
  • Background and Objectives:Submucosal spread of hypopharyngeal canceris frequently incriminated for the high incidence of local recurrence after resection. Although mucosal spread is better detected by means of direct visualization, submucosal spread is better evaluated by using cross-sectional imaging rather than endoscopy. This study was designed to evaluate the efficacy of MRI in diagnosing involvement of inferior margin of hypopharyngeal cancer. Materials and Method : Eight patients with hypopharyngeal cancer underwent MRI prior to surgery. And postoperative histopathopogic involvement of tumor was compared with the preoperative MRI axial scan. Results : In preoperative MRI findings, involvement of pyriform sinus apex was 6 cases(definitive 5 cases, probable 1 cases), that of esophageal inlet was 1 case(probable), that of cervical esophagus was 1 case(probable). In postoperative histopathologic findings, the results were same. Conclusion : MRI evaluation for patient with hypopharyngeal cancer ensures accurate staging and provides essential information about the tumor involvement of inferior margin. And there is needed to be thin section thickness in evaluation of inferior margin of hypopharyngeal cancer.

  • PDF

GDL을 고려한 고분자전해질형 연료전지 모사 단위 유로 채널에서의 물방울 유동 특성에 대한 실험적인 고찰 (Experimental Investigation of the Water Droplet Dynamics inside the Simulated PEMFC Single Flow Channel with GDL)

  • 김한상;지용휘;인지헌;안지용
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.76-83
    • /
    • 2013
  • Polymer electrolyte membrane fuel cells (PEMFCs) are regarded as a promising alternative to replace the existing automotive power sources. To get high performance and long-term durability for PEMFC systems, novel water management is essential. To this end, a comprehensive understanding of dynamics of the liquid water droplets within an operating PEMFC plays an important role. In this work, direct visualization of dynamic behaviors of the water droplet in the ex situ unit flow channel of a PEMFC including gas diffusion layer (GDL) is carried out as one of the fundamental studies for novel water management. Water droplet dynamics such as the movement and growth of liquid water droplets are mainly presented. Effects of GDL characteristics and inlet air flow rate on the water droplet transport and its removal from the flow channel are also discussed. The data obtained in this study can contribute to build up the fundamental operating strategy including balanced water removal capacity for automotive PEMFC systems.

코안다효과를 이용한 제진기 스크린의 최적설계를 위한 수치적 연구 (A Numerical Study for Optimum Design of Dust Separator Screen Based on Coanda Effect)

  • 윤성민;김용선;신희재;고상철
    • 한국기계가공학회지
    • /
    • 제17권6호
    • /
    • pp.177-185
    • /
    • 2018
  • There is a need to study dust separator screens with good drainage efficiency while effectively filtering suspended solids and other contaminants entering the intake pumping station, the drainage pumping station and the mediation pumping station, the cooling water inlet of the power plant, and the like. In this paper, Numerical studies were conducted for the optimal design of the dust separator screen using the Coanda effect. The shape of the dust separator screen is important, such as the right curvature radius $R_1$ at the top of the dust separator screen and the left curvature radius $R_2$ at the top, h is the height difference and shape between the screen and the accelerating plate, and ${\theta}$ is the inclination angle of the screen. A total of 4 shape factors were set and the effects of Coanda and drainage performance of each element were compared and analyzed, the optimum length and size of each shape element were derived by classifying the shape elements into direct and indirect influences. Finally, it was possible to effectively filter foreign matter by narrowing the screen spacing, and the drainage performance was analyzed and optimized through numerical studies of dust separator screen.

확장형 이중패커를 이용한 지하수 공벽과 내부케이싱의 구간차폐 그라우팅 기술에 대한 연구 (A Study on Grouting Technology Using Expansion Double Packers for Sectional Blocking between Groundwater Borehole and Inner Casing)

  • 조희남;최성욱;박종오;배세달;이병용;최상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제24권1호
    • /
    • pp.35-42
    • /
    • 2019
  • In installation of groundwater wells, grouting materials are injected between the groundwater borehole and the inner casing in order to prevent infiltration of contaminated groundwater from the top soil layers into wells. The injection device of grouting materials is commonly composed of an inlet head device with an expansion packer, a cylinder capable of storing the grouting materials, and an air cylinder. In this work, two types of common grouting materials, silicon and cement materials, were tested for their performances as grouting media. For silicon. silicon was mixed with clay or calcite, and tested for their tensile strength and underwater reactivity. Both silicon-clay and silicon-calcite mixtures had adequate flow and adhesiveness. For cement material, general cement, ultra-rapid harding cement, and natural cement were respectively mixed with three different soil types including coarse-grained granite, fine-grained granite, and gneiss, and direct shearing tests were conducted after hardening. Under grouting depth condition of 30 m, the minimum adhesive strength was greater for weathered gneiss than non-weathered gneiss with its maximum values obtained from the mixtures of ultra rapid-harding cement.

원자로압력용기 노즐부 구속효과를 고려한 파괴인성 평가 (Evaluation of Fracture Toughness considering Constraint Effect of Reactor Pressure Vessel Nozzle)

  • 권형도;이연주;김동학;이도환
    • 한국압력기기공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.71-76
    • /
    • 2019
  • Actual stress distributions in the nozzle of a pressure vessel may not be in plane strain condition, implying that the crack-tip constraint condition may be relaxed in the nozzle. In this paper, a methodology for evaluating the fracture toughness of the ASME Code is presented considering the relaxation of the constraint effect in the nozzle of the reactor pressure vessel. The crack-tip constraint effect is quantified by the T-stress. The equation, which represent the relation between the fracture toughness in the lower constraint condition and the plane strain fracture toughness, is derived using the T-stress. This equation is similar to the method for evaluating the fracture toughness of the Master Curve for low constraint conditions. As a result of evaluating the fracture toughness considering the constraint effect in the reactor inlet, outlet and direct injection nozzles using the proposed equation, it was confirmed that the fracture toughness in the nozzles is higher than the plane strain fracture toughness. Applying the proposed evaluation methodology, it is possible to reflect the relaxation of the constraint effect in the nozzles of the reactor pressure vessel, therefore, the safe operation area on the pressure-temperature limit curve can be prevented from being excessively limited.