• 제목/요약/키워드: Direct contact heat exchanger

검색결과 35건 처리시간 0.022초

Overview of separate effect and integral system tests on the passive containment cooling system of SMART100

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hong Hyun Son;Jin Su Kwon;Hwang Bae;Hyun-Sik Park;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1066-1080
    • /
    • 2024
  • SMART100 has a containment pressure and radioactivity suppression system (CPRSS) for passive containment cooling system (PCCS). This prevents overheating and over-pressurization of a containment through direct contact condensation in an in-containment refueling water storage tank (IRWST) and wall condensation in a CPRSS heat exchanger (CHX) in an emergency cool-down tank (ECT). The Korea Atomic Energy Research Institute (KAERI) constructed scaled-down test facilities, SISTA1 and SISTA2, for the thermal-hydraulic validation of the SMART100 CPRSS. Three separate effect tests were performed using SISTA1 to confirm the heat removal characteristics of SMART100 CPRSS. When the low mass flux steam with or without non-condensable gas is released into an IRWST, the conditions for mitigation of the chugging phenomenon were identified, and the physical variables were quantified by the 3D reconstruction method. The local behavior of the non-condensable gas was measured after condensation inside heat exchanger using a traverse system. Stratification of non-condensable gas occurred in large tank of the natural circulation loop. SISTA2 was used to simulate a small break loss-of-coolant accident (SBLCOA) transient. Since the test apparatus was a metal tank, compensations of initial heat transfer to the material and effect of heat loss during long-term operation were important for simulating cooling performance of SMART100 CPRSS. The pressure of SMART100 CPRSS was maintained below the design limit for 3 days even under sufficiently conservative conditions of an SBLOCA transient.

직접접촉식 빙축열조의 전열특성에 관한 연구 - 빙축열조의 단열영향을 중심으로 - (An Experimental Study on the Thermal Characteristics of Ice Storage Tank - Focusing on the Adiabatic Effects of Ice Storage Tank -)

  • 이채문;박정원;조남철;박상록;김일겸;김동춘;김영기;임장순
    • 태양에너지
    • /
    • 제17권2호
    • /
    • pp.75-89
    • /
    • 1997
  • 동적형(Dynamic type) 빙축열시스템의 빙축열조에서 단열조건과 비단열조건인 경우 각각 얼음충진율(Ice Packing Factor), 분산유체의 온도 및 유량의 변화에 따른 실험을 수행하였다. 실험시간이 경과함에 따라 빙축열조의 수직방향으로 온도성층화가 나타났으며 분산유체의 유입온도가 높고 유입유량이 많을수록 상부영역에서 온도분포는 크게 변화하였고 온도성층화에 도달하는 시간도 단축되었다. 또한 얼음충진율이 작은 경우가 온도성층화를 이루는 시간이 짧았고 상하부 온도차가 급격히 커진 것 알 수 있었다. 그리고 단열의 경우가 비단열의 경우보다 모든 조건하에서 조금 높은 온도분포를 나타내었으며 온도성층화에 소요되는 시간도 조금 단축되었다. 빙축열조내의 수직방향의 평균온도 상승은 얼음충진율이 낮고 유량이 많을수록 커졌으며 총방열에너지에 대한 잠열에너지의 비($E_{\lambda}/E_[tot}$)는 약 80%정도로 나타났다. 또한 유입온도가 높고 유량이 많을수록 잠열에너지의 방출이 빨리 나타났다.

  • PDF

반도체 클린룸용 수증기 응축식 에어와셔 시스템의 성능평가 (An Experiment on Performance Evaluation of a Vapor Condensation Type Air Washer System for Semiconductor Clean Rooms)

  • 여국현;박상태;유경훈;손승우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.442-447
    • /
    • 2006
  • In semiconductor manufacturing clean rooms, it becomes important to remove airborne molecular contaminants as well as particulate contaminant in outdoor air introduced into clean rooms. One suitable control technique for these chemical contaminants is air washing by water in an outdoor air handling unit. In order to enhance the removal efficiency of chemical contaminants the effect of adding a heating and humidifying process before an air washer was examined.

  • PDF

초저온 액화 천연 가스용 기화기 핀의 승온 특성에 관한 수치 해석 (Numerical Analysis on the Increasing Temperature Characteristics of Vaporizer Fin for Liquefied Natural Gas with Super Low Temperature)

  • 이중섭;공태우;이효덕;정효민;정한식
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.81-87
    • /
    • 2005
  • This study is numerical analysis on the increasing temperature characteristics of vaporizer fin for liquefied natural gas with super low temperature. Existing LNG vaporizers use the direct contact heat transfer mode where the extreme super low temperature LNG of $-162^{\circ}C$ flows inside of the tubes and about $20^{\circ}C$air flows on outside of the fin. Recently, the vaporizers with great enhanced performance compared to conventional type have been developed to fulfill these requirements. The vaporizing characteristic of LNG vaporizer with air as heat source has a fixed iced. These characteristic cause a low efficiency in vaporizer, total plant cost and installing space can be increased. The vaporizing characteristics of LNG via heat exchanger with air are analytically studied for an air heating type vaporizer. This study is intended to supply the design data for the domestic fabrication of the thickness and angle vaporizer fin. Governing conservation equations for mass, momentum and energy are solved by STAR-CD based on an finite volume method and SIMPLE algorithm. Calculation parameter is fin thickness, setup angle and LNG temperature. If the vaporization performance of the early stage and late stage of operating is considered, the case of ${\phi}=90^{\circ}$ was very suitable. In this paper was estimated that the heat transfer was most promoted in case of THF=2mm.

  • PDF

태양열 이용을 위한 직접접촉식열교환기(DCHX)의 작동에 관한 실험적 연구 (An Experimental Study on the Performance of a Direct Contact Heat Exchanger(DCHX) for Solar Application)

  • 현영진;현준호;천원기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.73-81
    • /
    • 2004
  • 태양열의 이용에 있어 직접접촉식 열교환기(DCHX)는 여러 가지 잇점을 제공한다. 그중에서도 제일 부각되는 것은 폐쇄형 열교환기의 대체에 다른 경비 절약과 작은 온도차에서도 열교환이 가능한 뛰어난 열성능일 것이다. 본 연구는 액-액 타입의 직접접촉식 열교환기에 대한 열성능 실측을 통하여 직접 접촉 열교환에 대한 이해를 증진하고 아울러 태양열에의 적용성을 평가하고자 하였다. 실측 시스템은 집열기와 펌프 그리고 직접접촉식 열교환기로 구성되어 있는데 작동유체의 종류에 따라 서로 다른 두 가지 방법에 의해 열교환기 내로 유입되도록 하였다. 작동유체로는 Texatherm 46과 물이 사용되었는데 이는 이들 유체가 서로 전이지 않고 높은 온도$(<150^{\circ})$에서도 화학적으로도 안전하며 열적으로도 비교적 양호한 성능을 가지고 있기 때문이다 본 연구는 실측을 통해 열교환기 내에서의 미미한 열성층화 현상에 대한 메카니즘을 확인하였으며 아울러 열교환기의 작동유체에 따라 작동의 안정성과 열적 성능(11% 차이)이 다르게 나타날 수 있음을 보여주고 있다.